comparison src/g23m-aci/bat/bat_app.c @ 162:53929b40109c

src/g23m-aci: initial import from TCS3.2/LoCosto
author Mychaela Falconia <falcon@freecalypso.org>
date Tue, 11 Oct 2016 02:02:43 +0000
parents
children
comparison
equal deleted inserted replaced
161:4557e2a9c18e 162:53929b40109c
1 /*
2 +-----------------------------------------------------------------------------
3 | Project :
4 | Modul : BAT
5 +-----------------------------------------------------------------------------
6 | Copyright 2005 Texas Instruments Berlin, AG
7 | All rights reserved.
8 |
9 | This file is confidential and a trade secret of Texas
10 | Instruments Berlin, AG
11 | The receipt of or possession of this file does not convey
12 | any rights to reproduce or disclose its contents or to
13 | manufacture, use, or sell anything it may describe, in
14 | whole, or in part, without the specific written consent of
15 | Texas Instruments Berlin, AG.
16 +-----------------------------------------------------------------------------
17 | Purpose : This Modul holds the functions
18 | for the binary AT command library at APPlication side
19 +-----------------------------------------------------------------------------
20 */
21 #ifndef _BAT_APP_C_
22 #define _BAT_APP_C_
23
24 /*==== INCLUDES =============================================================*/
25 #include <string.h>
26 #include <math.h>
27
28 #include "typedefs.h"
29 #include "gdd.h"
30 #include "gdd_sys.h"
31 #include "l2p_types.h"
32 #include "l2p.h"
33 #include "bat.h"
34 #include "bat_ctrl.h"
35 #include "bat_intern.h"
36
37 /*==== DEFINES==== ==========================================================*/
38 #define BAT_NOT_INITIALIZED FALSE
39 #define BAT_INITIALIZED TRUE
40
41
42 /*==== GLOBAL VARS ==========================================================*/
43
44
45 /*==== EXTERN VARS ==========================================================*/
46
47 LOCAL void cvt_to_str (unsigned char input_num, char *num_str)
48 {
49 int i;
50 memset(num_str, 0, 3);
51
52 for (i = 0; i < 3; i++)
53 {
54 if(input_num/pow(10,i) >0)
55 {
56 *(num_str+(2-i)) = (char)(input_num/pow(10,i))+'0';
57 }
58 }
59 return;
60 }
61
62 /* create dummy functions to make the interface alligned with BT */
63 GLOBAL T_BAT_return bat_init (void *mem, unsigned char num)
64 {
65 BAT_TRACE_FUNCTION ("bat_init()");
66 return (BAT_OK);
67 }
68
69 GLOBAL T_BAT_return bat_deinit (void)
70 {
71 BAT_TRACE_FUNCTION ("bat_deinit()");
72 return (BAT_OK);
73 }
74
75 /*
76 +----------------------------------------------------------------------------+
77 | PROJECT : MODULE : BINARY AT COMMAND LIBRARY |
78 | STATE : code ROUTINE : bat_new |
79 +----------------------------------------------------------------------------+
80 PURPOSE :
81 This function is used to create a new instance of BAT Lib. It provides BAT Lib
82 the following information: an output parameter to pass back the instance handle
83 to the application; a pointer to the memory, which is allocated by the application
84 framework, for internal maintenance; the number of clients to maintain; the
85 appropriate configuration, a signal call back function pointer
86 and an unsolicited result code call back function pointer.
87 */
88
89 GLOBAL T_BAT_return bat_new (T_BAT_instance *inst_hndl,
90 void *mem,
91 unsigned char num,
92 T_BAT_config *config,
93 void (*instance_signal_cb)(T_BAT_signal signal))
94 {
95 int i;
96 T_BAT_client_maintain *clnt_mt = NULL;
97 T_BAT_instance_maintain *inst_mt = NULL;
98 CHAR sem_str[] = "SEM_BAT000"; /* long enough to hold "SEM_BATxxx" */
99
100 U32 mem_l2p;
101
102 BAT_TRACE_FUNCTION ("bat_new()");
103
104 /* check if the parameters are correct */
105 if ((mem EQ NULL) OR (num > BAT_CONTROL_CHANNEL) OR
106 (config EQ NULL) OR (instance_signal_cb EQ NULL))
107 {
108 BAT_TRACE_ERROR ("bat_new(): input parameter incorrect!");
109 return (BAT_ERROR);
110 }
111 /* init allocated memory */
112 memset(mem, 0, num * BAT_CLIENT_SIZE + BAT_INSTANCE_SIZE);
113
114 /* init global params */
115 if (bat_init_global_params())
116 {
117 return (BAT_ERROR);
118 }
119
120 /* get the free slot to store the instance pointer */
121 if (bat_get_new_instance(inst_hndl) NEQ BAT_OK)
122 {
123 return (BAT_ERROR);
124 }
125
126 /* init the instance maintainance data */
127 inst_mt = (T_BAT_instance_maintain *)mem;
128
129 /* init semaphore */
130 cvt_to_str(*inst_hndl, &sem_str[7]);
131 inst_mt->sem_BAT = gdd_sys_sem_open(sem_str, 1);
132
133 if (inst_mt->sem_BAT EQ (-1))
134 {
135 BAT_TRACE_ERROR("canīt open semaphore \"SEM_BAT\"");
136 return (BAT_ERROR);
137 }
138
139 /* init the pointer in the pointer list */
140 bat_init_instance_pointer (*inst_hndl, inst_mt);
141
142 inst_mt->instance_signal_cb = instance_signal_cb;
143 inst_mt->unsolicited_result_cb = NULL;
144 inst_mt->max_client_num = num;
145 inst_mt->config = config;
146 bat_change_instance_state(inst_mt,BAT_INSTANCE_IDLE);
147 bat_change_buffer_state(inst_mt, BAT_BUF_EMPTY);
148
149 BAT_TRACE_EVENT_P1 ("bat_new(): BAT INST add is: %04X", mem);
150
151 /* init the clients */
152 for (i = 0; i < num; i ++)
153 {
154 clnt_mt = (T_BAT_client_maintain *)((U32)sizeof(T_BAT_client_maintain)*i + (U32)inst_mt +
155 (U32)sizeof (T_BAT_instance_maintain));
156 BAT_TRACE_EVENT_P2 ("bat_new(): BAT CLNT %d ' add is: %04X", i, clnt_mt);
157
158 bat_change_client_state(clnt_mt, BAT_CLIENT_IDLE);
159 }
160
161 /* configure the L2P */
162 mem_l2p = (U32)inst_mt+sizeof(T_BAT_instance_maintain) + num*sizeof(T_BAT_client_maintain);
163 BAT_TRACE_EVENT_P1("bat_new(): The address passed to L2P is 0x%4x", mem_l2p);
164 L2P_Configure(*inst_hndl, (void*)((U32)inst_mt+sizeof(T_BAT_instance_maintain)+num*sizeof(T_BAT_client_maintain)),
165 config->l2p.protocol_id, (U16)(config->adapter.cap.dio_cap.mtu_size), bat_l2p_get_tx_buffer,
166 bat_l2p_get_rx_buffer, bat_l2p_get_next_buf_seg, bat_l2p_send_frame, bat_l2p_message_rxd);
167
168 /* call GDD to create the connection, if ERROR is returned the app should call bat_new later*/
169 if ((config->adapter.gdd_if.gdd_connect(GDD_INST_BAT, (T_GDD_CON_HANDLE*)&(inst_mt->con_handle),
170 &(config->adapter.cap), bat_gdd_receive_data_cb,
171 bat_gdd_signal_cb))NEQ GDD_OK)
172 {
173 BAT_TRACE_ERROR ("bat_new(): Error returned from gdd_connect().");
174 bat_deinit_instance_pointer(*inst_hndl);
175 L2P_Remove (*inst_hndl);
176 return (BAT_ERROR);
177 }
178
179 /* BAT Lib is awaiting 2 confirmations. One from GDD and one from ACI, the confirmations will be handled in the cbs */
180
181 return (BAT_OK);
182 }
183
184 /*
185 +----------------------------------------------------------------------------+
186 | PROJECT : MODULE : BINARY AT COMMAND LIBRARY |
187 | STATE : code ROUTINE : bat_delete |
188 +----------------------------------------------------------------------------+
189 PURPOSE :
190 This function is used to delete the BAT Lib instance created by function
191 bat_new().The provided callback function is used to inform the application of
192 the finial result. If the application receives an indication of successfully
193 deleting of the BAT Lib instance, the memory allocated to this instance can
194 be freed by the application. Please note that the application should call
195 bat_close() to close all the clients before deleting the BAT Lib instance.
196 */
197
198 GLOBAL T_BAT_return bat_delete (T_BAT_instance inst_hndl)
199 {
200 T_BAT_instance_maintain *inst_mt = NULL;
201
202 BAT_TRACE_FUNCTION ("bat_delete()");
203
204 /* check if inst_hndl is valid */
205 if (inst_hndl EQ BAT_INVALID_INSTANCE_HANDLE)
206 {
207 return (BAT_ERROR);
208 }
209
210 /* the instance can not be deleted before all clients are closed */
211 if (bat_check_if_all_clients_are_closed(inst_hndl) EQ FALSE)
212 {
213 return (BAT_ERROR);
214 }
215
216 /* get instance from instance handle */
217 if (bat_get_instance_from_instance_handle (inst_hndl, &inst_mt) EQ BAT_ERROR)
218 {
219 return (BAT_ERROR);
220 }
221
222 /* call GDD to inform the close of an instance */
223 if (inst_mt->config->adapter.gdd_if.gdd_disconnect((T_GDD_CON_HANDLE)(inst_mt->con_handle)) NEQ GDD_OK)
224 {
225 BAT_TRACE_ERROR ("bat_delete(): Error returned from gdd_connect(), instance cannot be deleted.");
226 return (BAT_ERROR);
227 }
228 bat_change_instance_state(inst_mt,BAT_INSTANCE_IDLE);
229
230 /* remove the l2p maintainance data */
231 L2P_Remove (inst_hndl);
232 /*BAT deinit the instance*/
233 bat_deinit_instance_pointer (inst_hndl);
234
235 if (inst_mt->sem_BAT NEQ (-1))
236 {
237 gdd_sys_sem_close(inst_mt->sem_BAT);
238 }
239
240 /* deinit the BAT Lib if the last instance has been deleted */
241 bat_deinit_global_params();
242
243 return (BAT_OK);
244 }
245
246 /*
247 +----------------------------------------------------------------------------+
248 | PROJECT : MODULE : BINARY AT COMMAND LIBRARY |
249 | STATE : code ROUTINE : bat_open |
250 +----------------------------------------------------------------------------+
251 PURPOSE :
252 This function is used to open a new binary AT command client path. This
253 function passes a unique client handle to the application by the output
254 parameter clnt_hndl. This client handle is used by bat_send(), bat_close()
255 and bat_cntrl().The bat_open() function is re-entrant and can be
256 called in serial within one instance.
257 */
258
259 GLOBAL T_BAT_return bat_open( T_BAT_instance instance,
260 T_BAT_client *clnt_hndl,
261 int(*response_cb)( T_BAT_client,T_BAT_cmd_response*),
262 void (*signal_cb)( T_BAT_client, T_BAT_signal))
263 {
264 T_BAT_client_maintain *clnt_mt = NULL;
265 T_BAT_instance_maintain *inst_mt = NULL;
266 T_BAT_return ret = BAT_ERROR;
267 T_BATC_signal ctrl_sig;
268 T_BATC_open_client param;
269
270 BAT_TRACE_FUNCTION ("bat_open()");
271
272 /* find the correct instance */
273 if (bat_get_instance_from_instance_handle (instance, &inst_mt) EQ BAT_ERROR)
274 {
275 return (BAT_ERROR);
276 }
277
278 /* bat_open should be called after bat instance is created */
279 if (inst_mt->instance_state < BAT_INSTANCE_READY)
280 {
281 BAT_TRACE_EVENT_P1 ("ERROR: the instance state is %d", inst_mt->instance_state);
282 return (BAT_ERROR);
283 }
284
285 /* check if one more client can be created */
286 if (bat_get_new_client(instance, clnt_hndl) EQ BAT_ERROR)
287 {
288 return (BAT_ERROR);
289 }
290
291 /* set the necessary states before sending the data to BAT ACI, this is bec it can
292 happen that the callback is used before function bat_send_ctrl_data() returns */
293 if (bat_init_new_client (*clnt_hndl, response_cb, signal_cb) EQ BAT_ERROR)
294 {
295 return (BAT_ERROR);
296 }
297
298 if (bat_get_client_from_client_handle(*clnt_hndl, &clnt_mt) EQ BAT_ERROR)
299 {
300 return (BAT_ERROR);
301 }
302
303 bat_change_client_state(clnt_mt, BAT_CLIENT_ACTIVATING);
304
305 param.client_id = (U32)(GET_CLNT_ID_FROM_CLNT_HANDLE(*clnt_hndl));
306 ctrl_sig.ctrl_params = BATC_OPEN_CLIENT;
307 ctrl_sig.params.ptr_open_client = &param;
308
309 /* send control data to BAT ACI */
310 ret = bat_send_ctrl_data(instance, &ctrl_sig);
311
312 switch (ret)
313 {
314 case (BAT_BUSY_RESOURCE):
315 {
316 /* instance state shows that the bat_open() call receives Busy */
317 bat_change_instance_state(inst_mt, BAT_INSTANCE_BUSY);
318 clnt_mt->client_state = BAT_CLIENT_IDLE;
319 clnt_mt->signal_cb = NULL;
320 clnt_mt->response_cb = NULL;
321 break;
322 }
323 case (BAT_ERROR):
324 {
325 /* change back the necessary states if error happens */
326 bat_change_client_state(clnt_mt, BAT_CLIENT_IDLE);
327 clnt_mt->signal_cb = NULL;
328 clnt_mt->response_cb = NULL;
329 break;
330 }
331 case (BAT_OK):
332 default:
333 {
334 break;
335 }
336 }
337 return (ret);
338 }
339
340 /*
341 +----------------------------------------------------------------------------+
342 | PROJECT : MODULE : BINARY AT COMMAND LIBRARY |
343 | STATE : code ROUTINE : bat_uns_open |
344 +----------------------------------------------------------------------------+
345 PURPOSE :
346 This function is used to open a path to receive unsolicited result code.
347 This function passes a unique client handle to the application by the output
348 parameter client. This client handle is used by bat_close()and bat_cntrl().
349 */
350
351 GLOBAL T_BAT_return bat_uns_open (T_BAT_instance instance,
352 T_BAT_client *client,
353 int(*unsolicited_result_cb)( T_BAT_client client, T_BAT_cmd_response *response))
354 {
355 T_BAT_instance_maintain *inst_mt = NULL;
356
357 BAT_TRACE_FUNCTION ("bat_uns_open()");
358
359 /* find the correct instance */
360 if (bat_get_instance_from_instance_handle (instance, &inst_mt) EQ BAT_ERROR)
361 {
362 return (BAT_ERROR);
363 }
364
365 /* this func should be called after bat instance is created */
366 if (inst_mt->instance_state < BAT_INSTANCE_READY)
367 {
368 BAT_TRACE_EVENT_P1 ("ERROR: the instance is not yet initialized! It's state is",
369 inst_mt->instance_state);
370 return (BAT_ERROR);
371 }
372
373 inst_mt->unsolicited_result_cb = unsolicited_result_cb;
374 *client = MAKE_UNS_CLNT_HNDL(instance);
375
376 return (BAT_OK);
377 }
378
379
380 /*
381 +----------------------------------------------------------------------------+
382 | PROJECT : MODULE : BINARY AT COMMAND LIBRARY |
383 | STATE : code ROUTINE : bat_close |
384 +----------------------------------------------------------------------------+
385 PURPOSE :
386 This function is used to close a binary AT command channel. This closing
387 process includes closing of the connection to the modem. If the close process
388 has been successfully performed, BAT Lib will call the signal callback
389 function provided by bat_open() on the application side to indicate. The
390 application can delete the BAT Lib instance only after successfully closing
391 all the clients by calling bat_close().
392 */
393
394 GLOBAL T_BAT_return bat_close (T_BAT_client clnt_hndl)
395 {
396 T_BAT_instance_maintain *inst_mt = NULL;
397 T_BAT_client_maintain *clnt_mt = NULL;
398 T_BATC_signal ctrl_sig;
399 T_BATC_close_client param;
400 T_BAT_return reslt = BAT_ERROR;
401
402 BAT_TRACE_FUNCTION ("bat_close()");
403
404 if (bat_get_instance_from_instance_handle(GET_INST_HNDL_FROM_CLNT_HANDLE(clnt_hndl), &inst_mt))
405 {
406 return (BAT_ERROR);
407 }
408
409 /* if the channel to close is unsolicited code channel */
410 if ((GET_CLNT_ID_FROM_CLNT_HANDLE(clnt_hndl) EQ BAT_BROADCAST_CHANNEL))
411 {
412 inst_mt->unsolicited_result_cb = NULL;
413 /* if there is still data in the buffer for this channel, just ignore the data and empty the buffer */
414 if ((inst_mt->buffer.buf_st EQ BAT_BUF_FILLED) AND (inst_mt->buffer.dest EQ clnt_hndl))
415 {
416 bat_change_buffer_state(inst_mt, BAT_BUF_EMPTY);
417 inst_mt->config->adapter.gdd_if.gdd_signal_ready_rcv ((T_GDD_CON_HANDLE)(inst_mt->con_handle));
418 }
419 return (BAT_OK);
420 }
421
422 /* If the channel to close is a normal client channel */
423 if (bat_get_client_from_client_handle(clnt_hndl, &clnt_mt) OR
424 clnt_mt->client_state < BAT_CLIENT_ACTIVATING)
425 {
426 BAT_TRACE_ERROR ("ERROR: parameter wrong or BAT client is not yet open.");
427 return (BAT_ERROR);
428 }
429
430 param.client_id = GET_CLNT_ID_FROM_CLNT_HANDLE(clnt_hndl);
431
432 ctrl_sig.ctrl_params = BATC_CLOSE_CLIENT;
433 ctrl_sig.params.ptr_close_client = &param;
434
435 /* send control data to BAT ACI */
436 reslt = bat_send_ctrl_data(GET_INST_HNDL_FROM_CLNT_HANDLE(clnt_hndl), &ctrl_sig);
437
438 /* change back the necessary states if GDD busy */
439 switch (reslt)
440 {
441 case (BAT_BUSY_RESOURCE):
442 {
443 bat_change_client_state(clnt_mt, BAT_CLIENT_BUSY);
444 return (BAT_BUSY_RESOURCE);
445 }
446 case (BAT_ERROR):
447 {
448 return (BAT_ERROR);
449 }
450 case (BAT_OK):
451 {
452 break;
453 }
454 }
455
456 /* client state is now changed to Idle, the close function always performs, no asynchronized signal */
457 bat_change_client_state(clnt_mt, BAT_CLIENT_IDLE);
458
459 /* if the buffer is filled with data for this client, free it and send a ready signal to GDD */
460 if ((inst_mt->buffer.buf_st EQ BAT_BUF_FILLED) AND (inst_mt->buffer.dest EQ clnt_hndl))
461 {
462 bat_change_buffer_state(inst_mt, BAT_BUF_EMPTY);
463 inst_mt->config->adapter.gdd_if.gdd_signal_ready_rcv ((T_GDD_CON_HANDLE)(inst_mt->con_handle));
464 }
465
466 return (BAT_OK);
467 }
468
469 /*
470 +----------------------------------------------------------------------------+
471 | PROJECT : MODULE : BINARY AT COMMAND LIBRARY |
472 | STATE : code ROUTINE : bat_close |
473 +----------------------------------------------------------------------------+
474 PURPOSE :
475 This function is used to send a BAT command. The final result is received
476 asynchronously by response_cb().
477 */
478
479 GLOBAL T_BAT_return bat_send (T_BAT_client clnt_hndl, T_BAT_cmd_send *cmd)
480 {
481 T_BAT_client_maintain *clnt_mt = NULL;
482 T_BAT_return ret = BAT_ERROR;
483
484 BAT_TRACE_FUNCTION ("bat_send()");
485
486 /* find the client */
487 if (bat_get_client_from_client_handle(clnt_hndl, &clnt_mt) NEQ BAT_OK)
488 {
489 BAT_TRACE_EVENT_P1("bat_send(): unknown client handle %d", clnt_hndl);
490 return (BAT_ERROR);
491 }
492
493 if (clnt_mt->client_state NEQ BAT_CLIENT_READY)
494 {
495 TRACE_EVENT_P1("bat_send(): client is not in state READY, but in %d", clnt_mt->client_state);
496 return (BAT_ERROR);
497 }
498
499 if (cmd EQ NULL)
500 {
501 TRACE_EVENT("bat_send(): cmd EQ NULL");
502 return (BAT_ERROR);
503 }
504
505 bat_change_client_state(clnt_mt, BAT_CLIENT_SENDING);
506 /* send the data (get buffer, fill buffer and send) */
507 ret = bat_send_cmd_data(clnt_hndl, cmd);
508
509 switch (ret)
510 {
511 case (BAT_BUSY_RESOURCE):
512 {
513 bat_change_client_state(clnt_mt, BAT_CLIENT_BUSY);
514 break;
515 }
516 case (BAT_ERROR):
517 {
518 bat_change_client_state(clnt_mt, BAT_CLIENT_READY);
519 break;
520 }
521 default:
522 {
523 break;
524 }
525 }
526 return (ret);
527 }
528
529 /*
530 +----------------------------------------------------------------------------+
531 | PROJECT : MODULE : BINARY AT COMMAND LIBRARY |
532 | STATE : code ROUTINE : bat_close |
533 +----------------------------------------------------------------------------+
534 PURPOSE :
535 This function is used to send control information, which is not directly
536 related to a binary command request or response, to the BAT library. E.g.
537 telling the BAT Lib to stop the currently running BAT command or to inform
538 the BAT Lib that the application is no longer at BAT_BUSY_RESOURCE state,
539 but is able to receive more data.
540 */
541
542 GLOBAL T_BAT_return bat_ctrl (T_BAT_client clnt_hndl, T_BAT_ctrl *ctrl)
543 {
544 T_BAT_instance_maintain *inst_mt = NULL;
545 T_BAT_client_maintain *clnt_mt = NULL;
546 T_BATC_signal ctrl_sig;
547 T_BATC_abort_cmd param;
548 T_BAT_return ret = BAT_ERROR;
549
550 BAT_TRACE_FUNCTION ("bat_ctrl()");
551
552 /* check the ctrl param */
553 if (ctrl EQ NULL)
554 {
555 return (BAT_ERROR);
556 }
557
558 /* get the correct instance */
559 if (bat_get_instance_from_instance_handle (GET_INST_HNDL_FROM_CLNT_HANDLE(clnt_hndl), &inst_mt))
560 {
561 return (BAT_ERROR);
562 }
563
564 /* abort the running cmd */
565 if (ctrl->event EQ BAT_ABORT)
566 {
567 /* get the correct client */
568 if (bat_get_client_from_client_handle (clnt_hndl, &clnt_mt))
569 {
570 return (BAT_ERROR);
571 }
572
573 if (clnt_mt->client_state < BAT_CLIENT_SENDING)
574 {
575 BAT_TRACE_ERROR ("bat_ctrl(): No running cmd to abort.");
576 return (BAT_ERROR);
577 }
578
579 /* set the abort cmd */
580 param.client_id = GET_CLNT_ID_FROM_CLNT_HANDLE(clnt_hndl);
581 ctrl_sig.ctrl_params = BATC_ABORT_CMD;
582 ctrl_sig.params.ptr_abort_cmd = &param;
583
584 ret = bat_send_ctrl_data(GET_INST_HNDL_FROM_CLNT_HANDLE(clnt_hndl), &ctrl_sig);
585
586 switch (ret)
587 {
588 case (BAT_BUSY_RESOURCE):
589 {
590 /* change back the client state if the command can not be aborted */
591 bat_change_client_state(clnt_mt, BAT_CLIENT_SENDING_AND_BUSY);
592 break;
593 }
594 case (BAT_ERROR):
595 {
596 BAT_TRACE_ERROR ("bat_ctrl(): sending of ctrl data FAILED!");
597 break;
598 }
599 default:
600 {
601 break;
602 }
603 }
604 return (ret);
605 }
606
607 /* this is a ready signal */
608 if (ctrl->event EQ BAT_APP_READY_RESOURCE)
609 {
610 if ((inst_mt->buffer.buf_st EQ BAT_BUF_FILLED) AND (inst_mt->buffer.dest EQ clnt_hndl))
611 {
612 BAT_TRACE_EVENT("bat_ctrl(): Ready signal received, buffered data will be sent!");
613
614 /* handle the case when the buffer is filled with unsolicited code */
615 if ((clnt_hndl EQ MAKE_UNS_CLNT_HNDL(GET_INST_HNDL_FROM_CLNT_HANDLE(clnt_hndl))))
616 {
617 if (inst_mt->unsolicited_result_cb (clnt_hndl, &(inst_mt->buffer.rsp)) NEQ BAT_BUSY_RESOURCE)
618 {
619 bat_change_buffer_state(inst_mt, BAT_BUF_EMPTY);
620
621 inst_mt->config->adapter.gdd_if.gdd_signal_ready_rcv ((T_GDD_CON_HANDLE)(inst_mt->con_handle));
622 BAT_TRACE_EVENT("bat_ctrl(): Buffer sent to APP and the ready signal sent to GDD!");
623 }
624 return (BAT_OK);
625 }
626 else /* signal the GDD that the BAT Lib is able to receive more data */
627 {
628 /* get the correct client */
629 if (bat_get_client_from_client_handle (clnt_hndl, &clnt_mt))
630 {
631 return (BAT_ERROR);
632 }
633 if (clnt_mt->response_cb(clnt_hndl, &(inst_mt->buffer.rsp)) NEQ BAT_BUSY_RESOURCE)
634 {
635 bat_change_buffer_state(inst_mt, BAT_BUF_EMPTY);
636 bat_change_client_state(clnt_mt, BAT_CLIENT_READY);
637
638 inst_mt->config->adapter.gdd_if.gdd_signal_ready_rcv ((T_GDD_CON_HANDLE)(inst_mt->con_handle));
639 BAT_TRACE_EVENT("bat_ctrl(): Buffer sent to APP and the ready signal sent to GDD!");
640 }
641 return (BAT_OK);
642 }
643 }