FreeCalypso > hg > fc-magnetite
diff cdg-hybrid/sap/8010_135_sn_sap.pdf @ 212:e7a67accfad9
cdg-hybrid cdginc headers created
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Fri, 14 Oct 2016 21:52:58 +0000 |
parents | |
children |
line wrap: on
line diff
--- /dev/null Thu Jan 01 00:00:00 1970 +0000 +++ b/cdg-hybrid/sap/8010_135_sn_sap.pdf Fri Oct 14 21:52:58 2016 +0000 @@ -0,0 +1,282 @@ +;******************************************************************************** +;*** File : 8010_135_sn_sap.pdf +;*** Creation : Wed Mar 11 09:57:49 CST 2009 +;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 +;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 +;******************************************************************************** +;*** Document Type : Service Access Point Specification +;*** Document Name : 8010_135_sn_sap +;*** Document No. : 8010.135.04.012 +;*** Document Date : 2004-06-08 +;*** Document Status: APPROVED +;*** Document Author: rpk +;******************************************************************************** + + + +PRAGMA SRC_FILE_TIME "Thu Nov 29 09:27:14 2007" +PRAGMA LAST_MODIFIED "2004-06-08" +PRAGMA ID_AND_VERSION "8010.135.04.012" +PRAGMA PREFIX SN ; Prefix for this document +PRAGMA ALLWAYS_ENUM_IN_VAL_FILE YES ; Enumeration values in value file +PRAGMA ENABLE_GROUP NO ; Enable h-file grouping +PRAGMA COMPATIBILITY_DEFINES NO ; Compatible to the old #defines + + + +CONST MAX_UL_PDU 255 ; Max number of unconfirmed PDUs transferred between RATs (in SN_GET_PENDING_PDU_CNF). +EXTERN CONST @p_8010_137_nas_include - SIZE_NSAPI@ SIZE_NSAPI ; Maximum NSAPI array index for SN_GET_PENDING_PDU_CNF + + + +VALTAB VAL_establish +VAL 0 ACTIVE_ESTABLISHMENT "SNDCP shall send LL_ESTABLISH_REQ" +VAL 1 PASSIVE_ESTABLISHMENT "SNDCP shall wait for LL_ESTABLISH_IND" + + + + +VAR list_len "Octet count of data in all descriptors" S + + +VAR first "Pointer to first descriptor in list" L + + +VAR dl_sequence_number "Sequence number of last unacknowledged downlink PDU (used by the network)" B + + +VAR establish "" B + +VAL @p_8010_135_sn_sap - VAL_establish@ + +VAR receive_no "Receive NPDU number" B + + +VAR dti_neighbor "DTI neighbor entity name." L + + + + + +COMP desc_list2 "DTI parameters" +{ + list_len ; Octet count of data in all descriptors + first ; Pointer to first descriptor in list +} + + + +COMP ul_pdus "Sequence number and descriptor list handles pr. NSAPI" +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network Service Access Point Identifier + dl_sequence_number ; Sequence number of last unacknowledged downlink PDU (used by the network) + desc_list2 PTR [0 .. MAX_UL_PDU] ; List of unconfirmed uplink PDUs +} + + + +COMP receive_no_list "Ssequence numbers and MEM handles pr. NSAPI" +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer Service Access Point Identifier + receive_no ; Receive NPDU number +} + + + + + + +; SN_ACTIVATE_CNF 0x8000409E +; SN_ACTIVATE_REQ 0x8000009E +; SN_DEACTIVATE_CNF 0x8002409E +; SN_DEACTIVATE_REQ 0x8001009E +; SN_GET_PENDING_PDU_CNF 0x8003409E +; SN_GET_PENDING_PDU_REQ 0x8002009E +; SN_MODIFY_CNF 0x8004409E +; SN_MODIFY_REQ 0x8003009E +; SN_STATUS_IND 0x8005409E +; SN_SEQUENCE_REQ 0x8004009E +; SN_SEQUENCE_CNF 0x8006409E +; SN_COUNT_REQ 0x8005009E +; SN_COUNT_CNF 0x8008409E +; SN_DTI_REQ 0x8006009E +; SN_DTI_CNF 0x8009409E + + + +PRIM SN_ACTIVATE_CNF 0x8000409E +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier + EXTERN @p_8010_137_nas_include - comp_params@ comp_params ; Compression parameters +} + + + + + + +PRIM SN_ACTIVATE_REQ 0x8000009E +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier + EXTERN @p_8010_152_ps_include - sapi@ sapi ; LLC service access point identifier + EXTERN @p_8010_152_ps_include - radio_prio@ radio_prio ; Radio priority + EXTERN @p_8010_152_ps_include - qos_r97@ qos_r97 AS snsm_qos ; Peak throughput and other qos + establish ; Establish request + EXTERN @p_8010_137_nas_include - comp_params@ comp_params ; Compression parameters + EXTERN @p_8010_152_ps_include - pkt_flow_id@ pkt_flow_id ; Packet Flow Identifier +} + + + + + + +PRIM SN_DEACTIVATE_CNF 0x8002409E +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier +} + + + + + + +PRIM SN_DEACTIVATE_REQ 0x8001009E +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier + EXTERN @p_8010_152_ps_include - rel_ind@ rel_ind ; Local release indicator +} + + + + + + +PRIM SN_GET_PENDING_PDU_CNF 0x8003409E +{ + ul_pdus [0..SIZE_NSAPI] ; Array of DTI description lists and sequence numbers. +} + + + + + + +PRIM SN_GET_PENDING_PDU_REQ 0x8002009E +{ +} + + + + + + +PRIM SN_MODIFY_CNF 0x8004409E +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier +} + + + + + + +PRIM SN_MODIFY_REQ 0x8003009E +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier + EXTERN @p_8010_152_ps_include - sapi@ sapi ; LLC service access point identifier + EXTERN @p_8010_152_ps_include - radio_prio@ radio_prio ; Radio priority + EXTERN @p_8010_152_ps_include - qos_r97@ qos_r97 AS snsm_qos ; Reliability class and other qos + EXTERN @p_8010_152_ps_include - pkt_flow_id@ pkt_flow_id ; Packet Flow Identifier +} + + + + + + +PRIM SN_STATUS_IND 0x8005409E +{ + EXTERN @p_8010_137_nas_include - nsapi_set@ nsapi_set ; Set of network layer service access point identifier + EXTERN @p_8010_152_ps_include - sapi@ sapi ; LLC service access point identifier + EXTERN @p_8010_153_cause_include - ps_cause@ ps_cause ; Cause parameter +} + + + + + + +PRIM SN_SEQUENCE_REQ 0x8004009E +{ + receive_no_list [0..SIZE_NSAPI] ; Receive NDPU number list +} + + + + + + +PRIM SN_SEQUENCE_CNF 0x8006409E +{ + receive_no_list [0..SIZE_NSAPI] ; Receive NDPU number list +} + + + + + + +PRIM SN_COUNT_REQ 0x8005009E +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; network layer service access point identifier + EXTERN @p_8010_137_nas_include - reset@ reset ; shall counters be reset +} + + + + + + +PRIM SN_COUNT_CNF 0x8008409E +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; network layer service access point identifier + EXTERN @p_8010_137_nas_include - octets_uplink@ octets_uplink ; octets uplink + EXTERN @p_8010_137_nas_include - octets_downlink@ octets_downlink ; octets downlink + EXTERN @p_8010_137_nas_include - packets_uplink@ packets_uplink ; packets uplink + EXTERN @p_8010_137_nas_include - packets_downlink@ packets_downlink ; packets downlink +} + + + + + + +PRIM SN_DTI_REQ 0x8006009E +{ + EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; network layer service access point identifier + EXTERN @p_8010_137_nas_include - dti_conn@ dti_conn ; dti connect + EXTERN @p_8010_137_nas_include - dti_linkid@ dti_linkid ; dti linkid + dti_neighbor ; dti neighbor + EXTERN @p_8010_137_nas_include - dti_direction@ dti_direction ; dti direction +} + + + + + + +PRIM SN_DTI_CNF 0x8009409E +{ + EXTERN @p_8010_137_nas_include - dti_linkid@ dti_linkid ; dti linkid + EXTERN @p_8010_137_nas_include - dti_conn@ dti_conn ; dti connect +} + + + + + + + + +