FreeCalypso > hg > fc-magnetite
diff cdg-hybrid/sap/8010_136_SIMDRV_SAP.pdf @ 212:e7a67accfad9
cdg-hybrid cdginc headers created
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Fri, 14 Oct 2016 21:52:58 +0000 |
parents | |
children |
line wrap: on
line diff
--- /dev/null Thu Jan 01 00:00:00 1970 +0000 +++ b/cdg-hybrid/sap/8010_136_SIMDRV_SAP.pdf Fri Oct 14 21:52:58 2016 +0000 @@ -0,0 +1,265 @@ +;******************************************************************************** +;*** File : 8010_136_simdrv_sap.pdf +;*** Creation : Wed Mar 11 09:57:50 CST 2009 +;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 +;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 +;******************************************************************************** +;*** Document Type : Service Access Point Specification +;*** Document Name : 8010_136_simdrv_sap +;*** Document No. : 8010.136.03.009 +;*** Document Date : 2004-06-10 +;*** Document Status: BEING_PROCESSED +;*** Document Author: FDU +;******************************************************************************** + + + +PRAGMA SRC_FILE_TIME "Thu Nov 29 09:27:56 2007" +PRAGMA LAST_MODIFIED "2004-06-10" +PRAGMA ID_AND_VERSION "8010.136.03.009" +PRAGMA PREFIX SIMDRV ; Prefix for this document +PRAGMA ALLWAYS_ENUM_IN_VAL_FILE YES ; Adds enumerations in the .val file. +PRAGMA ENABLE_GROUP YES ; Enable h-file grouping +PRAGMA COMPATIBILITY_DEFINES NO ; Compatible to the old #defines + + + +CONST SIZE_ATR_INFO 0x21 ; The maximum length of the data returned from the ATR procedure + GROUP uicc +CONST MIN_RESULT 0x01 ; Minimum size of the response of any given command + GROUP uicc +CONST MAX_RESULT 0x100 ; Maximum size of the response of any given command + GROUP uicc +CONST MIN_DATA_SIZE 0x01 ; Minimum length of a data element + GROUP uicc +CONST MAX_DATA_SIZE 0xFF ; Maximum length of a data element + GROUP uicc +CONST MAX_READERS 0x02 ; Maximum number of card readers supported. + GROUP uicc + + + +VALTAB VAL_reset_return_val + GROUP uicc +VAL 0 SIM_INSERTED "A SIM is inserted and ATR/PPS was successful" +VAL 1 SIM_NOT_INSERTED "No SIM inserted (hardware detected)" +VAL 2 INVALID_CARD "Card is not responding or gives unintelligible answers, communications time out." +VAL 3 ME_FAILURE "Power management related problems, e.g. voltage selection" +VAL 4 IMPROPER_CALL_BACK "simdrv_register function called with pointer improperly set, e.g. NULL." +VAL 5 ME_READER_NOT_AVAILABLE "The reader requested is not available" + +VALTAB VAL_len + GROUP uicc +VAL 0x00 - 0x100 "Range of Length of Data" +VAL 0xFFFF LENGTH_UNKNOWN "Indicating that the length expected is unknown." + +VALTAB VAL_sw1_2 + GROUP uicc +VAL 0x0001 ERR_NOCARD "No SIM inserted (hardware detected)" +VAL 0x0002 ERR_NOT_RESET "A reset has not been performed on the driver with the requested Id." +VAL 0x0003 ERR_ME_FAIL "Unrecoverable ME failure (for instance interrupt fails to occur)" +VAL 0x0004 ERR_RETRY_FAIL "ME/SIM communication failed after certain retries, SIM reset required" +VAL 0x0005 ERR_PARAM_WRONG "A driver function is called with invalid parameters" + +VALTAB VAL_cla + GROUP uicc +VAL 0xA0 GSM_CLASS_BYTE "GSM Class byte according to [GSM 11.11 / 3GPP 51.011]" +VAL 0x80 UMTS_CLASS_BYTE "UMTS Class byte according to [ETSI 102 221 10.1.2]" +VAL 0x00 UICC_CLASS_BYTE "UICC Class byte according to [ISO 7816-4]" + +VALTAB VAL_ins + GROUP uicc +VAL 0xA4 INS_SELECT "Select Instruction" +VAL 0xF2 INS_STATUS "Status Instruction" +VAL 0xB0 INS_READ_BINARY "Read Binary Instruction" +VAL 0xD6 INS_UPDATE_BINARY "Update Binary Instruction" +VAL 0xB2 INS_READ_RECORD "Read Record Instruction" +VAL 0xDC INS_UPDATE_RECORD "Update Record Instruction" +VAL 0xA2 INS_SEEK "Seek Instruction" +VAL 0x32 INS_INCREASE "Increase Instruction" +VAL 0x20 INS_VERIFY_CHV "Verify Chv Instruction" +VAL 0x24 INS_CHANGE_CHV "Change Chv Instruction" +VAL 0x26 INS_DISABLE_CHV "Disable Chv Instruction" +VAL 0x28 INS_ENABLE_CHV "Ensable Chv Instruction" +VAL 0x2C INS_UNBLOCK_CHV "Unblock Chv Instruction" +VAL 0x04 INS_INVALIDATE "Invalidate Instruction" +VAL 0x44 INS_REHABILITATE "Rehabilitate Instruction" +VAL 0x88 INS_AUTHENTICATE "Run GSM Algorithm (2/2.5G) / Authenticate (3G) Instruction" +VAL 0x10 INS_TERMINAL_PROFILE "Terminal Profile Instruction" +VAL 0xC2 INS_ENVELOPE "Envelope Instruction" +VAL 0x12 INS_FETCH "Fetch Instruction" +VAL 0x14 INS_TERMINAL_RESPONSE "Terminal Response Instruction" +VAL 0xC0 INS_GET_RESPONSE "Get Response Instruction" + +VALTAB VAL_voltage_select + GROUP uicc +VAL 0 REQ_VOLTAGE_SEL "The SIM reader driver shall perform voltage selection" +VAL 1 OMIT_VOLTAGE_SEL "The SIM reader driver shall restart with the current voltage" + +VALTAB VAL_config_requested + GROUP uicc +VAL 0x00 OMIT_CONFIG_CHARACTERISTICS "PS Shall not retrieve Configuration Characteristics" +VAL 0x01 REQUEST_CONFIG_CHARACTERISTICS "PS Shall retrieve Configuration Characteristics" + +VALTAB VAL_reader_id + GROUP uicc +VAL 01 - MAX_READERS "Range of Id's of readers" + + + + +VAR insert_ptr "insert pointer" L + GROUP uicc + + +VAR remove_ptr "remove pointer" L + GROUP uicc + + +VAR atr_string "SIM Card Answer to reset string" B + GROUP uicc + + +VAR reset_return_val "Reset return value" B + GROUP uicc + +VAL @p_8010_136_simdrv_sap - VAL_reset_return_val@ + +VAR result "Result byte" B + GROUP uicc + + +VAR len "Maximum length of expected data" S + GROUP uicc + +VAL @p_8010_136_simdrv_sap - VAL_len@ + +VAR data "Data element" B + GROUP uicc + + +VAR sw1_2 "Status Words" S + GROUP uicc + +VAL @p_8010_136_simdrv_sap - VAL_sw1_2@ + +VAR cla "Class Byte" B + GROUP uicc + +VAL @p_8010_136_simdrv_sap - VAL_cla@ + +VAR ins "instruction code" B + GROUP uicc + +VAL @p_8010_136_simdrv_sap - VAL_ins@ + +VAR voltage_select "Perform Voltage Selection" B + GROUP uicc + +VAL @p_8010_136_simdrv_sap - VAL_voltage_select@ + +VAR p1 "Parameter 1 of the SIM APDU" B + GROUP uicc + + +VAR p2 "Parameter 2 of the SIM APDU" B + GROUP uicc + + +VAR config_requested "Configuration Characteristics requested" B + GROUP uicc + +VAL @p_8010_136_simdrv_sap - VAL_config_requested@ + +VAR reader_id "Reader Id" B + GROUP uicc + +VAL @p_8010_136_simdrv_sap - VAL_reader_id@ + +VAR uicc_characteristics "UICC Characteristics" B + GROUP uicc + + + + + +COMP atr_string_info "SIM Card Info" + GROUP uicc +{ + atr_string [2..SIZE_ATR_INFO] ; SIM Card Answer to reset string +} + + + +COMP result_info "Result Buffer" + GROUP uicc +{ + len ; Length of expected data + result DYN[MIN_RESULT..MAX_RESULT] ; Result byte +} + + + +COMP data_info "Data element info" + GROUP uicc +{ + data DYN[MIN_DATA_SIZE..MAX_DATA_SIZE] ; Data element +} + + + +COMP cmd_header "Transparent command header" + GROUP uicc +{ + cla ; Class Byte value + ins ; Instruction Code + p1 ; Parameter P1 + p2 ; Parameter P2 +} + + + +COMP config_characteristics "Configuration Characteristics" + GROUP uicc +{ + uicc_characteristics ; UICC Characteristics +} + + + + + + +; SIMDRV_DUMMY 0x80FF009A + + + +PRIM SIMDRV_DUMMY 0x80FF009A + GROUP uicc +{ + atr_string_info PTR ; SIM Card Info + reset_return_val ; Return Value + result_info PTR ; Result Buffer + len ; Length of expected data + data_info PTR ; Update Data Element + sw1_2 ; Status Words + cla ; Class Byte + ins ; Instruction Code + cmd_header ; Transparent command header + voltage_select ; Perform Voltage Selection + p1 ; SIM Command Parameters + p2 ; SIM Command Parameters + config_requested ; Configuration Characteristics requested + config_characteristics PTR ; Configuration Characteristics + reader_id ; Reader Id + uicc_characteristics ; UICC Characteristics +} + + + + + + + + +