view cdg-hybrid/sap/cst.pdf @ 624:012028896cfb

FFS dev.c, Leonardo target: Fujitsu MB84VF5F5F4J2 #if 0'ed out The FFS code we got from TI/Openmoko had a stanza for "Fujitsu MB84VF5F5F4J2 stacked device", using a fake device ID code that would need to be patched manually into cfgffs.c (suppressing and overriding autodetection) and using an FFS base address in the nCS2 bank, indicating that this FFS config was probably meant for the MCP version of Leonardo which allows for 16 MiB flash with a second bank on nCS2. We previously had this FFS config stanza conditionalized under CONFIG_TARGET_LEONARDO because the base address contained therein is invalid for other targets, but now that we actually have a Leonardo build target in FC Magnetite, I realize that the better approach is to #if 0 out this stanza altogether: it is already non-functional because it uses a fake device ID code, thus it is does not add support for more Leonardo board variants, instead it is just noise.
author Mychaela Falconia <falcon@freecalypso.org>
date Sun, 22 Dec 2019 21:24:29 +0000
parents e7a67accfad9
children
line wrap: on
line source

;********************************************************************************
;*** File           : cst.pdf
;*** Creation       : Wed Mar 11 09:57:45 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : cst
;*** Document No.   : 8415.060.99.003
;*** Document Date  : 1999-09-21
;*** Document Status: BEING_PROCESSED
;*** Document Author: Heiner
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:39:04 2007"
PRAGMA 	LAST_MODIFIED 	"1999-09-21"
PRAGMA 	ID_AND_VERSION 	"8415.060.99.003"









VAR 	adc_values 	"AD conversion values" 	S


VAR 	stop_address 	"contains stop address" 	L


VAR 	error_code 	"Error code" 	B


VAR 	index 	"Index" 	B








; CST_ADC_IND 	0x5600
; CST_VM_STOP_PLAY_IND 	0x5601
; CST_VM_STOP_RECORD_IND 	0x5602
; CST_SR_IND 	0x5603



PRIM 	CST_ADC_IND 	0x5600
{
 	adc_values 	[9] 	 ; AD conversion values
}






PRIM 	CST_VM_STOP_PLAY_IND 	0x5601
{
 	stop_address 	 ; stop address
}






PRIM 	CST_VM_STOP_RECORD_IND 	0x5602
{
 	stop_address 	 ; stop address
}






PRIM 	CST_SR_IND 	0x5603
{
 	error_code 	 ; Error code
 	index 	 ; Index
}