FFS dev.c, Leonardo target: Fujitsu MB84VF5F5F4J2 #if 0'ed out The FFS code we got from TI/Openmoko had a stanza for "Fujitsu MB84VF5F5F4J2 stacked device", using a fake device ID code that would need to be patched manually into cfgffs.c (suppressing and overriding autodetection) and using an FFS base address in the nCS2 bank, indicating that this FFS config was probably meant for the MCP version of Leonardo which allows for 16 MiB flash with a second bank on nCS2. We previously had this FFS config stanza conditionalized under CONFIG_TARGET_LEONARDO because the base address contained therein is invalid for other targets, but now that we actually have a Leonardo build target in FC Magnetite, I realize that the better approach is to #if 0 out this stanza altogether: it is already non-functional because it uses a fake device ID code, thus it is does not add support for more Leonardo board variants, instead it is just noise.
author Mychaela Falconia <falcon@freecalypso.org>
date Sun, 22 Dec 2019 21:24:29 +0000
parents e7a67accfad9
children
line wrap: on
line source

;********************************************************************************
;*** File           : tb.pdf
;*** Creation       : Wed Mar 11 09:58:52 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : tb
;*** Document No.   : 8441.112.01.002
;*** Document Date  : 2001-07-17
;*** Document Status: BEING_PROCESSED
;*** Document Author: SAB
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:54:48 2007"
PRAGMA 	LAST_MODIFIED 	"2001-07-17"
PRAGMA 	ID_AND_VERSION 	"8441.112.01.002"



CONST 	TB_BA_LIST_SIZE 	33 	; BA list size



VALTAB 	VAL_arfcn
VAL 	1 - 124 	"GSM 900 without extension band"
VAL 	1 - 174 	"GSM 900 with extension band"
VAL 	512 - 810 	"PCS 1900"
VAL 	512 - 885 	"DCS 1800"
VAL 	1 - 498 	"Dual band(GSM/DCS)"
VAL 	1 - 548 	"Dual band(EGSM/DCS)"
VAL 	0xFFFF 	TB_INVALID_ARFCN 	"Used to mark a channel number entry as invalid."




VAR 	num_meas 	"number" 	B


VAR 	rxlev 	"measurement value" 	S


VAR 	arfcn 	"channel number" 	S

VAL 	@p_tb - VAL_arfcn@ 	

VAR 	sc_rxlev 	"RXLEV value of the serving cell." 	B





COMP 	tb_meas_result 	 ""
{
 	arfcn 	 ; Channel Number
 	rxlev 	 ; ACC Level
 	num_meas 	 ; ACC nbr
}






; TB_MEAS_IND 	0x1800
; TB_RXLEV_SC_REQ 	0x5800



PRIM 	TB_MEAS_IND 	0x1800
{
 	tb_meas_result 	[TB_BA_LIST_SIZE] 	 ; Measurement result
}






PRIM 	TB_RXLEV_SC_REQ 	0x5800
{
 	sc_rxlev 	 ; RXLEV Serving Cell
}