tpudrv12.h & targets/gtm900.h: our current support is for MGC2GSMT version only
As it turns out, there exist two different Huawei-made hw platforms both
bearing the marketing name GTM900-B: one is MG01GSMT, the other is MGC2GSMT.
The two are NOT fw-compatible: aside from flash chip differences which
should be handled by autodetection, the two hw platforms are already known
to have different RFFEs with different control signals, and there may be
other differences not yet known. Our current gtm900 build target is for
MGC2GSMT only; we do not yet have a specimen of MG01GSMT on hand, hence
no support for that version will be possible until and unless someone
provides one.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Thu, 30 Jan 2020 18:19:01 +0000 |
parents | 56abf6cf8a0b |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : mnlc.pdf ;*** Creation : Fri Jun 08 13:58:00 CST 2007 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : mnlc ;*** Document No. : 8443.104.02.003 ;*** Document Date : 2002-10-25 ;*** Document Status: SUBMITTED ;*** Document Author: TML ;******************************************************************************** PRAGMA SRC_FILE_TIME "Mon Nov 24 15:50:46 2003" PRAGMA LAST_MODIFIED "2002-10-25" PRAGMA ID_AND_VERSION "8443.104.02.003" CONST L_MAX_CALLED_BCD_NO_LENGTH 10 ; Max Bcd number length (digits) CONST CURSOR_SMS_TEXT_140 140 ; Position SMS Message VALTAB VAL_data_valid VAL 0 DATA_VALID "" VAL 1 DATA_INVALID "" VAR reference "Reference" S VAR bcd "Bcd Number" B VAR data_valid "Cursor Data Valid" B VAL @p_mnlc - VAL_data_valid@ VAR number_length "Number of decimal digits in the Bcd number" B VAR sms_text "SMS text" B COMP called_party_bcd_num "called Party Bcd number" { number_length ; Number Length bcd [L_MAX_CALLED_BCD_NO_LENGTH] ; Bcd Number } ; MNLC_SMS_MEAS_REQ 0x80000044 ; MNLC_SMS_MEAS_CNF 0x80004044 PRIM MNLC_SMS_MEAS_REQ 0x80000044 { reference ; Reference SMS request called_party_bcd_num ; Called Bcd Number } PRIM MNLC_SMS_MEAS_CNF 0x80004044 { reference ; Reference SMS request data_valid ; Cursor Data Valid sms_text [CURSOR_SMS_TEXT_140] ; Cursor SMS }