view cdg211/prim/tb.pdf @ 639:026c98f757a6

tpudrv12.h & targets/gtm900.h: our current support is for MGC2GSMT version only As it turns out, there exist two different Huawei-made hw platforms both bearing the marketing name GTM900-B: one is MG01GSMT, the other is MGC2GSMT. The two are NOT fw-compatible: aside from flash chip differences which should be handled by autodetection, the two hw platforms are already known to have different RFFEs with different control signals, and there may be other differences not yet known. Our current gtm900 build target is for MGC2GSMT only; we do not yet have a specimen of MG01GSMT on hand, hence no support for that version will be possible until and unless someone provides one.
author Mychaela Falconia <falcon@freecalypso.org>
date Thu, 30 Jan 2020 18:19:01 +0000
parents 56abf6cf8a0b
children
line wrap: on
line source

;********************************************************************************
;*** File           : tb.pdf
;*** Creation       : Fri Jun 08 13:58:39 CST 2007
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : tb
;*** Document No.   : 8441.112.01.002
;*** Document Date  : 2001-07-17
;*** Document Status: BEING_PROCESSED
;*** Document Author: SAB
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Mon Nov 24 15:51:14 2003"
PRAGMA 	LAST_MODIFIED 	"2001-07-17"
PRAGMA 	ID_AND_VERSION 	"8441.112.01.002"



CONST 	TB_BA_LIST_SIZE 	33 	; BA list size



VALTAB 	VAL_arfcn
VAL 	1 - 124 	"GSM 900 without extension band"
VAL 	1 - 174 	"GSM 900 with extension band"
VAL 	512 - 810 	"PCS 1900"
VAL 	512 - 885 	"DCS 1800"
VAL 	1 - 498 	"Dual band(GSM/DCS)"
VAL 	1 - 548 	"Dual band(EGSM/DCS)"
VAL 	0xFFFF 	TB_INVALID_ARFCN 	"Used to mark a channel number entry as invalid."




VAR 	num_meas 	"number" 	B


VAR 	rxlev 	"measurement value" 	S


VAR 	arfcn 	"channel number" 	S

VAL 	@p_tb - VAL_arfcn@ 	

VAR 	sc_rxlev 	"RXLEV value of the serving cell." 	B





COMP 	tb_meas_result 	 ""
{
 	arfcn 	 ; Channel Number
 	rxlev 	 ; ACC Level
 	num_meas 	 ; ACC nbr
}






; TB_MEAS_IND 	0x1800
; TB_RXLEV_SC_REQ 	0x5800



PRIM 	TB_MEAS_IND 	0x1800
{
 	tb_meas_result 	[TB_BA_LIST_SIZE] 	 ; Measurement result
}






PRIM 	TB_RXLEV_SC_REQ 	0x5800
{
 	sc_rxlev 	 ; RXLEV Serving Cell
}