tpudrv12.h & targets/gtm900.h: our current support is for MGC2GSMT version only
As it turns out, there exist two different Huawei-made hw platforms both
bearing the marketing name GTM900-B: one is MG01GSMT, the other is MGC2GSMT.
The two are NOT fw-compatible: aside from flash chip differences which
should be handled by autodetection, the two hw platforms are already known
to have different RFFEs with different control signals, and there may be
other differences not yet known. Our current gtm900 build target is for
MGC2GSMT only; we do not yet have a specimen of MG01GSMT on hand, hence
no support for that version will be possible until and unless someone
provides one.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Thu, 30 Jan 2020 18:19:01 +0000 |
parents | 56abf6cf8a0b |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : tra.pdf ;*** Creation : Fri Jun 08 13:58:41 CST 2007 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : tra ;*** Document No. : 8411.106.98.101 ;*** Document Date : 2002-06-10 ;*** Document Status: BEING_PROCESSED ;*** Document Author: TVO ;******************************************************************************** PRAGMA SRC_FILE_TIME "Mon Nov 24 15:49:20 2003" PRAGMA LAST_MODIFIED "2002-06-10" PRAGMA ID_AND_VERSION "8411.106.98.101" VALTAB VAL_entity_name VAL 6 TRA_ENTITY_NAME_LEN "Max name length" VALTAB VAL_ack_flg VAL 0 TRA_ACK "acknowledged" VAL 1 TRA_NAK "not acknowledged" VALTAB VAL_dti_direction VAL 0 TRA_DTI_NORMAL "DTI used normally" VAL 1 TRA_DTI_INVERTED "DTI is inverted" VALTAB VAL_dti_conn VAL 0 TRA_CONNECT_DTI "Connect DTI to TRA" VAL 1 TRA_DISCONNECT_DTI "Connect DTI to upper layer" VAR entity_name "name of an neighbour entity" B VAL @p_tra - VAL_entity_name@ VAR ack_flg "acknowledge flag" B VAL @p_tra - VAL_ack_flg@ VAR link_id "link identifier" L VAR dti_direction "DTI direction" B VAL @p_tra - VAL_dti_direction@ VAR dti_conn "DTI connect" B VAL @p_tra - VAL_dti_conn@ ; TRA_ACTIVATE_REQ 0x80000019 ; TRA_ACTIVATE_CNF 0x80004019 ; TRA_DEACTIVATE_REQ 0x80010019 ; TRA_DEACTIVATE_CNF 0x80014019 ; TRA_DTI_REQ 0x80020019 ; TRA_DTI_CNF 0x80024019 ; TRA_DTI_IND 0x80034019 PRIM TRA_ACTIVATE_REQ 0x80000019 { } PRIM TRA_ACTIVATE_CNF 0x80004019 { ack_flg ; acknowledge flag } PRIM TRA_DEACTIVATE_REQ 0x80010019 { } PRIM TRA_DEACTIVATE_CNF 0x80014019 { } PRIM TRA_DTI_REQ 0x80020019 { dti_conn ; DTI connect link_id ; Link identifier of DTI entity_name [TRA_ENTITY_NAME_LEN] ; Communication entity name dti_direction ; DTI direction } PRIM TRA_DTI_CNF 0x80024019 { dti_conn ; DTI connect link_id ; Link identifier } PRIM TRA_DTI_IND 0x80034019 { link_id ; link identifier }