FreeCalypso > hg > fc-magnetite
view cdg-hybrid/sap/8010_135_sn_sap.pdf @ 258:13bcc2ed7e44
configure.sh & targets/*.conf: emit FLASH_BASE_ADDR & FLASH_SECTOR_SIZE
into the generated Makefile
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Fri, 04 Aug 2017 07:14:16 +0000 |
parents | e7a67accfad9 |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : 8010_135_sn_sap.pdf ;*** Creation : Wed Mar 11 09:57:49 CST 2009 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : 8010_135_sn_sap ;*** Document No. : 8010.135.04.012 ;*** Document Date : 2004-06-08 ;*** Document Status: APPROVED ;*** Document Author: rpk ;******************************************************************************** PRAGMA SRC_FILE_TIME "Thu Nov 29 09:27:14 2007" PRAGMA LAST_MODIFIED "2004-06-08" PRAGMA ID_AND_VERSION "8010.135.04.012" PRAGMA PREFIX SN ; Prefix for this document PRAGMA ALLWAYS_ENUM_IN_VAL_FILE YES ; Enumeration values in value file PRAGMA ENABLE_GROUP NO ; Enable h-file grouping PRAGMA COMPATIBILITY_DEFINES NO ; Compatible to the old #defines CONST MAX_UL_PDU 255 ; Max number of unconfirmed PDUs transferred between RATs (in SN_GET_PENDING_PDU_CNF). EXTERN CONST @p_8010_137_nas_include - SIZE_NSAPI@ SIZE_NSAPI ; Maximum NSAPI array index for SN_GET_PENDING_PDU_CNF VALTAB VAL_establish VAL 0 ACTIVE_ESTABLISHMENT "SNDCP shall send LL_ESTABLISH_REQ" VAL 1 PASSIVE_ESTABLISHMENT "SNDCP shall wait for LL_ESTABLISH_IND" VAR list_len "Octet count of data in all descriptors" S VAR first "Pointer to first descriptor in list" L VAR dl_sequence_number "Sequence number of last unacknowledged downlink PDU (used by the network)" B VAR establish "" B VAL @p_8010_135_sn_sap - VAL_establish@ VAR receive_no "Receive NPDU number" B VAR dti_neighbor "DTI neighbor entity name." L COMP desc_list2 "DTI parameters" { list_len ; Octet count of data in all descriptors first ; Pointer to first descriptor in list } COMP ul_pdus "Sequence number and descriptor list handles pr. NSAPI" { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network Service Access Point Identifier dl_sequence_number ; Sequence number of last unacknowledged downlink PDU (used by the network) desc_list2 PTR [0 .. MAX_UL_PDU] ; List of unconfirmed uplink PDUs } COMP receive_no_list "Ssequence numbers and MEM handles pr. NSAPI" { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer Service Access Point Identifier receive_no ; Receive NPDU number } ; SN_ACTIVATE_CNF 0x8000409E ; SN_ACTIVATE_REQ 0x8000009E ; SN_DEACTIVATE_CNF 0x8002409E ; SN_DEACTIVATE_REQ 0x8001009E ; SN_GET_PENDING_PDU_CNF 0x8003409E ; SN_GET_PENDING_PDU_REQ 0x8002009E ; SN_MODIFY_CNF 0x8004409E ; SN_MODIFY_REQ 0x8003009E ; SN_STATUS_IND 0x8005409E ; SN_SEQUENCE_REQ 0x8004009E ; SN_SEQUENCE_CNF 0x8006409E ; SN_COUNT_REQ 0x8005009E ; SN_COUNT_CNF 0x8008409E ; SN_DTI_REQ 0x8006009E ; SN_DTI_CNF 0x8009409E PRIM SN_ACTIVATE_CNF 0x8000409E { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier EXTERN @p_8010_137_nas_include - comp_params@ comp_params ; Compression parameters } PRIM SN_ACTIVATE_REQ 0x8000009E { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier EXTERN @p_8010_152_ps_include - sapi@ sapi ; LLC service access point identifier EXTERN @p_8010_152_ps_include - radio_prio@ radio_prio ; Radio priority EXTERN @p_8010_152_ps_include - qos_r97@ qos_r97 AS snsm_qos ; Peak throughput and other qos establish ; Establish request EXTERN @p_8010_137_nas_include - comp_params@ comp_params ; Compression parameters EXTERN @p_8010_152_ps_include - pkt_flow_id@ pkt_flow_id ; Packet Flow Identifier } PRIM SN_DEACTIVATE_CNF 0x8002409E { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier } PRIM SN_DEACTIVATE_REQ 0x8001009E { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier EXTERN @p_8010_152_ps_include - rel_ind@ rel_ind ; Local release indicator } PRIM SN_GET_PENDING_PDU_CNF 0x8003409E { ul_pdus [0..SIZE_NSAPI] ; Array of DTI description lists and sequence numbers. } PRIM SN_GET_PENDING_PDU_REQ 0x8002009E { } PRIM SN_MODIFY_CNF 0x8004409E { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier } PRIM SN_MODIFY_REQ 0x8003009E { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; Network layer service access point identifier EXTERN @p_8010_152_ps_include - sapi@ sapi ; LLC service access point identifier EXTERN @p_8010_152_ps_include - radio_prio@ radio_prio ; Radio priority EXTERN @p_8010_152_ps_include - qos_r97@ qos_r97 AS snsm_qos ; Reliability class and other qos EXTERN @p_8010_152_ps_include - pkt_flow_id@ pkt_flow_id ; Packet Flow Identifier } PRIM SN_STATUS_IND 0x8005409E { EXTERN @p_8010_137_nas_include - nsapi_set@ nsapi_set ; Set of network layer service access point identifier EXTERN @p_8010_152_ps_include - sapi@ sapi ; LLC service access point identifier EXTERN @p_8010_153_cause_include - ps_cause@ ps_cause ; Cause parameter } PRIM SN_SEQUENCE_REQ 0x8004009E { receive_no_list [0..SIZE_NSAPI] ; Receive NDPU number list } PRIM SN_SEQUENCE_CNF 0x8006409E { receive_no_list [0..SIZE_NSAPI] ; Receive NDPU number list } PRIM SN_COUNT_REQ 0x8005009E { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; network layer service access point identifier EXTERN @p_8010_137_nas_include - reset@ reset ; shall counters be reset } PRIM SN_COUNT_CNF 0x8008409E { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; network layer service access point identifier EXTERN @p_8010_137_nas_include - octets_uplink@ octets_uplink ; octets uplink EXTERN @p_8010_137_nas_include - octets_downlink@ octets_downlink ; octets downlink EXTERN @p_8010_137_nas_include - packets_uplink@ packets_uplink ; packets uplink EXTERN @p_8010_137_nas_include - packets_downlink@ packets_downlink ; packets downlink } PRIM SN_DTI_REQ 0x8006009E { EXTERN @p_8010_137_nas_include - nsapi@ nsapi ; network layer service access point identifier EXTERN @p_8010_137_nas_include - dti_conn@ dti_conn ; dti connect EXTERN @p_8010_137_nas_include - dti_linkid@ dti_linkid ; dti linkid dti_neighbor ; dti neighbor EXTERN @p_8010_137_nas_include - dti_direction@ dti_direction ; dti direction } PRIM SN_DTI_CNF 0x8009409E { EXTERN @p_8010_137_nas_include - dti_linkid@ dti_linkid ; dti linkid EXTERN @p_8010_137_nas_include - dti_conn@ dti_conn ; dti connect }