FreeCalypso > hg > fc-magnetite
view cdg3/msg/rr_short_pd.mdf @ 258:13bcc2ed7e44
configure.sh & targets/*.conf: emit FLASH_BASE_ADDR & FLASH_SECTOR_SIZE
into the generated Makefile
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Fri, 04 Aug 2017 07:14:16 +0000 |
parents | c15047b3d00d |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : rr_short_pd.mdf ;*** Creation : Thu Jun 19 15:32:12 CST 2008 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Air Interface Message Specification ;*** Document Name : rr_short_pd ;*** Document No. : 8010.602.03.001 ;*** Document Date : 2003-11-06 ;*** Document Status: BEING_PROCESSED ;*** Document Author: LG ;******************************************************************************** PRAGMA SRC_FILE_TIME "Wed Nov 28 10:21:00 2007" PRAGMA LAST_MODIFIED "2003-11-06" PRAGMA ID_AND_VERSION "8010.602.03.001" PRAGMA CCDNAME RR_SHORT ; CCD name tag PRAGMA ALLWAYS_ENUM_IN_VAL_FILE NO ; Adds enumerations in the .val file. CONST L3MAX_ACK 251 ; GSM 4.06, section 5.8.5 CONST L3MAX 251 ; CONST MAX_NNC 96 ; Maximum number of cells in Neighbour cell list for Enhanced Measurements CONST MAX_BSICI 8 ; Maximum invalid BSIC information IE's (21*8-14) / (17+1) = 8 CONST MAX_2GEXT 132 ; Maximum length of MI 2G Extension (21*8-36) = 132 VALTAB VAL_bsic_seen VAL 0 NO_INV_BSIC_SEEN "No cell with invalid BSIC and allowed NCC part of BSIC is seen." VAL 1 INV_BSIC_SEEN "One cell or more with invalid BSIC and allowed NCC part of BSIC is seen." VALTAB VAL_cv_bep VAL 0 CV_BEP_0 "2.00 > std(BEP)/mean(BEP) > 1.75" VAL 1 CV_BEP_1 "1.75 > std(BEP)/mean(BEP) > 1.50" VAL 2 CV_BEP_2 "1.50 > std(BEP)/mean(BEP) > 1.25" VAL 3 CV_BEP_3 "1.25 > std(BEP)/mean(BEP) > 1.00" VAL 4 CV_BEP_4 "1.00 > std(BEP)/mean(BEP) > 0.75" VAL 5 CV_BEP_5 "0.75 > std(BEP)/mean(BEP) > 0.50" VAL 6 CV_BEP_6 "0.50 > std(BEP)/mean(BEP) > 0.25" VAL 7 CV_BEP_7 "0.25 > std(BEP)/mean(BEP) > 0.00" VALTAB VAL_dtx_used VAL 0 DTX_USED_NO "DTX was not used" VAL 1 DTX_USED_YES "DTX was used" VALTAB VAL_inv_bsic_rep VAL 0 NO_REPORT "Indicates that GSM cells with invalid BSIC and allowed NCC part should not be reported" VAL 1 YES_REPORT "Indicates that GSM cells with invalid BSIC and allowed NCC part should be reported" VALTAB VAL_pow_ctrl VAL 0 POW_CTRL_NO "PWRC is not set" VAL 1 POW_CTRL_YES "PWRC is set" VALTAB VAL_rep_rate VAL 0 NORMAL_RATE "SACCH rate reporting." VAL 1 REDUCED_RATE "Reduced reporting rate allowed." VALTAB VAL_report_type VAL 0 RT_EMR "MS shall use the Enhanced Measurement Report message, if at least one BSIC is allocated to each BA frequency, otherwise the Measurement Report message." VAL 1 RT_MR "The MS shall use the Measurement Report message for reporting." VALTAB VAL_scale VAL 0 SCALE_ZERO_DB "0 dB offset is used for the reported RXLEV values" VAL 1 SCALE_TEN_DB "+10 dB offset is used for the reported RXLEV values" VALTAB VAL_scale_ord VAL 0 SC_ORD_ZERO_DB "0 dB offset, which shall be used for the reported RXLEV values" VAL 1 SC_ORD_TEN_DB "+10 dB offset, which shall be used for the reported RXLEV values" VAL 2 SC_ORD_AUTOMATIC "automatic offset, which shall be used for the reported RXLEV values" VALTAB VAL_sl2h VAL DEF "reserved" VAL 0 SL2H_0 "Short Layer 2 header: UI command frame" VAR ba_start_bsic "BA Index Start BSIC" 5 VAR ba_ind "BA Sequence Number indication" 1 VAR ba_ind_3g "3G BA Sequence Number indication" 1 VAR bsic "BSIC" 6 VAR bsic_seen "BSIC Seen" 1 VAL @m_rr_short_pd - VAL_bsic_seen@ VAR cv_bep "Coefficient of Variation of BEP" 3 VAL @m_rr_short_pd - VAL_cv_bep@ VAR dtx_used "DTX USED" 1 VAL @m_rr_short_pd - VAL_dtx_used@ VAR extens "Extension" 1 VAR e_len "Extension Length" 8 VAR inv_bsic_rep "Invalid BSIC reporting" 1 VAL @m_rr_short_pd - VAL_inv_bsic_rep@ VAR mean_bep "Mean BEP" 5 VAR mp_cm "Measurement parameters change mark" 1 VAR msg_type "Message Type" 6 VAR mi_idx "MI Index" 4 VAR mi_c "MI Counter" 4 VAR mr "Multiband Reporting" 2 VAR nr_rcvd_bl "Number Of Received Blocks" 5 VAR pow_ctrl "Power Control Indicator" 1 VAL @m_rr_short_pd - VAL_pow_ctrl@ VAR rep_rate "Reporting Rate" 1 VAL @m_rr_short_pd - VAL_rep_rate@ VAR report_type "Report Type" 1 VAL @m_rr_short_pd - VAL_report_type@ VAR rxlev "RX Level" 6 VAR rep_q "Reporting Quantity" 6 VAR rxqual_full "RX Quality Full Serving Cell" 3 VAR scale "Scale" 1 VAL @m_rr_short_pd - VAL_scale@ VAR scale_ord "Scale ord" 2 VAL @m_rr_short_pd - VAL_scale_ord@ VAR serv_band_rep "Serving band reporting" 2 VAR sl2h "Short Layer 2 Header" 2 VAL @m_rr_short_pd - VAL_sl2h@ COMP emp "EM MEASUREMENT Parameters Description" { CSN1_S1 mr ; Multiband Reporting CSN1_S1 serv_band_rep ; Serving band reporting scale_ord ; Scale ord CSN1_S1 EXTERN @m_rr_com - report_900@ report_900 ; Reporting 900 CSN1_S1 EXTERN @m_rr_com - report_1800@ report_1800 ; Reporting 1800 CSN1_S1 EXTERN @m_rr_com - report_400@ report_400 ; Reporting 400 CSN1_S1 EXTERN @m_rr_com - report_1900@ report_1900 ; Reporting 1900 CSN1_S1 EXTERN @m_rr_com - report_850@ report_850 ; Reporting 850 } COMP i_bsic_i "Invalid BSIC Information" { ba_start_bsic ; BA List Index bsic ; BSIC rxlev ; GSM Reporting Quantity } COMP mi_ext "MI 2G Extension" { e_len ; Extension Length extens [e_len..MAX_2GEXT] ; Extension } COMP scdata "Serving Cell Data" { dtx_used ; DTX Used rxlev ; RX Level rxqual_full ; RX Quality Full mean_bep ; Mean BEP cv_bep ; Coefficient of Variation of BEP nr_rcvd_bl ; Number Of Received Blocks } COMP rep_q_arr "Structured Element" { CSN1_S1 rep_q ; reported quantity, present only if reported } COMP em_rep "EM Bitmap Type Reporting" { rep_q_arr [0..MAX_NNC] ; Reporting Quantities } MSG u_emr uplink 0b000100 ; Enhanced Measurement Report { GSM3_V msg_type ; Message Type GSM3_V sl2h ; Short Layer 2 Header GSM3_V ba_ind ; BA Sequence Number indication GSM3_V ba_ind_3g ; 3G BA Sequence Number indication GSM3_V bsic_seen ; BSIC Seen GSM3_V scale ; Scale CSN1_S1 scdata ; Serving Cell Data CSN1_S1 i_bsic_i [0..MAX_BSICI] ; Invalid BSIC Information CSN1_S1 em_rep ; EM Bitmap Type Reporting S_PADDING .00101011 (21) ; Spare Padding } MSG d_meas_inf downlink 0b000101 ; Measurement Information { GSM3_V msg_type ; Message Type GSM3_V sl2h ; Short Layer 2 Header GSM3_V ba_ind ; BA Sequence Number indication GSM3_V ba_ind_3g ; 3G BA Sequence Number indication GSM3_V mp_cm ; Measurement parameters change mark GSM3_V mi_idx ; MI Index GSM3_V mi_c ; MI Counter GSM3_V pow_ctrl ; Power Control Indicator GSM3_V report_type ; Report Type GSM3_V rep_rate ; Reporting Rate GSM3_V inv_bsic_rep ; Invalid BSIC Reporting CSN1_S1 EXTERN @m_rr_com - rtdd@ rtdd ; GPRS Real Time Difference Description CSN1_S1 EXTERN @m_rr_com - gprs_bsic@ gprs_bsic ; GPRS BSIC Description CSN1_S1 EXTERN @m_rr_com - gprs_rep_prio@ gprs_rep_prio ; Report Priority CSN1_S1 emp ; EM Measurement Parameters Description CSN1_S1 mi_ext ; MI 2G Extension S_PADDING .00101011 (21) ; Spare Padding }