view src/cs/drivers/drv_app/abb/abb_inth.h @ 640:16eb1b9640dc

target gtm900 renamed to gtm900mgc2 This change reflects the fact that the build target in question supports MGC2GSMT hardware only, and will NOT work on other hw that confusing bears the same end user name of GTM900, neither the LoCosto-based GTM900-C nor the Calypso-based MG01GSMT that has a different and incompatible RFFE. If we ever get our hands on a piece of MG01GSMT hw and add support for it, that other target will be named gtm900mg01.
author Mychaela Falconia <falcon@freecalypso.org>
date Fri, 31 Jan 2020 00:46:07 +0000
parents 945cf7f506b2
children
line wrap: on
line source

/**********************************************************************************/
/*            TEXAS INSTRUMENTS INCORPORATED PROPRIETARY INFORMATION              */
/*                                                                                */
/*   Property of Texas Instruments -- For  Unrestricted  Internal  Use  Only      */
/*   Unauthorized reproduction and/or distribution is strictly prohibited.  This  */
/*   product  is  protected  under  copyright  law  and  trade  secret law as an  */
/*   unpublished work.  Created 1987, (C) Copyright 1997 Texas Instruments.  All  */
/*   rights reserved.                                                             */
/*                                                                                */
/*                                                                                */
/*   Filename          : abb_inth.h                                               */
/*                                                                                */
/*   Description       : Functions to manage the ABB device interrupt.            */
/*                       The Serial Port Interface is used to connect the TI  	  */
/*					          	 Analog BaseBand (ABB).				    			      	          */
/*						           It is assumed that the ABB is connected as the SPI       */																				  
/*                       device 0, and ABB interrupt is mapped as external IT.    */																				  
/*														                                      						  */
/*   Author            : Pascal PUEL                                              */
/*                                                                                */
/*   Version number   : 1.0                                                       */
/*                                                                                */
/*   Date and time    : Jan 2003                                                  */
/*                                                                                */
/*   Previous delta   : Creation                                                  */
/*                                                                                */
/**********************************************************************************/
/*                                                                                */
/*   17/12/03                                                                     */
/*   The original abb_inth.h has been splitted between the actual abb_inth.h      */
/*   located in drv_apps directory and abb_inth_core.h located in drv_core        */
/*   directory.                                                                   */
/*   abb_core_inth.h must be included in abb_inth.h.                              */
/*                                                                                */
/**********************************************************************************/

#ifndef __ABB_INTH_H__
#define __ABB_INTH_H__

  #include "main/sys_types.h"
  #include "abb/abb_core_inth.h" 

  #ifndef _WINDOWS

    #include "l1sw.cfg"
    #include "chipset.cfg"
  
    /****************************************************************/
    /* Power ON/OFF key definition.                                 */
    /****************************************************************/
    // If <ON/OFF> key is pressed more than 20 TDMAs, it's a Hook-ON
    #define SHORT_OFF_KEY_PRESSED  (20)
  
    // If <ON/OFF> key is pressed more than 160 TDMAs, it's a Hook-ON AND then Power-OFF
    #define OFF_LOOP_COUNT   (8)
    #define LONG_OFF_KEY_PRESSED   (OFF_LOOP_COUNT * SHORT_OFF_KEY_PRESSED)
  
  #endif   // _WINDOWS
  
  // PROTOTYPES
  void spi_abb_read_int_reg_callback(SYS_UWORD16 *read_value);

#endif  // __ABB_INTH_H__