targets/fcdev3b.h: bring back CONFIG_TARGET_FCDEV3B C preprocessor symbol CONFIG_TARGET_FCMODEM is no longer used anywhere in our code base, thus it is being fully retired. OTOH, CONFIG_TARGET_FCDEV3B is being brought back: with our earlier FC modem family idea now being withdrawn in light of the discovery of Tango modules, FCDEV3B goes back to being its own unique target.
author Mychaela Falconia <falcon@freecalypso.org>
date Thu, 24 Sep 2020 20:21:51 +0000
parents c15047b3d00d
children
line wrap: on
line source

;********************************************************************************
;*** File           : cst.pdf
;*** Creation       : Wed Mar 11 09:57:45 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : cst
;*** Document No.   : 8415.060.99.003
;*** Document Date  : 1999-09-21
;*** Document Status: BEING_PROCESSED
;*** Document Author: Heiner
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:39:04 2007"
PRAGMA 	LAST_MODIFIED 	"1999-09-21"
PRAGMA 	ID_AND_VERSION 	"8415.060.99.003"









VAR 	adc_values 	"AD conversion values" 	S


VAR 	stop_address 	"contains stop address" 	L


VAR 	error_code 	"Error code" 	B


VAR 	index 	"Index" 	B








; CST_ADC_IND 	0x5600
; CST_VM_STOP_PLAY_IND 	0x5601
; CST_VM_STOP_RECORD_IND 	0x5602
; CST_SR_IND 	0x5603



PRIM 	CST_ADC_IND 	0x5600
{
 	adc_values 	[9] 	 ; AD conversion values
}






PRIM 	CST_VM_STOP_PLAY_IND 	0x5601
{
 	stop_address 	 ; stop address
}






PRIM 	CST_VM_STOP_RECORD_IND 	0x5602
{
 	stop_address 	 ; stop address
}






PRIM 	CST_SR_IND 	0x5603
{
 	error_code 	 ; Error code
 	index 	 ; Index
}