view src/cs/drivers/drv_app/pwr/pwr_disch.c @ 665:2795a11973b8

UART PS entity: added trace of line state changes
author Mychaela Falconia <falcon@freecalypso.org>
date Wed, 27 May 2020 22:46:55 +0000
parents c93a236e0d50
children
line wrap: on
line source

/*******************************************************************************
 *
 * pwr_disch.c
 *
 * Purpose: This file contains functions for battery discharge management.
 *
 * (C) Texas Instruments 2001
 *
 ******************************************************************************/

#include "rv/rv_defined_swe.h"	   // for RVM_PWR_SWE

#ifdef RVM_PWR_SWE

#include "abb/abb.h"
#include "rvm/rvm_use_id_list.h"
#include "pwr/pwr_disch.h"
#include "power/power.h"
#include "spi/spi_task.h"
#include "pwr/pwr_cust.h"
#include "pwr/pwr_messages.h"
#include "spi/spi_env.h"
#include "pwr/pwr_env.h"

/* Define a pointer to the PWR Environment control block.  */
extern T_PWR_ENV_CTRL_BLK *pwr_env_ctrl_blk;




/*******************************************************************************
** Function         pwr_discharge_timer_process
**
** Description      
**
*******************************************************************************/
void pwr_discharge_timer_process(void)
{
   rvf_send_trace("TIMER3", 6, NULL_PARAM, RV_TRACE_LEVEL_DEBUG_LOW, PWR_USE_ID);
   if (SPI_GBL_INFO_PTR->is_gsm_on == TRUE)
   {
      pwr_handle_discharge(); /* battery discharge management */
   } 

}



/*******************************************************************************
** Function         pwr_handle_discharge
**
** Description      Compares the battery voltage with some thresholds and, if a 
**                  threshold is passed, sends event(s) to the upper layer.
**                  Re-start the timer with a value depending on the discharge 
**                  level.
**
*******************************************************************************/
void pwr_handle_discharge(void)
{
   UINT16 timer_value;
   UINT16 status;
   UINT16 bat_madc_voltage, bat_voltage;
   static T_PWR_PERCENT remain_capacity = 100;  /* since this variable is declared as static */
                                                /* it will keep its value from one function call to the other */
   T_PWR_PERCENT current_capacity;
  
   if (SPI_GBL_INFO_PTR->is_adc_on == FALSE) 
   {
      /* Start VBAT channel conversion by writing in the result register */
      ABB_Write_Register_on_page(PAGE0, VBATREG, 0x0000);
      rvf_delay(RVF_MS_TO_TICKS(5));
      bat_madc_voltage = ABB_Read_Register_on_page(PAGE0, VBATREG);
      rvf_send_trace("battery voltage (MADC code) ", 28, bat_madc_voltage, RV_TRACE_LEVEL_DEBUG_LOW, PWR_USE_ID);
   }
   else /* The L1 asks for ADC conversions */
   {
#ifndef _WINDOWS
      bat_madc_voltage = SPI_GBL_INFO_PTR->adc_result[0];
#else
      bat_madc_voltage = ABB_Read_Register_on_page(PAGE0, VBATREG);
#endif
   }

   /* Find the remaining capacity in the battery corresponding to this new voltage */
   bat_voltage = pwr_adc_to_mvolt(bat_madc_voltage);
   rvf_send_trace("battery voltage (mV) ", 21, bat_voltage, RV_TRACE_LEVEL_DEBUG_LOW, PWR_USE_ID);
   current_capacity = pwr_get_capacity_vs_voltage(bat_voltage);
   rvf_send_trace("current capacity (%) ", 21, current_capacity, RV_TRACE_LEVEL_DEBUG_LOW, PWR_USE_ID);

   status = ABB_Read_Status();

   /* Determine if a threshold has been passed */
   if (current_capacity != remain_capacity) 
   {
      /* a new threshold has been passed */
      remain_capacity = current_capacity;

      /* informs the upper layer */
      pwr_send_bat_discharge_event(remain_capacity);

      if (status & CHGPRES)   /* charger plugged */
      {
         if (remain_capacity == CHARGE_START_AGAIN_CAPACITY)
         {
            PWR_Charger_Plug();
         }
      }

      else  /* charger not plugged */
      {
         if(remain_capacity <= pwr_env_ctrl_blk->power_alert.remain_capa_threshold)
         {
            /* informs the upper layer that the battery is low */
            pwr_send_low_bat_event(remain_capacity);
            timer_value = SPI_TIMER3_INTERVAL_BIS; /* 10 s */
         }
         else  
         {
#ifndef _WINDOWS
            timer_value = SPI_TIMER3_INTERVAL; /* 1 minute */
#else
            timer_value = SPI_TIMER3_INTERVAL_BIS; /* 10 s */
#endif
         }

         /* Start timer with a value depending on the remaining capacity in the battery */
         rvf_start_timer (SPI_TIMER3,
                          RVF_MS_TO_TICKS (timer_value),
                          FALSE);
      }
   }

   else /* the capacity has not changed */
   {
#ifndef _WINDOWS
      timer_value = SPI_TIMER3_INTERVAL; /* 1 minute */
#else
      timer_value = SPI_TIMER3_INTERVAL_BIS; /* 10 s */
#endif

      /* Start timer with a value depending on the remaining capacity in the battery */
      rvf_start_timer (SPI_TIMER3,
                       RVF_MS_TO_TICKS (timer_value),
                       FALSE);

   }
}

#endif /* #ifdef RVM_PWR_SWE */