bmi3: fixed the mysterious "mute on first call" bug
When UI-enabled fw boots on a previously blank (no /mmi/* files) FFS
for the first time, the output_volume member of the persistent UI settings
structure was left uninitialized, corresponding to the earpiece volume
being set to mute, which is an invalid setting. Because of other quirks
in the far-from-finished UI code, this volume setting takes effect only
when the first call is answered, producing the odd behaviour seen at the
user level.
The current fix is to set the blank-FFS default for output_volume to
volume level 4, which is the same -6 dB Iota volume as the ACI default.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Thu, 14 May 2020 02:50:41 +0000 |
parents | e7a67accfad9 |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : mnlc.pdf ;*** Creation : Wed Mar 11 09:58:25 CST 2009 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : mnlc ;*** Document No. : 8443.104.02.003 ;*** Document Date : 2002-10-25 ;*** Document Status: SUBMITTED ;*** Document Author: TML ;******************************************************************************** PRAGMA SRC_FILE_TIME "Thu Nov 29 09:48:12 2007" PRAGMA LAST_MODIFIED "2002-10-25" PRAGMA ID_AND_VERSION "8443.104.02.003" CONST L_MAX_CALLED_BCD_NO_LENGTH 10 ; Max Bcd number length (digits) CONST CURSOR_SMS_TEXT_140 140 ; Position SMS Message VALTAB VAL_data_valid VAL 0 DATA_VALID "" VAL 1 DATA_INVALID "" VAR reference "Reference" S VAR bcd "Bcd Number" B VAR data_valid "Cursor Data Valid" B VAL @p_mnlc - VAL_data_valid@ VAR number_length "Number of decimal digits in the Bcd number" B VAR sms_text "SMS text" B COMP called_party_bcd_num "called Party Bcd number" { number_length ; Number Length bcd [L_MAX_CALLED_BCD_NO_LENGTH] ; Bcd Number } ; MNLC_SMS_MEAS_REQ 0x80000044 ; MNLC_SMS_MEAS_CNF 0x80004044 PRIM MNLC_SMS_MEAS_REQ 0x80000044 { reference ; Reference SMS request called_party_bcd_num ; Called Bcd Number } PRIM MNLC_SMS_MEAS_CNF 0x80004044 { reference ; Reference SMS request data_valid ; Cursor Data Valid sms_text [CURSOR_SMS_TEXT_140] ; Cursor SMS }