bmi3: fixed the mysterious "mute on first call" bug
When UI-enabled fw boots on a previously blank (no /mmi/* files) FFS
for the first time, the output_volume member of the persistent UI settings
structure was left uninitialized, corresponding to the earpiece volume
being set to mute, which is an invalid setting. Because of other quirks
in the far-from-finished UI code, this volume setting takes effect only
when the first call is answered, producing the odd behaviour seen at the
user level.
The current fix is to set the blank-FFS default for output_volume to
volume level 4, which is the same -6 dB Iota volume as the ACI default.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Thu, 14 May 2020 02:50:41 +0000 |
parents | 56abf6cf8a0b |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : tst.mdf ;*** Creation : Fri Jun 08 13:59:02 CST 2007 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Air Interface Message Specification ;*** Document Name : tst ;*** Document No. : 8441.603.99.005 ;*** Document Date : 2000-10-23 ;*** Document Status: BEING_PROCESSED ;*** Document Author: ANS ;******************************************************************************** PRAGMA SRC_FILE_TIME "Mon Nov 24 15:50:42 2003" PRAGMA LAST_MODIFIED "2000-10-23" PRAGMA ID_AND_VERSION "8441.603.99.005" CONST L3MAX 251 ; maximum size of a L3 buffer CONST MAX_N_PDU_NUMBER_LIST 11 ; maximum size of N-PDU number list VALTAB VAL_no_of_pdus VAL DEF "Number of PDUs to transmit" VAL 0 TEST_INFINITIVE_NO "ciphering not used" VALTAB VAL_dl_timeslot_offset VAL 0 TEST_TN0 "downlink timeslot offsett 0" VAL 1 TEST_TN1 "downlink timeslot offsett 1" VAL 2 TEST_TN2 "downlink timeslot offsett 2" VAL 3 TEST_TN3 "downlink timeslot offsett 3" VAL 4 TEST_TN4 "downlink timeslot offsett 4" VAL 5 TEST_TN5 "downlink timeslot offsett 5" VAL 6 TEST_TN6 "downlink timeslot offsett 6" VAL 7 TEST_TN7 "downlink timeslot offsett 7" VALTAB VAL_mode_flag_val VAL 0 TEST_RANDOM "pseudorandom data" VAL 1 TEST_LOOP "loop back" VAR msg_type "Message Type" 8 VAR no_of_pdus "Number of PDUs" 12 VAL @m_tst - VAL_no_of_pdus@ VAR dl_timeslot_offset "Downlink Timeslot Offset" 3 VAL @m_tst - VAL_dl_timeslot_offset@ VAR mode_flag_val "Mode Flag Value" 1 VAL @m_tst - VAL_mode_flag_val@ COMP pdu_description "PDU Description" { .000 ; spare no_of_pdus ; Number } COMP pdu_description_ie "PDU Description IE" { CSN1_S1 pdu_description ; PDU Description } COMP mode_flag "Mode Flag" { .0000 ; spare dl_timeslot_offset ; Downlink Timeslot Offset mode_flag_val ; Mode Flag Value } MSG gprs_test_mode_cmd downlink 36 ; gprs_test_mode_cmd { GSM3_V msg_type ; Message Type GSM3_V pdu_description_ie ; PDU description GSM3_V mode_flag ; Mode Flag }