bmi3: fixed the mysterious "mute on first call" bug
When UI-enabled fw boots on a previously blank (no /mmi/* files) FFS
for the first time, the output_volume member of the persistent UI settings
structure was left uninitialized, corresponding to the earpiece volume
being set to mute, which is an invalid setting. Because of other quirks
in the far-from-finished UI code, this volume setting takes effect only
when the first call is answered, producing the odd behaviour seen at the
user level.
The current fix is to set the blank-FFS default for output_volume to
volume level 4, which is the same -6 dB Iota volume as the ACI default.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Thu, 14 May 2020 02:50:41 +0000 |
parents | 56abf6cf8a0b |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : cst.pdf ;*** Creation : Fri Jun 08 13:57:06 CST 2007 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : cst ;*** Document No. : 8415.060.99.003 ;*** Document Date : 1999-09-21 ;*** Document Status: BEING_PROCESSED ;*** Document Author: Heiner ;******************************************************************************** PRAGMA SRC_FILE_TIME "Mon Nov 24 15:50:30 2003" PRAGMA LAST_MODIFIED "1999-09-21" PRAGMA ID_AND_VERSION "8415.060.99.003" VAR adc_values "AD conversion values" S VAR stop_address "contains stop address" L VAR error_code "Error code" B VAR index "Index" B ; CST_ADC_IND 0x5600 ; CST_VM_STOP_PLAY_IND 0x5601 ; CST_VM_STOP_RECORD_IND 0x5602 ; CST_SR_IND 0x5603 PRIM CST_ADC_IND 0x5600 { adc_values [9] ; AD conversion values } PRIM CST_VM_STOP_PLAY_IND 0x5601 { stop_address ; stop address } PRIM CST_VM_STOP_RECORD_IND 0x5602 { stop_address ; stop address } PRIM CST_SR_IND 0x5603 { error_code ; Error code index ; Index }