view cdg3/sap/ph.pdf @ 629:3231dd9b38c1

armio.c: make GPIOs 8 & 13 outputs driving 1 on all "classic" targets Calypso GPIOs 8 & 13 are pinmuxed with MCUEN1 & MCUEN2, respectively, and on powerup these pins are MCUEN, i.e., outputs driving 1. TI's code for C-Sample and earlier turns them into GPIOs configured as outputs also driving 1 - so far, so good - but TI's code for BOARD 41 (which covers D-Sample, Leonardo and all real world Calypso devices derived from the latter) switches them from MCUEN to GPIOs, but then leaves them as inputs. Given that the hardware powerup state of these two pins is outputs driving 1, every Calypso board design MUST be compatible with such driving; typically these GPIO signals will be either unused and unconnected or connected as outputs driving some peripheral. Turning these pins into GPIO inputs will result in floating inputs on every reasonably-wired board, thus I am convinced that this configuration is nothing but a bug on the part of whoever wrote this code at TI. This floating input bug had already been fixed earlier for GTA modem and FCDEV3B targets; the present change makes the fix unconditional for all "classic" targets. The newly affected targets are D-Sample, Leonardo, Tango and GTM900.
author Mychaela Falconia <falcon@freecalypso.org>
date Thu, 02 Jan 2020 05:38:26 +0000
parents c15047b3d00d
children
line wrap: on
line source

;********************************************************************************
;*** File           : ph.pdf
;*** Creation       : Wed Mar 11 09:58:34 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : ph
;*** Document No.   : 6147.112.01.100
;*** Document Date  : 2001-10-26
;*** Document Status: APPROVED
;*** Document Author: SBK
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:50:28 2007"
PRAGMA 	LAST_MODIFIED 	"2001-10-26"
PRAGMA 	ID_AND_VERSION 	"6147.112.01.100"



CONST 	DUMMY_PH 	0 	; Dummy, not used, needed to satisfy tool chain which requires at least one constant definition in a SAP



VALTAB 	VAL_ch_type
VAL 	0 	CH_TYPE_SACCH 	"SACCH"
VAL 	1 	CH_TYPE_SDCCH 	"SDCCH"
VAL 	2 	CH_TYPE_FACCH 	"FACCH Full Rate"
VAL 	3 	 	"reserved"
VAL 	4 	 	"reserved"
VAL 	5 	 	"reserved"
VAL 	6 	 	"reserved"
VAL 	7 	CH_TYPE_FACCH_HR 	"FACCH Half Rate"




VAR 	l2_channel 	"Layer 2 channel-type" 	B

VAL 	@p_mphc - VAL_l2_channel@ 	

VAR 	l_buf 	"length of content in bit" 	S


VAR 	o_buf 	"offset of content in bit" 	S


VAR 	buf 	"buffer content; the actual size of buf is determined and allocated at run-time and not restricted to 1;" 	B


VAR 	dummy 	"dummy not used" 	B





COMP 	sdu 	 "message unit"
{
 	l_buf 	 ; length of content in bit
 	o_buf 	 ; offset of content in bit
 	buf 	[1] 	 ; buffer content; the actual size of buf is determined and allocated at run-time and not restricted to 1;
}






; PH_READY_TO_SEND 	0x4100
; PH_DATA_REQ 	0x0100
; PH_TRACE_IND 	0x4102



PRIM 	PH_READY_TO_SEND 	0x4100
{
 	l2_channel AS ch_type 	 ; channel type
}






PRIM 	PH_DATA_REQ 	0x0100
{
 	l2_channel AS ch_type 	 ; channel type
 	dummy 	 ; dummy not used; reserved
 	sdu 	 ; message unit
}






PRIM 	PH_TRACE_IND 	0x4102
{
 	dummy 	 ; dummy not used; not used
}