;*** File           : rr_short_pd.mdf
;*** Creation       : Thu Jun 19 15:32:12 CST 2008
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Air Interface Message Specification
;*** Document Name  : rr_short_pd
;*** Document No.   : 8010.602.03.001
;*** Document Date  : 2003-11-06
;*** Document Status: BEING_PROCESSED
;*** Document Author: LG
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Wed Nov 28 10:21:00 2007"
PRAGMA 	LAST_MODIFIED 	"2003-11-06"
PRAGMA 	ID_AND_VERSION 	"8010.602.03.001"
PRAGMA 	CCDNAME 	RR_SHORT 	; CCD name tag
PRAGMA 	ALLWAYS_ENUM_IN_VAL_FILE 	NO 	; Adds enumerations in the .val file.



CONST 	L3MAX_ACK 	251 	; GSM 4.06, section 5.8.5
CONST 	L3MAX 	251 	; 
CONST 	MAX_NNC 	96 	; Maximum number of cells in Neighbour cell list for Enhanced Measurements
CONST 	MAX_BSICI 	8 	; Maximum invalid BSIC information IE's (21*8-14) / (17+1) = 8
CONST 	MAX_2GEXT 	132 	; Maximum length of MI 2G Extension (21*8-36) = 132



VALTAB 	VAL_bsic_seen
VAL 	0 	NO_INV_BSIC_SEEN 	"No cell with invalid BSIC and allowed NCC part of BSIC is seen."
VAL 	1 	INV_BSIC_SEEN 	"One cell or more with invalid BSIC and allowed NCC part of BSIC is seen."

VALTAB 	VAL_cv_bep
VAL 	0 	CV_BEP_0 	"2.00 > std(BEP)/mean(BEP) > 1.75"
VAL 	1 	CV_BEP_1 	"1.75 > std(BEP)/mean(BEP) > 1.50"
VAL 	2 	CV_BEP_2 	"1.50 > std(BEP)/mean(BEP) > 1.25"
VAL 	3 	CV_BEP_3 	"1.25 > std(BEP)/mean(BEP) > 1.00"
VAL 	4 	CV_BEP_4 	"1.00 > std(BEP)/mean(BEP) > 0.75"
VAL 	5 	CV_BEP_5 	"0.75 > std(BEP)/mean(BEP) > 0.50"
VAL 	6 	CV_BEP_6 	"0.50 > std(BEP)/mean(BEP) > 0.25"
VAL 	7 	CV_BEP_7 	"0.25 > std(BEP)/mean(BEP) > 0.00"

VALTAB 	VAL_dtx_used
VAL 	0 	DTX_USED_NO 	"DTX was not used"
VAL 	1 	DTX_USED_YES 	"DTX was used"

VALTAB 	VAL_inv_bsic_rep
VAL 	0 	NO_REPORT 	"Indicates that GSM cells with invalid BSIC and allowed NCC part should not be reported"
VAL 	1 	YES_REPORT 	"Indicates that GSM cells with invalid BSIC and allowed NCC part should be reported"

VALTAB 	VAL_pow_ctrl
VAL 	0 	POW_CTRL_NO 	"PWRC is not set"
VAL 	1 	POW_CTRL_YES 	"PWRC is set"

VALTAB 	VAL_rep_rate
VAL 	0 	NORMAL_RATE 	"SACCH rate reporting."
VAL 	1 	REDUCED_RATE 	"Reduced reporting rate allowed."

VALTAB 	VAL_report_type
VAL 	0 	RT_EMR 	"MS shall use the Enhanced Measurement Report message, if at least one BSIC is allocated to each BA frequency, otherwise the Measurement Report message."
VAL 	1 	RT_MR 	"The MS shall use the Measurement Report message for reporting."

VALTAB 	VAL_scale
VAL 	0 	SCALE_ZERO_DB 	"0 dB offset is used for the reported RXLEV values"
VAL 	1 	SCALE_TEN_DB 	"+10 dB offset is used for the reported RXLEV values"

VALTAB 	VAL_scale_ord
VAL 	0 	SC_ORD_ZERO_DB 	"0 dB offset, which shall be used for the reported RXLEV values"
VAL 	1 	SC_ORD_TEN_DB 	"+10 dB offset, which shall be used for the reported RXLEV values"
VAL 	2 	SC_ORD_AUTOMATIC 	"automatic offset, which shall be used for the reported RXLEV values"

VALTAB 	VAL_sl2h
VAL 	DEF 	 	"reserved"
VAL 	0 	SL2H_0 	"Short Layer 2 header: UI command frame"




VAR 	ba_start_bsic 	"BA Index Start BSIC" 	
 	5


VAR 	ba_ind 	"BA Sequence Number indication" 	
 	1


VAR 	ba_ind_3g 	"3G BA Sequence Number indication" 	
 	1


VAR 	bsic 	"BSIC" 	
 	6


VAR 	bsic_seen 	"BSIC Seen" 	
 	1

VAL 	@m_rr_short_pd - VAL_bsic_seen@ 	

VAR 	cv_bep 	"Coefficient of Variation of BEP" 	
 	3

VAL 	@m_rr_short_pd - VAL_cv_bep@ 	

VAR 	dtx_used 	"DTX USED" 	
 	1

VAL 	@m_rr_short_pd - VAL_dtx_used@ 	

VAR 	extens 	"Extension" 	
 	1


VAR 	e_len 	"Extension Length" 	
 	8


VAR 	inv_bsic_rep 	"Invalid BSIC reporting" 	
 	1

VAL 	@m_rr_short_pd - VAL_inv_bsic_rep@ 	

VAR 	mean_bep 	"Mean BEP" 	
 	5


VAR 	mp_cm 	"Measurement parameters change mark" 	
 	1


VAR 	msg_type 	"Message Type" 	
 	6


VAR 	mi_idx 	"MI Index" 	
 	4


VAR 	mi_c 	"MI Counter" 	
 	4


VAR 	mr 	"Multiband Reporting" 	
 	2


VAR 	nr_rcvd_bl 	"Number Of Received Blocks" 	
 	5


VAR 	pow_ctrl 	"Power Control Indicator" 	
 	1

VAL 	@m_rr_short_pd - VAL_pow_ctrl@ 	

VAR 	rep_rate 	"Reporting Rate" 	
 	1

VAL 	@m_rr_short_pd - VAL_rep_rate@ 	

VAR 	report_type 	"Report Type" 	
 	1

VAL 	@m_rr_short_pd - VAL_report_type@ 	

VAR 	rxlev 	"RX Level" 	
 	6


VAR 	rep_q 	"Reporting Quantity" 	
 	6


VAR 	rxqual_full 	"RX Quality Full Serving Cell" 	
 	3


VAR 	scale 	"Scale" 	
 	1

VAL 	@m_rr_short_pd - VAL_scale@ 	

VAR 	scale_ord 	"Scale ord" 	
 	2

VAL 	@m_rr_short_pd - VAL_scale_ord@ 	

VAR 	serv_band_rep 	"Serving band reporting" 	
 	2


VAR 	sl2h 	"Short Layer 2 Header" 	
 	2

VAL 	@m_rr_short_pd - VAL_sl2h@ 	




COMP 	emp 	"EM MEASUREMENT Parameters Description"
{
 	CSN1_S1  	mr 	 ; Multiband Reporting
 	CSN1_S1  	serv_band_rep 	 ; Serving band reporting
 	 	scale_ord 	 ; Scale ord
 	CSN1_S1 EXTERN @m_rr_com - report_900@ 	 	report_900 	 ; Reporting 900
 	CSN1_S1 EXTERN @m_rr_com - report_1800@ 	 	report_1800 	 ; Reporting 1800
 	CSN1_S1 EXTERN @m_rr_com - report_400@ 	 	report_400 	 ; Reporting 400
 	CSN1_S1 EXTERN @m_rr_com - report_1900@ 	 	report_1900 	 ; Reporting 1900
 	CSN1_S1 EXTERN @m_rr_com - report_850@ 	 	report_850 	 ; Reporting 850
}



COMP 	i_bsic_i 	"Invalid BSIC Information"
{
 	 	ba_start_bsic 	 ; BA List Index
 	 	bsic 	 ; BSIC
 	 	rxlev 	 ; GSM Reporting Quantity
}



COMP 	mi_ext 	"MI 2G Extension"
{
 	 	e_len 	 ; Extension Length
 	 	extens 	[e_len..MAX_2GEXT] 	 ; Extension
}



COMP 	scdata 	"Serving Cell Data"
{
 	 	dtx_used 	 ; DTX Used
 	 	rxlev 	 ; RX Level
 	 	rxqual_full 	 ; RX Quality Full
 	 	mean_bep 	 ; Mean BEP
 	 	cv_bep 	 ; Coefficient of Variation of BEP
 	 	nr_rcvd_bl 	 ; Number Of Received Blocks
}



COMP 	rep_q_arr 	"Structured Element"
{
 	CSN1_S1  	rep_q 	 ; reported quantity, present only if reported
}



COMP 	em_rep 	"EM Bitmap Type Reporting"
{
 	 	rep_q_arr 	[0..MAX_NNC] 	 ; Reporting Quantities
}






MSG 	u_emr 	uplink 	0b000100 ; Enhanced Measurement Report
{
 	GSM3_V  	msg_type 	 ; Message Type
 	GSM3_V  	sl2h 	 ; Short Layer 2 Header
 	GSM3_V  	ba_ind 	 ; BA Sequence Number indication
 	GSM3_V  	ba_ind_3g 	 ; 3G BA Sequence Number indication
 	GSM3_V  	bsic_seen 	 ; BSIC Seen
 	GSM3_V  	scale 	 ; Scale
 	CSN1_S1  	scdata 	 ; Serving Cell Data
 	CSN1_S1  	i_bsic_i 	[0..MAX_BSICI] 	 ; Invalid BSIC Information
 	CSN1_S1  	em_rep 	 ; EM Bitmap Type Reporting
 	S_PADDING .00101011 (21) ; Spare Padding
}



MSG 	d_meas_inf 	downlink 	0b000101 ; Measurement Information
{
 	GSM3_V  	msg_type 	 ; Message Type
 	GSM3_V  	sl2h 	 ; Short Layer 2 Header
 	GSM3_V  	ba_ind 	 ; BA Sequence Number indication
 	GSM3_V  	ba_ind_3g 	 ; 3G BA Sequence Number indication
 	GSM3_V  	mp_cm 	 ; Measurement parameters change mark
 	GSM3_V  	mi_idx 	 ; MI Index
 	GSM3_V  	mi_c 	 ; MI Counter
 	GSM3_V  	pow_ctrl 	 ; Power Control Indicator
 	GSM3_V  	report_type 	 ; Report Type
 	GSM3_V  	rep_rate 	 ; Reporting Rate
 	GSM3_V  	inv_bsic_rep 	 ; Invalid BSIC Reporting
 	CSN1_S1 EXTERN @m_rr_com - rtdd@ 	 	rtdd 	 ; GPRS Real Time Difference Description
 	CSN1_S1 EXTERN @m_rr_com - gprs_bsic@ 	 	gprs_bsic 	 ; GPRS BSIC Description
 	CSN1_S1 EXTERN @m_rr_com - gprs_rep_prio@ 	 	gprs_rep_prio 	 ; Report Priority
 	CSN1_S1  	emp 	 ; EM Measurement Parameters Description
 	CSN1_S1  	mi_ext 	 ; MI 2G Extension
 	S_PADDING .00101011 (21) ; Spare Padding
}