FreeCalypso > hg > fc-magnetite
view cdg3/sap/tb.pdf @ 628:38a65c3a96af
aci2 & aci3: AT@SPKR conditionalized on GPIO1_SPEAKER_CTRL
new preprocessor symbol
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Mon, 23 Dec 2019 07:30:59 +0000 |
parents | c15047b3d00d |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : tb.pdf ;*** Creation : Wed Mar 11 09:58:52 CST 2009 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : tb ;*** Document No. : 8441.112.01.002 ;*** Document Date : 2001-07-17 ;*** Document Status: BEING_PROCESSED ;*** Document Author: SAB ;******************************************************************************** PRAGMA SRC_FILE_TIME "Thu Nov 29 09:54:48 2007" PRAGMA LAST_MODIFIED "2001-07-17" PRAGMA ID_AND_VERSION "8441.112.01.002" CONST TB_BA_LIST_SIZE 33 ; BA list size VALTAB VAL_arfcn VAL 1 - 124 "GSM 900 without extension band" VAL 1 - 174 "GSM 900 with extension band" VAL 512 - 810 "PCS 1900" VAL 512 - 885 "DCS 1800" VAL 1 - 498 "Dual band(GSM/DCS)" VAL 1 - 548 "Dual band(EGSM/DCS)" VAL 0xFFFF TB_INVALID_ARFCN "Used to mark a channel number entry as invalid." VAR num_meas "number" B VAR rxlev "measurement value" S VAR arfcn "channel number" S VAL @p_tb - VAL_arfcn@ VAR sc_rxlev "RXLEV value of the serving cell." B COMP tb_meas_result "" { arfcn ; Channel Number rxlev ; ACC Level num_meas ; ACC nbr } ; TB_MEAS_IND 0x1800 ; TB_RXLEV_SC_REQ 0x5800 PRIM TB_MEAS_IND 0x1800 { tb_meas_result [TB_BA_LIST_SIZE] ; Measurement result } PRIM TB_RXLEV_SC_REQ 0x5800 { sc_rxlev ; RXLEV Serving Cell }