tpudrv12.h: FCDEV3B goes back to being itself
A while back we had the idea of a FreeCalypso modem family whereby our
current fcdev3b target would some day morph into fcmodem, with multiple
FC modem family products, potentially either triband or quadband, being
firmware-compatible with each other and with our original FCDEV3B. But
in light of the discovery of Tango modules that earlier idea is now being
withdrawn: instead the already existing Tango hw is being adopted into
our FreeCalypso family.
Tango cannot be firmware-compatible with triband OM/FCDEV3B targets
because the original quadband RFFE on Tango modules is wired in TI's
original Leonardo arrangement. Because this Leonardo/Tango way is now
becoming the official FreeCalypso way of driving quadband RFFEs thanks
to the adoption of Tango into our FC family, our earlier idea of
extending FIC's triband RFFE control signals with TSPACT5 no longer makes
much sense - we will probably never produce any new hardware with that
once-proposed arrangement. Therefore, that triband-or-quadband FCFAM
provision is being removed from the code base, and FCDEV3B goes back to
being treated the same way as CONFIG_TARGET_GTAMODEM for RFFE control
purposes.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Thu, 24 Sep 2020 21:03:08 +0000 |
parents | 219afcfc6250 |
children |
line wrap: on
line source
/* +----------------------------------------------------------------------------- | Project : GPRS (8441) | Modul : GRR +----------------------------------------------------------------------------- | Copyright 2002 Texas Instruments Berlin, AG | All rights reserved. | | This file is confidential and a trade secret of Texas | Instruments Berlin, AG | The receipt of or possession of this file does not convey | any rights to reproduce or disclose its contents or to | manufacture, use, or sell anything it may describe, in | whole, or in part, without the specific written consent of | Texas Instruments Berlin, AG. +----------------------------------------------------------------------------- | Purpose : This module implements primitive handler functions for service | PSI of entity GRR. +----------------------------------------------------------------------------- */ #ifndef GRR_PSIP_C #define GRR_PSIP_C #endif #define ENTITY_GRR /*==== INCLUDES =============================================================*/ #include "typedefs.h" /* to get Condat data types */ #include <string.h> #include "vsi.h" /* to get a lot of macros */ #include "macdef.h" #include "gprs.h" #include "gsm.h" /* to get a lot of macros */ #include "ccdapi.h" /* to get CCD API */ #include "cnf_grr.h" /* to get cnf-definitions */ #include "mon_grr.h" /* to get mon-definitions */ #include "prim.h" /* to get the definitions of used SAP and directions */ #include "message.h" #include "grr.h" /* to get the global entity definitions */ #include "grr_f.h" /* */ #include "grr_psip.h" /* header file of primitives*/ #include "grr_psif.h" /* header file of functions*/ #include "grr_meass.h" /* signals exchanged between PSI and MEAS*/ #include "grr_ctrls.h" /* header file of functions*/ /*==== CONST ================================================================*/ /*==== LOCAL VARS ===========================================================*/ /*==== PRIVATE FUNCTIONS ====================================================*/ /*==== PUBLIC FUNCTIONS =====================================================*/ /* +------------------------------------------------------------------------------ | Function : psi_t_60_sec +------------------------------------------------------------------------------ | Description : Handles the primitive T_60_SEC | | Parameters : void | +------------------------------------------------------------------------------ */ GLOBAL void psi_t_60_sec ( void ) { TRACE_FUNCTION( "t_60_sec" ); #ifndef _TARGET_ /* * No PSI1 or PSI13 or SI13 received within 60 sec * This will result in a cell reselection */ TRACE_EVENT( "No PSI1 or PSI13 or SI13 received within 60 sec" ); sig_psi_ctrl_psi1or_psi13_receiption_failure(); #else /* #ifndef _TARGET_ */ TRACE_EVENT( "Processing timeout of T_60_SEC disabled on target" ); #endif /* #ifndef _TARGET_ */ } /* psi_t_60_sec() */ /* +------------------------------------------------------------------------------ | Function : psi_t_30_sec +------------------------------------------------------------------------------ | Description : Handles the primitive T_30_SEC | | Parameters : void | +------------------------------------------------------------------------------ */ GLOBAL void psi_t_30_sec ( void) { TRACE_FUNCTION( "t_30_sec" ); /*#ifndef _TARGET_*/ /* * No PSI1 received within 30 sec */ switch( GET_STATE( PSI ) ) { case PSI_TRANSFER: if(grr_data->test_mode NEQ CGRLC_NO_TEST_MODE) { psi_start_30sec(); TRACE_EVENT( "T_30_SEC received during test mode" ); break; } /*lint -fallthrough*/ case PSI_IDLE: /* If the mobile station has not received the PSI1 message within the last 30 seconds, it shall attempt to receive the PSI1 message each time it is scheduled on PBCCH. Such attempts shall be made during both packet idle and packet transfer modes. */ switch(psc_db->acq_type) { case NONE: psc_db->acq_type = PERIODICAL_PSI1_READING; psi_receive_psi(READ_PSI1_IN_PSI1_REPEAT_PERIODS); break; default: /* * Access to the network not allowed or complete PSI * has not been read. Nothing to do. Acquisition is running */ TRACE_EVENT("PSI not complete/ access not allowed"); break; } break; case PSI_BCCH_TRANSFER: if(grr_data->test_mode NEQ CGRLC_NO_TEST_MODE) { psi_start_30sec(); TRACE_EVENT( "T_30_SEC received during test mode" ); break; } /*lint -fallthrough*/ case PSI_BCCH_IDLE: /* If the mobile station has received neither the SI13 nor the PSI13 message within the last 30 seconds, it shall attempt to receive the SI13 message each time it is scheduled on BCCH. Such attempts shall be made during both packet idle and packet transfer modes. */ switch(psc_db->acq_type) { case NONE: psc_db->acq_type = PERIODICAL_SI13_READING; sig_psi_ctrl_read_si( UPDATE_SI13 ); break; default: /* * Access to the network not allowed or complete SI * has not been read. Nothing to do. Acquisition is running */ TRACE_EVENT("SI not complete/ access not allowed"); break; } break; default: TRACE_ERROR( "T_30_SEC unexpected" ); break; } /*#endif*/ } /* psi_t_30_sec() */ /* +------------------------------------------------------------------------------ | Function : psi_t_10_sec +------------------------------------------------------------------------------ | Description : Handles the primitive T_10_SEC | | Parameters : void | +------------------------------------------------------------------------------ */ GLOBAL void psi_t_10_sec ( void ) { TRACE_FUNCTION( "t_10_sec" ); /* * partial or complete acq has not completed within 10 seconds */ /*#ifndef _TARGET_*/ if( grr_t_status( T3174 ) > 0 ) { TRACE_EVENT( "psi_t_10_sec expired when t3174 is running" ); return; } switch( GET_STATE( PSI ) ) { case PSI_IDLE: case PSI_TRANSFER: psi_stop_10sec(); /* If the mobile station has not received the required messages within 10 seconds * after the start of the acquisition procedure, an attempt to receive a missing message * shall be made each time the message is scheduled on the broadcast channel. * This case should not happen -except the network goes down. Reason: * in case of partial or complete acquisition we read all required (P)SI messages * each time the message is scheduled on the broadcast channel. Our reading process * continues until the 60 second expires or we receive the required messages. * If the 60 second timer expires we should perform a cell selection */ psi_update_data_to_request(INIT_NOT_NEEDED ); switch(psc_db->acq_type) { case COMPLETE: psi_complete_acq(COMPLETE); break; case PARTIAL: psi_partial_acq(); psc_db->send_psi_status = TRUE; /* this parameters has meaning if the network supports PSI STATUS */ break; default: TRACE_ERROR("Unknown acq_type in T_10_sec (PBCCH)"); break; } break; case PSI_BCCH_IDLE: case PSI_BCCH_TRANSFER: psi_stop_10sec(); /* Please see comment above */ switch(psc_db->acq_type) { case COMPLETE: sig_psi_ctrl_read_si(COMPLETE_SI); break; case PARTIAL: sig_psi_ctrl_read_si(psc_db->si_to_acquire); break; default: TRACE_ERROR("Unknown acq_type in T_10_sec (BCCH)"); break; } break; default: TRACE_ERROR( "T_10_SEC unexpected" ); break; } /*#endif*/ } /* psi_t_10_sec() */ /* +------------------------------------------------------------------------------ | Function : psi_complete_psi_read_failed +------------------------------------------------------------------------------ | Description : Handles the primitive PSI_COMPLETE_PSI_READ_FAILED | | Parameters : void | +------------------------------------------------------------------------------ */ GLOBAL void psi_complete_psi_read_failed ( void ) { TRACE_FUNCTION( "psi_complete_psi_read_failed" ); /* * reading of complete PSI within 10 sec failed * Stop PBCCH reading if running, * Inform CTRL, cell reselection should be performed */ TRACE_EVENT("reading of complete PSI within 10 sec failed"); if( grr_t_status( T3174 ) > 0 ) { TRACE_EVENT( "psi_complete_psi expired when t3174 is running" ); return; } SET_STATE( PSI, PSI_NULL ); if(psc_db->acq_type NEQ NONE) /* acquisition has been running, so we have to stop this acq.*/ { TRACE_EVENT("psi_stop_psi_reading"); psi_stop_psi_reading(NONE); } psi_stop_timer(); psi_reset_all(); /* * Perform CR */ sig_psi_ctrl_psi1or_psi13_receiption_failure(); } /* psi_complete_psi_read_failed() */