view cdg-hybrid/sap/mnlc.pdf @ 695:530f71d65c20

uartfax.c: pull from Tourmaline (GTM900 RI output) In addition to the primary intent of bringing in GTM900 RI output support, pulling uartfax.c wholesale from Tourmaline also changes the initial_time argument in the two NU_Create_Timer() calls from 0 to 1. This change is required for the new version of Nucleus used in Tourmaline and Selenite (and apparently also used by TI in LoCosto), and it is harmless (no effect) for the original TCS211 version of Nucleus used in Magnetite. The new philosophical model being adopted is that Tourmaline is our new development head firmware, whereas Magnetite will now be maintained similarly to how Linux maintainers treat stable kernels: changes will be backported from Tourmaline if they are deemed appropriate for stable modem firmware.
author Mychaela Falconia <falcon@freecalypso.org>
date Sat, 24 Oct 2020 17:33:10 +0000
parents e7a67accfad9
children
line wrap: on
line source

;********************************************************************************
;*** File           : mnlc.pdf
;*** Creation       : Wed Mar 11 09:58:25 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : mnlc
;*** Document No.   : 8443.104.02.003
;*** Document Date  : 2002-10-25
;*** Document Status: SUBMITTED
;*** Document Author: TML
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:48:12 2007"
PRAGMA 	LAST_MODIFIED 	"2002-10-25"
PRAGMA 	ID_AND_VERSION 	"8443.104.02.003"



CONST 	L_MAX_CALLED_BCD_NO_LENGTH 	10 	; Max Bcd number length (digits)
CONST 	CURSOR_SMS_TEXT_140 	140 	; Position SMS Message



VALTAB 	VAL_data_valid
VAL 	0 	DATA_VALID 	""
VAL 	1 	DATA_INVALID 	""




VAR 	reference 	"Reference" 	S


VAR 	bcd 	"Bcd Number" 	B


VAR 	data_valid 	"Cursor Data Valid" 	B

VAL 	@p_mnlc - VAL_data_valid@ 	

VAR 	number_length 	"Number of decimal digits in the Bcd number" 	B


VAR 	sms_text 	"SMS text" 	B





COMP 	called_party_bcd_num 	 "called Party Bcd number"
{
 	number_length 	 ; Number Length
 	bcd 	[L_MAX_CALLED_BCD_NO_LENGTH] 	 ; Bcd Number
}






; MNLC_SMS_MEAS_REQ 	0x80000044
; MNLC_SMS_MEAS_CNF 	0x80004044



PRIM 	MNLC_SMS_MEAS_REQ 	0x80000044
{
 	reference 	 ; Reference SMS request
 	called_party_bcd_num 	 ; Called Bcd Number
}






PRIM 	MNLC_SMS_MEAS_CNF 	0x80004044
{
 	reference 	 ; Reference SMS request
 	data_valid 	 ; Cursor Data Valid
 	sms_text 	[CURSOR_SMS_TEXT_140] 	 ; Cursor SMS
}