view src/ui3/mfw/mfw_sima.c @ 636:57e67ca2e1cb

pcmdata.c: default +CGMI to "FreeCalypso" and +CGMM to model The present change has no effect whatsoever on Falconia-made and Openmoko-made devices on which /pcm/CGMI and /pcm/CGMM files have been programmed in FFS with sensible ID strings by the respective factories, but what should AT+CGMI and AT+CGMM queries return when the device is a Huawei GTM900 or Tango modem that has been converted to FreeCalypso with a firmware change? Before the present change they would return compiled-in defaults of "<manufacturer>" and "<model>", respectively; with the present change the firmware will self-identify as "FreeCalypso GTM900-FC" or "FreeCalypso Tango" on the two respective targets. This firmware identification will become important if someone incorporates an FC-converted GTM900 or Tango modem into a ZeroPhone-style smartphone where some high-level software like ofono will be talking to the modem and will need to properly identify this modem as FreeCalypso, as opposed to some other AT command modem flavor with different quirks. In technical terms, the compiled-in default for the AT+CGMI query (which will always be overridden by the /pcm/CGMI file in FFS if one is present) is now "FreeCalypso" in all configs on all targets; the compiled-in default for the AT+CGMM query (likewise always overridden by /pcm/CGMM if present) is "GTM900-FC" if CONFIG_TARGET_GTM900 or "Tango" if CONFIG_TARGET_TANGO or the original default of "<model>" otherwise.
author Mychaela Falconia <falcon@freecalypso.org>
date Sun, 19 Jan 2020 20:14:58 +0000
parents e8ddbb0837ed
children
line wrap: on
line source

/*
+--------------------------------------------------------------------+
| PROJECT: MMI-Framework (8417)         $Workfile:: mfw_sima.c      $|
| $Author:: Es                          $Revision::  1              $|
| CREATED: 13.10.98                     $Modtime:: 2.03.00 15:14    $|
| STATE  : code                                                      |
+--------------------------------------------------------------------+

   MODULE  : MFW_SIMA

   PURPOSE : This modul contains the functions for SIM management.

	Jan 16, 2006 DR: OMAPS00061460 - Shashi Shekar B.S.
	Description: SAT Icon support
	Solution : SAT icon support added.

*/


#define ENTITY_MFW

#include "mfw_sys.h"

#if defined (NEW_FRAME)

#include "typedefs.h"
#include "vsi.h"
#include "custom.h"
#include "gsm.h"

#else

#include "STDDEFS.H"
#include "custom.h"
#include "gsm.h"
#include "vsi.h"

#endif

#include "prim.h"

#include "message.h"
#include "prim.h"
#include "aci_cmh.h"
#include "prim.h"
#ifndef PCM_2_FFS
#include "pcm.h"
#endif


#include "psa.h"
#include "psa_sim.h"

#include "mfw_mfw.h"
#include "mfw_nm.h"
#include "mfw_sim.h"
#include "mfw_simi.h"
#include "mfw_sima.h"
#include "mfw_nmi.h"
#include "mfw_phb.h"
#include "mfw_cm.h"
#include "mfw_cmi.h"
// Shashi Shekar B.S., a0876501, Jan 16, 2006, DR: OMAPS00061460
#ifdef FF_MMI_SAT_ICON
#include "mfw_sat.h"
#endif

#ifndef FF_2TO1_PS
#include "p_sim.val"
#endif

#include <string.h>

#define hCommSIM _ENTITY_PREFIXED(hCommSIM)
#if defined (NEW_FRAME)
EXTERN T_HANDLE      hCommSIM;        /* SIM    Communication       */
#else
EXTERN T_VSI_CHANDLE hCommSIM;        /* SIM    Communication       */
#endif

EXTERN void          aci_create (BOOL (*r_cb)(USHORT opc, void * data),
                                 BOOL (*cmd)(char *));

/* Added to remove warning Aug - 11 */
#ifdef NEPTUNE_BOARD
EXTERN void sim_signal (MfwEvt event, void *para);
#endif  /* NEPTUNE_BOARD */
/* End - remove warning Aug - 11 */

    
T_MFW_READ_CALLBACK read_callback_data;

// Shashi Shekar B.S., a0876501, Jan 16, 2006, DR: OMAPS00061460
#ifdef FF_MMI_SAT_ICON
EXTERN U8 read_image_instance_file;
#endif

/*
+--------------------------------------------------------------------+
| PROJECT: MMI-Framework (8417)         MODULE: MFW_SIMA             |
| STATE  : code                         ROUTINE: sima_response_cb    |
+--------------------------------------------------------------------+

   PURPOSE : Response Callback Handler.

*/

GLOBAL BOOL sima_response_cb (ULONG opc, void * data)
{
//  TRACE_FUNCTION ("sim_response_cb()");

  switch (opc)
  {
    case SIM_MMI_INSERT_IND:
      /* MMI relevant parameters from the SIM card has received. */
      rAT_PlusCFUNP ((T_SIM_MMI_INSERT_IND *)data);
      return FALSE;   /* processed also by ACI */

    case SIM_ACTIVATE_CNF:
      sim_mmi_parameter((T_SIM_ACTIVATE_CNF *)data);
      return FALSE;

    case SIM_ACTIVATE_IND:
      sim_mmi_update_parameter((T_SIM_ACTIVATE_IND *)data);
      return FALSE;
  }

  return FALSE;       /* not processed by extension */
}

/*
+--------------------------------------------------------------------+
| PROJECT: MMI-Framework (8417)         MODULE: MFW_SIMA             |
| STATE  : code                         ROUTINE: sima_init           |
+--------------------------------------------------------------------+

   PURPOSE : Install AT-Command Extension.

*/

void sima_init ()
{
  TRACE_FUNCTION ("sima_init()");
}


/*
+----------------------------------------------------------------------+
| PROJECT: MMI-Framework (8417)         MODULE: MFW_SIMA               |
| STATE  : code                         ROUTINE: sim_read_sim          |
+----------------------------------------------------------------------+


   PURPOSE :   Request to read SIM card.

*/

void sim_read_sim(USHORT data_id, UBYTE len, UBYTE max_length)
{
  SHORT table_id;

  TRACE_FUNCTION ("sim_read_sim()");

  table_id = psaSIM_atbNewEntry();

  if(table_id NEQ NO_ENTRY)
  {
    simShrdPrm.atb[table_id].ntryUsdFlg = TRUE;
    simShrdPrm.atb[table_id].accType    = ACT_RD_DAT;
    // R99 SIM Interface changes . Indicates whether path_info variable has valid values 
    simShrdPrm.atb[table_id].v_path_info  = FALSE;
    simShrdPrm.atb[table_id].reqDataFld = data_id;
    simShrdPrm.atb[table_id].dataOff    = 0;
    simShrdPrm.atb[table_id].dataLen    = len;
    simShrdPrm.atb[table_id].recMax     = max_length;
    simShrdPrm.atb[table_id].exchData   = NULL;
    simShrdPrm.atb[table_id].rplyCB     = sim_read_sim_cb;

    simShrdPrm.aId = table_id;

    if(psaSIM_AccessSIMData( ) < 0)
    {
      TRACE_EVENT("FATAL ERROR");
    }
  }
}

// Shashi Shekar B.S., a0876501, Jan 16, 2006, DR: OMAPS00061460
#ifdef FF_MMI_SAT_ICON
/*
+----------------------------------------------------------------------+
| PROJECT: MMI-Framework (8417)         MODULE: MFW_SIMA               |
| STATE  : code                         ROUTINE: sim_read_sim_icon     |
+----------------------------------------------------------------------+


   PURPOSE :   Request to read SIM card EF IMG. This is separated from the 
			   above SIM read function as we have to specify the record number 
			   also while reading the EF record & we dont want this functionality 
			   for Lite variants.

*/

void sim_read_sim_icon(T_SIM_ACCESS_PARAM *sim_icon_read_param)
{
  SHORT table_id;

  TRACE_FUNCTION ("sim_read_sim_icon()");

  table_id = psaSIM_atbNewEntry();

  if(table_id NEQ NO_ENTRY)
  {
    simShrdPrm.atb[table_id].ntryUsdFlg = TRUE;
    simShrdPrm.atb[table_id].accType    = ACT_RD_REC;
    // R99 SIM Interface changes. Indicates whether path_info variable has valid values 
    simShrdPrm.atb[table_id].v_path_info  = FALSE;
    simShrdPrm.atb[table_id].reqDataFld = sim_icon_read_param -> data_id;
    simShrdPrm.atb[table_id].dataOff    = sim_icon_read_param -> offset;
    simShrdPrm.atb[table_id].dataLen    = sim_icon_read_param -> len;
    simShrdPrm.atb[table_id].recMax     = sim_icon_read_param -> max_length;
    simShrdPrm.atb[table_id].exchData   = NULL;
	/* Read the Record number provided, only if available */
	if(sim_icon_read_param -> record_number)
    simShrdPrm.atb[table_id].recNr      = sim_icon_read_param -> record_number;
    simShrdPrm.atb[table_id].rplyCB     = sim_read_sim_cb;

    simShrdPrm.aId = table_id;

    if(psaSIM_AccessSIMData( ) < 0)
    {
      TRACE_EVENT("FATAL ERROR");
    }
  }
}
#endif

/*
+---------------------------------------------------------------------+
| PROJECT: MMI-Framework (8417)         MODULE: MFW_SIMA              |
| STATE  : code                         ROUTINE: sim_read_sim_cb      |
+---------------------------------------------------------------------+


   PURPOSE :   Call back for SIM read.

*/

void sim_read_sim_cb(SHORT table_id)
{
  TRACE_FUNCTION ("sim_read_sim_cb()");

  simShrdPrm.atb[table_id].ntryUsdFlg = FALSE;

// Shashi Shekar B.S., a0876501, Jan 16, 2006, DR: OMAPS00061460
#ifdef FF_MMI_SAT_ICON
    /* If we are reading the image data contents, 
    we dont need to enter the switch statement */
    if (read_image_instance_file)
	{
		sim_img_instance_data_cnf(simShrdPrm.atb[table_id].errCode, 
			simShrdPrm.atb[table_id].exchData);
        return;
	}
#endif

  switch (simShrdPrm.atb[table_id].reqDataFld)
  {
// Shashi Shekar B.S., a0876501, Jan 16, 2006, DR: OMAPS00061460
#ifdef FF_MMI_SAT_ICON
    /* EF-IMG contents */
    case SIM_IMG:
      sim_img_cnf(simShrdPrm.atb[table_id].errCode, simShrdPrm.atb[table_id].recNr, 
		  (UBYTE *)simShrdPrm.atb[table_id].exchData);
      break;
#endif

    /* Service provide name */
    case SIM_SPN:
      nm_spn_cnf(simShrdPrm.atb[table_id].errCode, (T_EF_SPN *)simShrdPrm.atb[table_id].exchData);
      break;

    /* group identifier level 1 */
    case SIM_GID1:
      sim_gid1_cnf(simShrdPrm.atb[table_id].errCode, simShrdPrm.atb[table_id].exchData);
      break;

    /* group identifier level 2 */
    case SIM_GID2:
      sim_gid2_cnf(simShrdPrm.atb[table_id].errCode, simShrdPrm.atb[table_id].exchData);
      break;

    case SIM_SST:
      sim_read_sst_cnf(simShrdPrm.atb[table_id].errCode, simShrdPrm.atb[table_id].exchData);
      break;
	/*MC CONQ5862, 13/06/02*, if not one of above data fileds, send event to MMI*/
    default:
    	read_callback_data.error_code = simShrdPrm.atb[table_id].errCode;
    	read_callback_data.read_buffer = simShrdPrm.atb[table_id].exchData;
    	sim_signal(E_SIM_READ_CALLBACK, (void*)&read_callback_data);
      break;
  }
}


/*
+----------------------------------------------------------------------+
| PROJECT: MMI-Framework (8417)         MODULE: MFW_SIMA               |
| STATE  : code                         ROUTINE: sim_write_sim         |
+----------------------------------------------------------------------+


   PURPOSE :   Request to write SIM card.

*/

void sim_write_sim(USHORT data_id, UBYTE *data, UBYTE length)
{
  SHORT table_id;

  /* Write preferred PLMN list in SIM card */
  table_id = psaSIM_atbNewEntry();

  if(table_id NEQ NO_ENTRY)
  {
    simShrdPrm.atb[table_id].ntryUsdFlg = TRUE;
    simShrdPrm.atb[table_id].accType    = ACT_WR_DAT;
    //R99 Sim Interface changes. Indicates whether path_info variable has valid values 
    simShrdPrm.atb[table_id].v_path_info  = FALSE;
    simShrdPrm.atb[table_id].reqDataFld = data_id;
    simShrdPrm.atb[table_id].dataOff    = 0;
    simShrdPrm.atb[table_id].dataLen    = length;
    simShrdPrm.atb[table_id].exchData   = data;
    simShrdPrm.atb[table_id].rplyCB     = sim_write_sim_cb;

    simShrdPrm.aId = table_id;

    if(psaSIM_AccessSIMData( ) < 0)
    {
      TRACE_EVENT("FATAL ERROR");
    }
  }
}


/*
+---------------------------------------------------------------------+
| PROJECT: MMI-Framework (8417)         MODULE: MFW_SIMA              |
| STATE  : code                         ROUTINE: sim_write_sim_cb     |
+---------------------------------------------------------------------+


   PURPOSE :   Call back for SIM write.

*/

void sim_write_sim_cb(SHORT table_id)
{
  simShrdPrm.atb[table_id].ntryUsdFlg = FALSE;

#ifdef FF_2TO1_PS
  if (simShrdPrm.atb[table_id].errCode EQ CAUSE_SIM_NO_ERROR)
#else
  if (simShrdPrm.atb[table_id].errCode EQ SIM_NO_ERROR)
#endif
  {
    TRACE_EVENT("FATAL ERROR");
  }
}