FreeCalypso > hg > fc-magnetite
view cdg-hybrid/sap/t30.pdf @ 463:712c5cc0b2a9
doc/Handset-goal: update for the current situation
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Tue, 20 Mar 2018 01:29:44 +0000 |
parents | e7a67accfad9 |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : t30.pdf ;*** Creation : Wed Mar 11 09:58:51 CST 2009 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : t30 ;*** Document No. : 8411.104.98.312 ;*** Document Date : 2002-04-23 ;*** Document Status: BEING_PROCESSED ;*** Document Author: slo ;******************************************************************************** PRAGMA SRC_FILE_TIME "Thu Nov 29 09:54:28 2007" PRAGMA LAST_MODIFIED "2002-04-23" PRAGMA ID_AND_VERSION "8411.104.98.312" CONST CSI_LEN 20 ; length of CSI field CONST NSF_LEN 90 ; length of NSF field CONST CIG_LEN 20 ; length of CIG field CONST NSC_LEN 90 ; length of NSC field CONST TSI_LEN 20 ; length of TSI field CONST NSS_LEN 90 ; length of NSS field CONST PWD_LEN 20 ; length of PWD field CONST SUB_LEN 20 ; length of SUB field CONST SEP_LEN 20 ; length of SEP field CONST T30_ENTITY_NAME_LEN 6 ; maximum length of entity name including NULL VALTAB VAL_dir VAL 0x00 DIR_SND "send fax data" VAL 0x01 DIR_RCV "receive fax data" VALTAB VAL_sgn VAL 0x00 SGN_OK "OK" VAL 0x01 SGN_DIS "Digital identification signal" VAL 0x02 SGN_CSI "Called subscriber identification" VAL 0x04 SGN_NSF "Non-standard facilities" VAL 0x21 SGN_CFR "Confirmation to receive" VAL 0x22 SGN_FTT "Failure to train" VAL 0x31 SGN_MCF "Message confirmation" VAL 0x32 SGN_RTN "Retrain negative" VAL 0x33 SGN_RTP "Retrain positive" VAL 0x34 SGN_PIN "Procedure interrupt negative" VAL 0x35 SGN_PIP "Procedure interrupt positive" VAL 0x3F SGN_FDM "File diagnostics message" VAL 0x41 SGN_DCS "Digital command signal" VAL 0x42 SGN_TSI "Transmitting subscriber identification" VAL 0x43 SGN_SUB "Subaddress" VAL 0x44 SGN_NSS "Non-standard set-up" VAL 0x45 SGN_PWDR "Password - receive" VAL 0x4F SGN_TCF "Training check frame" VAL 0x58 SGN_CRP "Command repeat" VAL 0x5F SGN_DCN "Disconnect" VAL 0x71 SGN_EOM "End of message" VAL 0x72 SGN_MPS "Multi-page signal" VAL 0x74 SGN_EOP "End of procedure" VAL 0x79 SGN_PRI_EOM "Procedure Interrupt - End Of Message" VAL 0x7A SGN_PRI_MPS "Procedure Interrupt - MultiPage Signal" VAL 0x7C SGN_PRI_EOP "Procedure Interrupt - End Of Procedure" VAL 0x81 SGN_DTC "Digital transmit command" VAL 0x82 SGN_CIG "Calling subscriber identification" VAL 0x83 SGN_PWDS "Password - send" VAL 0x84 SGN_NSC "Non-standard facilities command" VAL 0x85 SGN_SEP "Selective Polling" VAL 0xF1 SGN_FCS_ERR "FCS error" VAL 0xF2 SGN_NO_RES "No response" VAL 0xF3 SGN_CONT "continue" VAL 0xFF SGN_NOT_USED "Not used" VALTAB VAL_cmpl VAL 0 CMPL_EOP "end of procedure" VAL 1 CMPL_EOM "end of message" VAL 2 CMPL_PI "procedure interrupt" VAL 3 CMPL_DCN "disconnect" VALTAB VAL_cause VAL 0x4D10 ERR_PH_A_UNSPEC "unspecified phase A error" VAL 0x4D11 ERR_PH_A_T1_TIMEOUT "no answer (T30 T1 timeout)" VAL 0x4D20 ERR_PH_B_SND_UNSPEC "unspecified transmit phase B error" VAL 0x4D21 ERR_PH_B_SND_CANT_RCV_OR_SND "remote cannot receive or send" VAL 0x4D22 ERR_PH_B_SND_COMREC "COMREC error in transmit phase B" VAL 0x4D23 ERR_PH_B_SND_COMREC_INVALID_CMD_RCVD "COMREC invalid command received" VAL 0x4D24 ERR_PH_B_SND_RSPREC "RSPREC transmit error phase B" VAL 0x4D25 ERR_PH_B_SND_DCS_RPTD_3_TIMES "DCS send three times without response" VAL 0x4D26 ERR_PH_B_SND_DIS_DTC_RCVD_3_TIMES "DIS/DTC received 3 times; DCS not recognized" VAL 0x4D27 ERR_PH_B_SND_FTT_2400 "failure to train at 2400 bit/s or +FMS value" VAL 0x4D28 ERR_PH_B_SND_INVALID_RESP_RCVD "invalid respones received" VAL 0x4D40 ERR_PH_C_SND_UNSPEC "unspecified transmit phase C error" VAL 0x4D41 ERR_PH_C_SND_UNSPEC_IMAGE_CONV "unspecified image format error" VAL 0x4D43 ERR_PH_C_SND_DTE_TO_DTC_DATA_UNDERFLOW "DTE to DTC data underflow" VAL 0x4D44 ERR_PH_C_SND_UNRECOG_TRANSP_DATA_CMD "unrecognized transparent data command" VAL 0x4D45 ERR_PH_C_SND_IMAGE_LINE_LENGTH "image error, line length wrong" VAL 0x4D46 ERR_PH_C_SND_IMAGE_PAGE_LENGTH "image error, page length wrong" VAL 0x4D47 ERR_PH_C_SND_IMAGE_COMPRESSION_MODE "image error, compression mode wrong" VAL 0x4D50 ERR_PH_D_SND_UNSPEC "unspecified transmit phase D error" VAL 0x4D51 ERR_PH_D_SND_RSPREC "RESPREC transmit error phase D" VAL 0x4D52 ERR_PH_D_SND_MPS_RPTD_3_TIMES "no response to MPS repeated 3 times" VAL 0x4D53 ERR_PH_D_SND_INVALID_RESP_TO_MPS "invalid respones to MPS" VAL 0x4D54 ERR_PH_D_SND_EOP_RPTD_3_TIMES "no response to EOP repeated 3 times" VAL 0x4D55 ERR_PH_D_SND_INVALID_RESP_TO_EOP "invalid response to EOP" VAL 0x4D56 ERR_PH_D_SND_EOM_RPTD_3_TIMES "no response to EOM repeated 3 times" VAL 0x4D57 ERR_PH_D_SND_INVALID_RESP_TO_EOM "invalid response to EOM" VAL 0x4D58 ERR_PH_D_SND_UNABLE_TO_CONT "unable to continue after PIN or PIP" VAL 0x4D70 ERR_PH_B_RCV_UNSPEC "unspecified receive phase B error" VAL 0x4D71 ERR_PH_B_RCV_RSPREC "RSPREC receive error phase B" VAL 0x4D72 ERR_PH_B_RCV_COMREC "COMREC error in receive phase B" VAL 0x4D73 ERR_PH_B_RCV_EXP_PAGE_NOT_RCVD "T30 T2 timeout, expected page not received" VAL 0x4D74 ERR_PH_B_RCV_T1_TIMEOUT_AFTER_EOM_RCVD "T30 T1 timeout after EOM received" VAL 0x4D90 ERR_PH_C_RCV_UNSPEC "unspecified receive phase C error" VAL 0x4D91 ERR_PH_C_RCV_EOL_MISSING "missing EOL after 5 seconds (3.2/T4)" VAL 0x4D93 ERR_PH_C_RCV_DCE_TO_DTE_BUFFER_OVERFLOW "DCE to DTE buffer overflow" VAL 0x4D94 ERR_PH_C_RCV_BAD_CRC_OR_FRAME "bad crc or frame (ECM mode)" VAL 0x4DA0 ERR_PH_D_RCV_UNSPEC "unspecified receive phase D error" VAL 0x4DA1 ERR_PH_D_RCV_RSPREC_INVALID_RESP_RCVD "RSPREC invalid respones received" VAL 0x4DA2 ERR_PH_D_RCV_COMREC_INVALID_RESP_RCVD "COMREC invalid respones received" VAL 0x4DA3 ERR_PH_D_RCV_UNABLE_TO_CONT "unable to continue after PIN or PIP" VAL 0xCDE0 ERR_PH_B_SND_RESERVED1 "reserved" VAL 0xCDE1 ERR_PH_B_SND_RESERVED2 "reserved" VAL 0xCDE2 ERR_PH_B_SND_RESERVED3 "reserved" VAL 0xCDE3 ERR_PH_C_SND_RESERVED1 "reserved" VAL 0xCDE4 ERR_PH_C_SND_RESERVED2 "reserved" VAL 0xCDE5 ERR_PH_D_SND_RESERVED1 "reserved" VAL 0xCDE6 ERR_PH_D_SND_RESERVED2 "reserved" VAL 0xCDE7 ERR_PH_D_SND_RESERVED3 "reserved" VAL 0xCDE8 ERR_PH_B_RCV_NO_RESP "T2 timeout, no response" VAL 0xCDE9 ERR_PH_B_RCV_INVALID_RESP_RCVD "invalid respones received" VAL 0xCDEA ERR_PH_B_RCV_RESERVED3 "reserved" VAL 0xCDEB ERR_PH_C_RCV_RESERVED1 "reserved" VAL 0xCDEC ERR_PH_C_RCV_RESERVED2 "reserved" VAL 0xCDED ERR_PH_D_RCV_NO_RESP "T2 timeout, no response" VAL 0xCDEE ERR_PH_D_RCV_INVALID_RESP_RCVD "invalid respones received" VAL 0xCDEF ERR_PH_D_RCV_RESERVED3 "reserved" VAL 0xCDF0 ERR_SGN_NOT_ALLOWED "signal not allowed" VAL 0xCDF1 ERR_CCD_ENC "CCD encoding error" VALTAB VAL_test_mode VAL 0 TST_OFF "normal" VAL 0x0001 TST_BCS "test BCS formatter only" VAL 0x0002 TST_STUFF "stuffing/destuffing off" VAL 0x0004 TST_FCS "FCS generating/checking off" VAL 0x0008 TST_CTRL "Control checking off" VAL 0x0010 TST_RTC "RTC checking off" VAL 0x0020 TST_MIR "mirror report strings" VAL 0x0080 TST_BUF "show contents of buffer" VALTAB VAL_bitorder VAL 0 FBO_NRM_DATA "no change in bitorder for DATA frames" VAL 0 FBO_NRM_STATUS "no change in bitorder for STATUS frames" VAL 1 FBO_REV_DATA "reverse bitorder only for MSG frames" VAL 2 FBO_REV_STATUS "reverse bitorder only for STATUS frames" VALTAB VAL_phase VAL 0 BCS_PHASE "Not a message phase" VAL 1 MSG_PHASE "Message phase (C)" VALTAB VAL_dti_conn VAL 0 T30_DISCONNECT_DTI "Disconnect DTI from T30" VAL 1 T30_CONNECT_DTI "Connect DTI to T30" VALTAB VAL_link_id VAL 0 T30_LINK_ID_DEFAULT "Default link id" VALTAB VAL_dti_direction VAL 0 T30_DTI_NORMAL "DTI used normally" VAL 1 T30_DTI_INVERTED "DTI is inverted" VAR crp "CRP flag" B VAR c_pwd "length of PWD" B VAR pwd "password" B VAR c_sub "length of SUB" B VAR sub "subaddress" B VAR c_sep "length of SEP" B VAR sep "selective polling" B VAR c_nsc "length of NSC" B VAR nsc "non-standard facilities command" B VAR c_nsf "length of NSF" B VAR nsf "non-standard facilities" B VAR c_tsi "length of TSI" B VAR tsi "transmitting subscriber identification" B VAR c_cig "length of CIG" B VAR cig "calling subscriber identification" B VAR c_csi "length of CSI" B VAR csi "calling subscriber identification" B VAR c_nss "length of NSS" B VAR nss "non-standard set-up" B VAR v_dis "DIS flag" B VAR v_dcs "DCS flag" B VAR v_dtc "DTC flag" B VAR v8 "V.8 capabilities" B VAR n_byte "no. of octets preferred" B VAR ready_tx_fax "ready to transmit a facsimile document (polling)" B VAR rec_fax_op "receiver fax operation" B VAR data_sig_rate "data signalling rate" B VAR R8_lines_pels "R8*7.7 lines/mm and/or 200 x 200 pels/25.4 mm" B VAR two_dim_coding "two-dimensional coding" B VAR rec_width "recording-width" B VAR max_rec_len "maximum recording length" B VAR min_scan_time "minimum scan line time at the receiver" B VAR uncomp_mode "uncompressed mode" B VAR err_corr_mode "error correction mode" B VAR frame_size "frame size" B VAR t6_coding "T.6 coding" B VAR R8_lines "R8*15.4 lines/mm" B VAR r_300_pels "300*300 pels/25.4 mm" B VAR R16_lines_pels "R16*15.4 lines/mm and/or 400*400 pels/25.4 mm" B VAR resolution_type "resolution type selection" B VAR i_res_pref "inch based resolution preferred" B VAR m_res_pref "metric-based resolution preferred" B VAR min_scan_time_hr "minimum scan line time for higher resolutions" B VAR sel_polling "selective polling" B VAR subaddr "subaddressing" B VAR password "password" B VAR ready_tx_doc "ready to transmit a data file (polling)" B VAR bft "Binary File Transfer (BFT)" B VAR dtm "Document Transfer Mode (DTM)" B VAR edi "Electronic Data Interchange (EDI)" B VAR btm "Basic Transfer Mode (BTM)" B VAR ready_tx_mixed "ready to transmit a character or mixed mode document (polling)" B VAR char_mode "character mode" B VAR mixed_mode "mixed mode (Annex E/T.4)" B VAR proc_mode_26 "processable mode 26)" B VAR dig_network_cap "digital network capability" B VAR duplex "duplex and half duplex capabilities" B VAR jpeg "JPEG coding" B VAR full_colour "full colour mode" B VAR huffman_tables "preferred Huffman tables" B VAR r_12_bits_pel_comp "12 bits/pel component" B VAR no_subsamp "no subsampling" B VAR cust_illum "custom illuminant" B VAR cust_gamut "custom gamut range" B VAR na_letter "North American Letter (215.9*279.4 mm)" B VAR na_legal "North American Legal (215.9*355.6 mm)" B VAR sing_prog_seq_coding_basic "single-progression sequential coding basic" B VAR sing_prog_seq_coding_L0 "single-progression sequential coding optional L0" B VAR trans_rate "transmission rate" S VAR dir "direction of call" B VAL @p_t30 - VAL_dir@ VAR sgn "binary coded signal" B VAL @p_t30 - VAL_sgn@ VAR hdlc_report "HDLC report mode" B VAR l_buf "length of content in bits" S VAR o_buf "offset of content in bits" S VAR buf "buffer content" B VAR cmpl "completion" B VAL @p_t30 - VAL_cmpl@ VAR cause "error cause" S VAL @p_t30 - VAL_cause@ VAR half_rate "half-rate flag" B VAR threshold "tcf threshold" B VAR frames_per_prim "no. of frames per primitive" S VAR test_mode "Test mode" S VAL @p_t30 - VAL_test_mode@ VAR eol "end of line count" S VAR buf_size_rx "buffer size RX" S VAR buf_size_tx "buffer size TX" S VAR bitorder "Bitorder" B VAL @p_t30 - VAL_bitorder@ VAR phase "T.30 phase" B VAL @p_t30 - VAL_phase@ VAR dti_conn "DTI connect" B VAL @p_t30 - VAL_dti_conn@ VAR entity_name "name of an neighbour entity" B VAR link_id "Link identifier" L VAL @p_t30 - VAL_link_id@ VAR dti_direction "DTI direction" B VAL @p_t30 - VAL_dti_direction@ COMP dis "digital identification signal" { v8 ; V.8 capabilities n_byte ; no. of octets preferred ready_tx_fax ; ready to transmit a facsimile document (polling) rec_fax_op ; receiver fax operation data_sig_rate ; data signalling rate R8_lines_pels ; R8*7.7 lines/mm and/or 200 x 200 pels/25.4 mm two_dim_coding ; two-dimensional coding rec_width ; recording-width max_rec_len ; maximum recording length min_scan_time ; minimum scan line time at the receiver uncomp_mode ; uncompressed mode err_corr_mode ; error correction mode frame_size ; frame size t6_coding ; T.6 coding R8_lines ; R8*15.4 lines/mm r_300_pels ; 300*300 pels/25.4 mm R16_lines_pels ; R16*15.4 lines/mm and/or 400*400 pels/25.4 mm resolution_type ; resolution type selection i_res_pref ; inch based resolution preferred m_res_pref ; metric-based resolution preferred min_scan_time_hr ; minimum scan line time for higher resolutions sel_polling ; selective polling subaddr ; subaddressing password ; password ready_tx_doc ; ready to transmit a data file (polling) bft ; Binary File Transfer (BFT) dtm ; Document Transfer Mode (DTM) edi ; Electronic Data Interchange (EDI) btm ; Basic Transfer Mode (BTM) ready_tx_mixed ; ready to transmit a character or mixed mode document (polling) char_mode ; character mode mixed_mode ; mixed mode (Annex E/T.4) proc_mode_26 ; processable mode 26) dig_network_cap ; digital network capability duplex ; duplex and half duplex capabilities jpeg ; JPEG coding full_colour ; full colour mode huffman_tables ; preferred Huffman tables r_12_bits_pel_comp ; 12 bits/pel component no_subsamp ; no subsampling cust_illum ; custom illuminant cust_gamut ; custom gamut range na_letter ; North American Letter (215.9*279.4 mm) na_legal ; North American Legal (215.9*355.6 mm) sing_prog_seq_coding_basic ; single-progression sequential coding basic sing_prog_seq_coding_L0 ; single-progression sequential coding optional L0 } TYPEDEF COMP dis dtc "digital transmit command" TYPEDEF COMP dis dcs "digital command signal" COMP hdlc_info "HDLC information field" { crp ; CRP flag c_pwd ; length of PWD pwd [PWD_LEN] ; password c_sub ; length of SUB sub [SUB_LEN] ; subaddress c_sep ; length of SEP sep [SEP_LEN] ; selective polling c_nsc ; length of NSC nsc [NSC_LEN] ; non-standard facilities command c_nsf ; length of NSF nsf [NSF_LEN] ; non-standard facilities c_tsi ; length of TSI tsi [TSI_LEN] ; transmitting subscriber identification c_cig ; length of CIG cig [CIG_LEN] ; calling subscriber identification c_csi ; length of CSI csi [CSI_LEN] ; calling subscriber identification c_nss ; length of NSS nss [NSS_LEN] ; non-standard set-up v_dis ; DIS flag dis ; digital identification signal v_dcs ; DCS flag dcs ; digital command signal v_dtc ; DTC flag dtc ; digital transmit command } COMP sdu "Service Data Unit" { l_buf ; length of content in bits o_buf ; offset of content in bits buf [1] ; buffer content } ; T30_ACTIVATE_REQ 0x80000014 ; T30_CONFIG_REQ 0x80010014 ; T30_CAP_IND 0x80004014 ; T30_CAP_REQ 0x80020014 ; T30_DTI_REQ 0x80060014 ; T30_DTI_CNF 0x80094014 ; T30_DTI_IND 0x80084014 ; T30_PHASE_IND 0x800A4014 ; T30_SGN_IND 0x80014014 ; T30_SGN_REQ 0x80030014 ; T30_CMPL_IND 0x80024014 ; T30_REPORT_IND 0x80034014 ; T30_MODIFY_REQ 0x80040014 ; T30_ERROR_IND 0x80044014 ; T30_EOL_IND 0x800B4014 ; T30_DEACTIVATE_REQ 0x80050014 ; T30_DEACTIVATE_CNF 0x80054014 ; T30_ACTIVATE_CNF 0x80064014 ; T30_PREAMBLE_IND 0x80074014 PRIM T30_ACTIVATE_REQ 0x80000014 { trans_rate ; transmission rate half_rate ; half-rate flag threshold ; tcf threshold frames_per_prim ; no. of frames per primitive bitorder ; bitorder } PRIM T30_CONFIG_REQ 0x80010014 { hdlc_report ; HDLC report mode test_mode ; Test mode } PRIM T30_CAP_IND 0x80004014 { hdlc_info ; HDLC information field } PRIM T30_CAP_REQ 0x80020014 { hdlc_info ; HDLC information field } PRIM T30_DTI_REQ 0x80060014 { dti_conn ; DTI connect entity_name [T30_ENTITY_NAME_LEN] ; entity name link_id ; link identifier dti_direction ; DTI direction } PRIM T30_DTI_CNF 0x80094014 { dti_conn ; DTI connect } PRIM T30_DTI_IND 0x80084014 { } PRIM T30_PHASE_IND 0x800A4014 { phase ; T30 Phase } PRIM T30_SGN_IND 0x80014014 { sgn ; binary coded signal } PRIM T30_SGN_REQ 0x80030014 { sgn ; binary coded signal } PRIM T30_CMPL_IND 0x80024014 { cmpl ; complete of phase } PRIM T30_REPORT_IND 0x80034014 { dir ; call direction sdu ; service data unit } PRIM T30_MODIFY_REQ 0x80040014 { trans_rate ; transmission rate half_rate ; half-rate flag } PRIM T30_ERROR_IND 0x80044014 { cause ; error cause } PRIM T30_EOL_IND 0x800B4014 { eol ; end of line count } PRIM T30_DEACTIVATE_REQ 0x80050014 { } PRIM T30_DEACTIVATE_CNF 0x80054014 { } PRIM T30_ACTIVATE_CNF 0x80064014 { buf_size_rx ; buffer size RX buf_size_tx ; buffer size TX } PRIM T30_PREAMBLE_IND 0x80074014 { }