view cdg3/sap/tra.pdf @ 638:cab2f315827e

FFS dev.c: added Spansion PL032J to the "generic" table With the discovery of first GTM900 and then Tango, it now appears that Openmoko was not the only manuf after all who kept TI's TCS211 firmware largely intact (as opposed to changing it beyond all recognition like Compal, Chi-Mei and BenQ did), thus we are now getting new "alien" targets on which we reuse the original manuf's FFS with IMEI and RF calibration tables as if it were native. On these targets we use the original device table for FFS, even though we previously thought that it would never apply to any target other than dsample, leonardo and gtamodem. We have previously added Samsung K5L33xxCAM (a new kind of multi-ID device) to the generic table to support its use in Huawei GTM900-B modules; now we got news that some slightly older GTM900-B specimen used S71PL032J instead, so we are now adding PL032J as well.
author Mychaela Falconia <falcon@freecalypso.org>
date Thu, 30 Jan 2020 17:45:48 +0000
parents c15047b3d00d
children
line wrap: on
line source

;********************************************************************************
;*** File           : tra.pdf
;*** Creation       : Wed Mar 11 09:58:53 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : tra
;*** Document No.   : 8411.106.98.101
;*** Document Date  : 2002-06-10
;*** Document Status: BEING_PROCESSED
;*** Document Author: TVO
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:55:46 2007"
PRAGMA 	LAST_MODIFIED 	"2002-06-10"
PRAGMA 	ID_AND_VERSION 	"8411.106.98.101"






VALTAB 	VAL_entity_name
VAL 	6 	TRA_ENTITY_NAME_LEN 	"Max name length"

VALTAB 	VAL_ack_flg
VAL 	0 	TRA_ACK 	"acknowledged"
VAL 	1 	TRA_NAK 	"not acknowledged"

VALTAB 	VAL_dti_direction
VAL 	0 	TRA_DTI_NORMAL 	"DTI used normally"
VAL 	1 	TRA_DTI_INVERTED 	"DTI is inverted"

VALTAB 	VAL_dti_conn
VAL 	0 	TRA_CONNECT_DTI 	"Connect DTI to TRA"
VAL 	1 	TRA_DISCONNECT_DTI 	"Connect DTI to upper layer"




VAR 	entity_name 	"name of an neighbour entity" 	B

VAL 	@p_tra - VAL_entity_name@ 	

VAR 	ack_flg 	"acknowledge flag" 	B

VAL 	@p_tra - VAL_ack_flg@ 	

VAR 	link_id 	"link identifier" 	L


VAR 	dti_direction 	"DTI direction" 	B

VAL 	@p_tra - VAL_dti_direction@ 	

VAR 	dti_conn 	"DTI connect" 	B

VAL 	@p_tra - VAL_dti_conn@ 	







; TRA_ACTIVATE_REQ 	0x80000019
; TRA_ACTIVATE_CNF 	0x80004019
; TRA_DEACTIVATE_REQ 	0x80010019
; TRA_DEACTIVATE_CNF 	0x80014019
; TRA_DTI_REQ 	0x80020019
; TRA_DTI_CNF 	0x80024019
; TRA_DTI_IND 	0x80034019



PRIM 	TRA_ACTIVATE_REQ 	0x80000019
{
}






PRIM 	TRA_ACTIVATE_CNF 	0x80004019
{
 	ack_flg 	 ; acknowledge flag
}






PRIM 	TRA_DEACTIVATE_REQ 	0x80010019
{
}






PRIM 	TRA_DEACTIVATE_CNF 	0x80014019
{
}






PRIM 	TRA_DTI_REQ 	0x80020019
{
 	dti_conn 	 ; DTI connect
 	link_id 	 ; Link identifier of DTI
 	entity_name 	[TRA_ENTITY_NAME_LEN] 	 ; Communication entity name
 	dti_direction 	 ; DTI direction
}






PRIM 	TRA_DTI_CNF 	0x80024019
{
 	dti_conn 	 ; DTI connect
 	link_id 	 ; Link identifier
}






PRIM 	TRA_DTI_IND 	0x80034019
{
 	link_id 	 ; link identifier
}