FreeCalypso > hg > fc-magnetite
view cdg3/sap/tb.pdf @ 632:d968a3216ba0
new tangomdm build target
TCS211/Magnetite built for target leonardo runs just fine on the Tango-based
Caramel board, but a more proper tangomdm build target is preferable in order
to better market these Tango modems to prospective commercial customers. The
only differences are in GPIO and MCSI config:
* MCSI is enabled in the tangomdm build config.
* GPIO 1 is loudspeaker amplifier control on Leonardo, but on Tango platforms
it can be used for anything. On Caramel boards this GPIO should be
configured as an output driving high.
* GPIO 2 needs to be configured as Calypso input on Leonardo, but on Tango
platforms it can be used for anything. On Caramel boards this GPIO should be
configured as an output, either high or low is OK.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Sat, 04 Jan 2020 19:27:41 +0000 |
parents | c15047b3d00d |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : tb.pdf ;*** Creation : Wed Mar 11 09:58:52 CST 2009 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : tb ;*** Document No. : 8441.112.01.002 ;*** Document Date : 2001-07-17 ;*** Document Status: BEING_PROCESSED ;*** Document Author: SAB ;******************************************************************************** PRAGMA SRC_FILE_TIME "Thu Nov 29 09:54:48 2007" PRAGMA LAST_MODIFIED "2001-07-17" PRAGMA ID_AND_VERSION "8441.112.01.002" CONST TB_BA_LIST_SIZE 33 ; BA list size VALTAB VAL_arfcn VAL 1 - 124 "GSM 900 without extension band" VAL 1 - 174 "GSM 900 with extension band" VAL 512 - 810 "PCS 1900" VAL 512 - 885 "DCS 1800" VAL 1 - 498 "Dual band(GSM/DCS)" VAL 1 - 548 "Dual band(EGSM/DCS)" VAL 0xFFFF TB_INVALID_ARFCN "Used to mark a channel number entry as invalid." VAR num_meas "number" B VAR rxlev "measurement value" S VAR arfcn "channel number" S VAL @p_tb - VAL_arfcn@ VAR sc_rxlev "RXLEV value of the serving cell." B COMP tb_meas_result "" { arfcn ; Channel Number rxlev ; ACC Level num_meas ; ACC nbr } ; TB_MEAS_IND 0x1800 ; TB_RXLEV_SC_REQ 0x5800 PRIM TB_MEAS_IND 0x1800 { tb_meas_result [TB_BA_LIST_SIZE] ; Measurement result } PRIM TB_RXLEV_SC_REQ 0x5800 { sc_rxlev ; RXLEV Serving Cell }