FreeCalypso > hg > fc-magnetite
view src/aci2/aci/aci_bat_err.c @ 433:f6ea8d4a5cd8
components/mfw-tcs3: recipe created, starting to compile
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Mon, 22 Jan 2018 00:43:18 +0000 |
parents | 93999a60b835 |
children |
line wrap: on
line source
/* +----------------------------------------------------------------------------- | Project : GSM-F&D (8411) | Modul : ACI_BAT +----------------------------------------------------------------------------- | Copyright 2002 Texas Instruments Berlin, AG | All rights reserved. | | This file is confidential and a trade secret of Texas | Instruments Berlin, AG | The receipt of or possession of this file does not convey | any rights to reproduce or disclose its contents or to | manufacture, use, or sell anything it may describe, in | whole, or in part, without the specific written consent of | Texas Instruments Berlin, AG. +----------------------------------------------------------------------------- | Purpose : Handle cme and cms errors for BAT clients +----------------------------------------------------------------------------- */ #include "aci_all.h" #include "aci_cmh.h" /* so see T_ACI_ERR_CLASS and other */ #include "psa.h" #include "cmh.h" /* extern definition of aciErrDesc */ #include "aci_bat_cmh.h" #include "aci_bat.h" #include "aci_bat_err.h" #include "psa_psi.h" /* * the [stq]AT_xxx function will set the global variable aciErrDesc with ACI_ERR_DESC. * here we read it and cast it to the BAT value defined in * T_BAT_plus_cme_error_error and T_BAT_plus_cms_error_err. * Currently (03.March 2005) the error values of ACI and BAT are identical, * but can cause a lot of problems when there is a mismatch! * There should be used only the values of p_bat.h defined in bat.sap ! * * on ACI level there are CME, CMS, CEER and EXT error values. * CEER errors are/is only one in * cmh_ccf.c:2159: ACI_ERR_DESC( ACI_ERR_CLASS_Ceer, CAUSE_MAKE(DEFBY_STD, * and must be requested with the * T_BAT_cmd_send send.ctrl_params = BAT_CMD_SET_PLUS_CEER by the apllication. * BAT returns with a T_BAT_res_set_plus_ceer structure. * */ /* +--------------------------------------------------------------------+ | PROJECT : GSM-F&D (8411) MODULE : ACI_BAT | | STATE : code ROUTINE : aci_bat_err | +--------------------------------------------------------------------+ PURPOSE : central BAT error function called by aci_bat_wrapper only. it evaluates the global varaible aciErrDesc, which has been set with the appropriate error value of the just ran ACI function. */ GLOBAL void aci_bat_err (T_ACI_DTI_PRC_PSI *src_infos_psi) { T_ACI_ERR_CLASS err_class; T_BAT_res_plus_cme_error cme_data; T_BAT_res_plus_cms_error cms_data; T_BAT_res_plus_ext_error ext_data; T_BAT_cmd_response resp; if (ACI_BAT_VALID_ERR_DESC()) { err_class = ACI_BAT_GET_ERR_CLASS(); switch (err_class) { case (ACI_ERR_CLASS_Cme): { T_BAT_plus_cme_error_error bat_err; T_ACI_CME_ERR err = ACI_BAT_GET_ERR_VALUE(); ACI_BAT_RESET_ERR_DESC(); bat_err = (T_BAT_plus_cme_error_error)err; resp.ctrl_response = BAT_RES_PLUS_CME_ERROR; resp.response.ptr_plus_cme_error=&cme_data; resp.response.ptr_plus_cme_error->error = bat_err; TRACE_EVENT_P1("aci_bat_err(): CME ERROR: %d", bat_err); break; } case (ACI_ERR_CLASS_Cms): { T_BAT_plus_cms_error_err bat_err; T_ACI_CMS_ERR err = ACI_BAT_GET_ERR_VALUE(); ACI_BAT_RESET_ERR_DESC(); bat_err = (T_BAT_plus_cms_error_err)err; resp.ctrl_response = BAT_RES_PLUS_CMS_ERROR; resp.response.ptr_plus_cms_error=&cms_data; resp.response.ptr_plus_cms_error->err = bat_err; TRACE_EVENT_P1("aci_bat_err(): CMS ERROR: %d", bat_err); break; } case (ACI_ERR_CLASS_Ext): { T_BAT_plus_ext_error_err bat_err; T_ACI_EXT_ERR err = ACI_BAT_GET_ERR_VALUE(); ACI_BAT_RESET_ERR_DESC(); bat_err = (T_BAT_plus_ext_error_err)err; resp.ctrl_response = BAT_RES_PLUS_EXT_ERROR; resp.response.ptr_plus_ext_error=&ext_data; resp.response.ptr_plus_ext_error->err = bat_err; TRACE_EVENT_P1("aci_bat_err(): EXT ERROR: %d", bat_err); break; } case (ACI_ERR_CLASS_NotPresent): default: /* this should trigger to request the CEER errors by the application */ resp.ctrl_response = BAT_RES_PLUS_CME_ERROR; resp.response.ptr_plus_cms_error=&cms_data; resp.response.ptr_plus_cms_error->err=BAT_CME_ERROR_UNKNOWN; TRACE_EVENT("aci_bat_err(): UNKNOWN ERROR"); break; } } else { TRACE_EVENT("aci_bat_err(): WARNING, no error value set!"); resp.ctrl_response = BAT_RES_PLUS_CME_ERROR; resp.response.ptr_plus_cme_error=&cme_data; resp.response.ptr_plus_cme_error->error=BAT_CME_ERROR_UNKNOWN; } aci_bat_send(src_infos_psi,&resp); } /* +--------------------------------------------------------------------+ | PROJECT : GSM-F&D (8411) MODULE : ACI_BAT | | STATE : code ROUTINE : sBAT_PlusCEER | +--------------------------------------------------------------------+ PURPOSE : */ GLOBAL T_ACI_BAT_RSLT sBAT_PlusCEER (T_ACI_DTI_PRC_PSI *src_infos_psi, T_BAT_cmd_send *cmd) { T_ACI_BAT_RSLT ret; USHORT cause; TRACE_FUNCTION ("sBAT_PlusCEER()"); /* * Call the corresponding ACI function. T_ACI_BAT_RSLT is * assumed to be equivalent to T_ACI_RESULT. */ ret=(T_ACI_BAT_RSLT)qAT_PlusCEER(src_infos_psi->srcId,&cause); /* * If the query completes - and it should - send the response now. */ if (ret==ACI_BAT_CMPL) { T_BAT_cmd_response resp; T_BAT_res_set_plus_ceer ceer_data; resp.ctrl_response=BAT_RES_SET_PLUS_CEER; resp.response.ptr_set_plus_ceer=&ceer_data; ceer_data.definedby=(T_BAT_plus_ceer_definedby)GET_CAUSE_DEFBY(cause); ceer_data.originatingside=(T_BAT_plus_ceer_originatingside)GET_CAUSE_ORIGSIDE(cause); ceer_data.originatingentity=(T_BAT_plus_ceer_originatingentity)GET_CAUSE_ORIGIN_ENTITY(cause); ceer_data.causevalue=(U8)GET_CAUSE_VALUE(cause); aci_bat_send(src_infos_psi,&resp); } return(ret); }