FreeCalypso > hg > fc-rfcal-tools
diff doc/Tx-cal-theory @ 66:8e675142cca7
doc/Tx-cal-theory written
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Sun, 28 May 2017 06:42:29 +0000 |
parents | |
children | 615df2fb1ec3 |
line wrap: on
line diff
--- /dev/null Thu Jan 01 00:00:00 1970 +0000 +++ b/doc/Tx-cal-theory Sun May 28 06:42:29 2017 +0000 @@ -0,0 +1,70 @@ +The Tx power levels put out by a GSM mobile station are subject to strict +specifications, and on the Calypso+Iota+Rita chipset they are produced by +writing different values into the APC DAC register. But what value should be +written into the APC DAC in order to produce a given Tx power level in dBm? +The answer varies from one produced device unit to the next, and even more from +one board design to the next, hence these APC values need to be calibrated. + +The general procedure for calibrating Tx power levels is described in both Sara +and LoCosto calibration documents (see TI-docs), but the LoCosto document adds +one crucial detail which the Sara one fails to describe. The instructions given +in the Sara document appear to be perfectly intuitive at first: go through all +power levels in turn (PL numbers 5-19 for EGSM and GSM850 or 0-15 for DCS and +PCS), and for each power level command the DUT to transmit at that level, +measure the actual Tx output power with the CMU200 or other RF test equipment, +and adjust the APC DAC value up or down to make the output power match the spec. + +The problem is with the very last part: the output power you get with the +compiled-in APC DAC value is one number, the spec-defined target power is a +different number, exactly how do you adjust the APC DAC value to hit the target +power level? + +The LoCosto document gives the answer which was not at all obvious to me at +first. I draw the reader's attention to section A.3.1 on page 43 of that +document. The trick is as follows: the relation between the APC DAC value and +the resulting Tx output power (or rather the equivalent in terms of voltage) is +modeled as a piecewise linear function, and this piecewise linear function is +constructed from a preliminary set of output power measurements with a fixed +set of APC DAC values. + +We also have a strong piece of evidence that the Tx power level calibration +procedure performed by Openmoko at their factory was based on the same principle +as the LoCosto document version. If you look at the /gsm/rf/tx/levels.900 table +in Om-calibrated GTA02 units and compare it against the firmware's compiled-in +version, you will see that the APC DAC values for power levels 5-19 have been +replaced with calibrated ones as expected, but there is also this oddity: the +APC DAC value for power level 0 (not a valid number for this band) has been +replaced with 600. Always 600, a perfect round number, on every unit. + +Having understood the calibration method described in the LoCosto document, the +mystery of this fixed number 600 becomes clear: the calibration program +establishes the basis for the calibration by temporarily overwriting the APC DAC +value in the power level 0 slot with a series of fixed values, 600 being the +last of them. It constructs the piecewise linear model for the APC from power +measurements made with these fixed DAC values, and uses this model to compute +the DAC value for each target power level. The latter DAC values are then +written into Tx levels table slots 5-19 for EGSM and GSM850, or 0-15 for DCS +and PCS. In the case of DCS and PCS no visible artifacts remain from the +calibration basis run (because slot 0 is a valid power level for these bands), +but an artifact remains in the levels.900 table in the unused slot 0. + +In the present FreeCalypso RF calibration tools suite the planned +fc-rfcal-txband program that will perform the entire Tx band calibration +procedure has not been written yet. Instead we have the following two building +blocks: + +fc-rfcal-txbasis performs the preliminary "basis" step of Tx power level +calibration: it sets the APC DAC to each of the values given on the command line +in turn, and reports the resulting output power level in dBm. The temporary +APC DAC values do get written into the Tx levels table in L1 (there is no other +way to set the APC DAC value for the active transmitter through Test Mode), but +the MISC_ENABLE command to save Tx calibration tables in FFS is NOT issued, +thus the corruption of the Tx levels table inflicted by this program will get +blown away on the next rfpw 7 (Test Mode band selection) command. + +fc-rfcal-txcheck is a completely non-invasive program (does not make any writes +to any L1 RF tables or to FFS) that steps through all power levels for the +specified band (5-19 for EGSM or GSM850, or 0-15 for DCS or PCS), performs a +power measurement at each level, and displays the measured result. An +equivalent operation will be the finishing sanity check step in the full Tx +power level calibration program.