FreeCalypso > hg > fc-selenite
comparison cdg-hybrid/msg/t30.mdf @ 9:6da1d56a96a3
cdg-hybrid: import from Magnetite
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Sun, 15 Jul 2018 21:08:11 +0000 |
parents | |
children |
comparison
equal
deleted
inserted
replaced
8:ed162c9cd29f | 9:6da1d56a96a3 |
---|---|
1 ;******************************************************************************** | |
2 ;*** File : t30.mdf | |
3 ;*** Creation : Thu Jun 19 15:32:14 CST 2008 | |
4 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 | |
5 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 | |
6 ;******************************************************************************** | |
7 ;*** Document Type : Air Interface Message Specification | |
8 ;*** Document Name : t30 | |
9 ;*** Document No. : 8411.620.98.101 | |
10 ;*** Document Date : 2000-02-04 | |
11 ;*** Document Status: BEING_PROCESSED | |
12 ;*** Document Author: UB | |
13 ;******************************************************************************** | |
14 | |
15 | |
16 | |
17 PRAGMA SRC_FILE_TIME "Wed Nov 28 10:21:26 2007" | |
18 PRAGMA LAST_MODIFIED "2000-02-04" | |
19 PRAGMA ID_AND_VERSION "8411.620.98.101" | |
20 | |
21 | |
22 | |
23 CONST MAX_NSF_LEN 720 ; number of bits in non-standard facility element. | |
24 | |
25 | |
26 | |
27 VALTAB VAL_v8 | |
28 VAL 0 v8_not_avail "V.8 is not available" | |
29 VAL 1 v8_avail "V.8 is available" | |
30 | |
31 VALTAB VAL_n_byte | |
32 VAL 0 NB_256_BYTES "256 octets preferred in ECM" | |
33 VAL 1 NB_64_BYTES "64 octets preferred in ECM" | |
34 | |
35 VALTAB VAL_ready_tx_fax | |
36 VAL 0 RTF_NO_TX_RDY "not ready to transmit a facsimile document" | |
37 VAL 1 RTF_TX_RDY "ready to transmit a facsimile document" | |
38 | |
39 VALTAB VAL_rec_fax_op | |
40 VAL 0 RFO_NO_RX_RDY "not ready to receive a facsimile document" | |
41 VAL 1 RFO_RX_RDY "ready to receive a facsimile document" | |
42 | |
43 VALTAB VAL_data_sig_rate | |
44 VAL DEF "undefined signalling rate" | |
45 VAL 0 DSR_2400_V27 "signalling rate 2400 bps V.27 ter" | |
46 VAL 4 DSR_4800_V27 "signalling rate 4800 bps V.27 ter" | |
47 VAL 12 DSR_7200_V29 "signalling rate 7200 bps V.29" | |
48 VAL 13 DSR_7200_V17 "signalling rate 7200 bps V.17" | |
49 VAL 8 DSR_9600_V29 "signalling rate 9600 bps V.29" | |
50 VAL 9 DSR_9600_V17 "signalling rate 9600 bps V.17" | |
51 VAL 5 DSR_12000_V17 "signalling rate 12000 bps V.17" | |
52 VAL 1 DSR_14000_V17 "signalling rate 14400 bps V.19" | |
53 | |
54 VALTAB VAL_R8_lines_pels | |
55 VAL 0 R8LP_R8_ONLY "vertical resolution is specified by R8 only" | |
56 VAL 1 R8LP_R8_EXTENDED "vertical resolution is specified not only by R8" | |
57 | |
58 VALTAB VAL_two_dim_coding | |
59 VAL 0 TDC_NO_2D_CODING "no 2D T.4 coding" | |
60 VAL 1 TDC_2D_CODING "2D T.4 coding" | |
61 | |
62 VALTAB VAL_rec_width | |
63 VAL 0 RW_WIDTH_215_MM "Scan line length of 215 mm" | |
64 VAL 1 RW_WIDTH_303_MM "Scan line length of 215, 255 and 303 mm" | |
65 VAL 2 RW_WIDTH_255_MM "Scan line length of 215 and 255 mm" | |
66 VAL 3 RW_WIDTH_INVALID "Invalid scan line length" | |
67 | |
68 VALTAB VAL_max_rec_len | |
69 VAL 0 MRL_A4 "Maximum recording length A4 (297 mm)" | |
70 VAL 1 MRL_UNLIMITED "Unlimited recording length" | |
71 VAL 2 MRL_B4 "Maximum recording length B4 (364 mm)" | |
72 VAL 3 MRL_INVALID "Invalid recording length" | |
73 | |
74 VALTAB VAL_min_scan_time | |
75 VAL 0 MST_20_MS "20 ms at 3.85 1/mm: T7.7 = T3.85" | |
76 VAL 1 MST_40_MS "40 ms at 3.85 1/mm: T7.7 = T3.85" | |
77 VAL 2 MST_10_MS "10 ms at 3.85 1/mm: T7.7 = T3.85" | |
78 VAL 3 MST_5_MS "5 ms at 3.85 1/mm: T7.7 = T3.85" | |
79 VAL 4 MST_10_MS_HALF "10 ms at 3.85 1/mm: T7.7 = 1/2 T3.85" | |
80 VAL 5 MST_20_MS_HALF "20 ms at 3.85 1/mm: T7.7 = 1/2 T3.85" | |
81 VAL 6 MST_40_MS_HALF "40 ms at 3.85 1/mm: T7.7 = 1/2 T3.85" | |
82 VAL 7 MST_0_MS "0 ms at 3.85 1/mm: T7.7 = T3.85" | |
83 | |
84 VALTAB VAL_uncomp_mode | |
85 VAL 0 UCM_COMPRESSED "T.4 data (can be send)/(are) in compressed mode" | |
86 VAL 1 UCM_UNCOMPRESSED "T.4 data (can be send)/(are) in uncompressed mode" | |
87 | |
88 VALTAB VAL_err_corr_mode | |
89 VAL 0 ECM_OFF "Error correction mode is not possible/off" | |
90 VAL 1 ECM_ON "Error correction mode is possible/on" | |
91 | |
92 VALTAB VAL_t6_coding | |
93 VAL 0 T6_CODING_OFF "T.6 coding is not possible/off" | |
94 VAL 1 T6_CODING_ON "T.6 coding is possible/on" | |
95 | |
96 VALTAB VAL_R8_lines | |
97 VAL 0 R8_LINES_OFF "R8 x 15.4 lines/mm is not possible/off" | |
98 VAL 1 R8_LINES_ON "R8 x 15.4 lines/mm is possible/on" | |
99 | |
100 VALTAB VAL_r_300_pels | |
101 VAL 0 R300_PELS_OFF "Res 300 x 300 pels /25.4 mm is not possible/off" | |
102 VAL 1 R300_PELS_ON "Res 300 x 300 pels /25.4 mm is possible/on" | |
103 | |
104 VALTAB VAL_R16_lines_pels | |
105 VAL 0 R16_LINES_PELS_OFF "R16 x 15.4 lines/mm and/or 400 x 400 pels/24.4 mm mode is not possible/off" | |
106 VAL 1 R16_LINES_PELS_ON "R16 x 15.4 lines/mm and/or 400 x 400 pels/24.4 mm mode is possible/on" | |
107 | |
108 VALTAB VAL_i_res_pref | |
109 VAL 0 IRP_NO_INCH_BASED "Inch-based resolution not preferred" | |
110 VAL 1 IRP_INCH_BASED "Inch-based resolution preferred" | |
111 | |
112 VALTAB VAL_m_res_pref | |
113 VAL 0 IRP_NO_METRIC_BASED "Metric-based resolution not preferred" | |
114 VAL 1 IRP_METRIC_BASED "Metric-based resolution preferred" | |
115 | |
116 VALTAB VAL_min_scan_time_hr | |
117 VAL 0 MST_T154_EQ_T77 "T15.4 = T7.7" | |
118 VAL 1 MST_T154_EQ_HALF_T77 "T15.4 = 0.5 x T7.7" | |
119 | |
120 VALTAB VAL_sel_polling | |
121 VAL 0 SEP_NO_POLLING "Selective polling not possible" | |
122 VAL 1 SEP_POLLING "Selective polling possible" | |
123 | |
124 VALTAB VAL_subaddr | |
125 VAL 0 SA_NO_SUBADDRESSING "Sub-addressing is not possible/intended" | |
126 VAL 1 SA_SUBADDRESSNIG "Sub-addressing is possible/intended" | |
127 | |
128 VALTAB VAL_password | |
129 VAL 0 PW_NO_PASSWORD "Password checking is not possible/intended" | |
130 VAL 1 PW_PASSWORD "Password checking is possible/intended" | |
131 | |
132 VALTAB VAL_ready_tx_doc | |
133 VAL 0 RTD_TX_READY "Ready to transmit a data file" | |
134 VAL 1 RTD_NOT_TX_READY "Not ready to transmit a data file" | |
135 | |
136 VALTAB VAL_bft | |
137 VAL 0 BFT_NO_BIN_FILE_TX "Not possible/intended to transmit a binary file" | |
138 VAL 1 BFT_BIN_FILE_TX "Possibility/intention to transmit a binary file" | |
139 | |
140 VALTAB VAL_dtm | |
141 VAL 0 DTM_NO_DOC_TX_MODE "Not possible/intended to perform the DTM" | |
142 VAL 1 DTM_DOC_TX_MODE "Possibility/intention to perform the DTM" | |
143 | |
144 VALTAB VAL_edi | |
145 VAL 0 EDI_NO_ELEC_DATA_XCHNG "Not possible/intended to perform EDI" | |
146 VAL 1 EDI_ELEC_DATA_XCHNG "Possibility/intention to perform EDI" | |
147 | |
148 VALTAB VAL_btm | |
149 VAL 0 BTM_NO_BASIC_TRANS_MODE "Not possible/intended to perform the BTM" | |
150 VAL 1 BTM_BASIC_TRANS_MODE "Possibility/intention to perform the BTM" | |
151 | |
152 VALTAB VAL_ready_tx_mixed | |
153 VAL 0 RTM_NO_READY_TX_MIXED "Not ready to transmit a character or mixed mode document" | |
154 VAL 1 RTM_READY_TX_MIXED "Ready to transmit a character or mixed mode document" | |
155 | |
156 VALTAB VAL_char_mode | |
157 VAL 0 CM_NO_CHARACTER_MODE "Not possible/intended to perform the character mode" | |
158 VAL 1 CM_CHARACTER_MODE "Possibility/intention to perform the character mode" | |
159 | |
160 VALTAB VAL_mixed_mode | |
161 VAL 0 MM_NO_MIXED_MODE "Not possible/intended to perform the mixed mode" | |
162 VAL 1 MM_MIXED_MODE "Possibility/intention to perform the mixed mode" | |
163 | |
164 VALTAB VAL_proc_mode_26 | |
165 VAL 0 PM_NO_PROC_MODE_26 "Not possible/intended to perform the processable mode 26" | |
166 VAL 1 PM_PROC_MODE_26 "Possibility/intention to perform the processable mode 26" | |
167 | |
168 VALTAB VAL_dig_network_cap | |
169 VAL 0 DNC_NO_DIGITAL_NETWORK "Terminal is not on a digital network" | |
170 VAL 1 DNC_DIGITAL_NETWORK "Terminal is on a digital network" | |
171 | |
172 VALTAB VAL_duplex | |
173 VAL 0 DUP_HALF_DUPLEX "Operate in half duplex mode only" | |
174 VAL 1 DUP_FULL_DUPLEX "Operate in full-duplex or half duplex mode" | |
175 | |
176 VALTAB VAL_jpeg | |
177 VAL 0 JPG_NO_CODING "Not able/intent to code documents in JPEG" | |
178 VAL 1 JPG_CODING "Able/intent to code documents in JPEG" | |
179 | |
180 VALTAB VAL_full_colour | |
181 VAL 0 FC_NO_FULL_COLOR_MODE "Not able/intent to work in full colour mode" | |
182 VAL 1 FC_FULL_COLOR_MODE "Able/intent to work in full colour mode" | |
183 | |
184 VALTAB VAL_r_12_bits_pel_comp | |
185 VAL 0 BPP_8_BITS_PER_PEL "Images must/are digitised with 8 bits/pel" | |
186 VAL 1 BPP_12_BITS_PER_PEL "Images may be/are digitised with up to 12 bits/pel" | |
187 | |
188 VALTAB VAL_no_subsamp | |
189 VAL 0 NS_USE_4_1_1_SUB "Use the 4:1:1 sub-sampling ratio for the chrominance components in the image data" | |
190 VAL 1 NS_NO_SUBSAMPLING "Use no sub-sampling ratio for the chrominance components in the image data" | |
191 | |
192 VALTAB VAL_cust_illum | |
193 VAL 0 CI_USE_D50_ILLUM "Only the standard D50 illuminant for colour images supported/used" | |
194 VAL 1 CI_CUSTOM_ILLUM "Standard D50 illuminant and other illuminants are supported/used for colour images" | |
195 | |
196 VALTAB VAL_cust_gamut | |
197 VAL 0 CG_STD_GAMUT_RNG "Only the default gamut range for colour images supported/used" | |
198 VAL 1 CG_CUST_GAMUT_RNG "Other gamut ranges are supported/used for colour images" | |
199 | |
200 VALTAB VAL_na_letter | |
201 VAL 0 NLT_NO_NORTH_AMERICAN_LETTER "No North American Letter format is supported/used" | |
202 VAL 1 NLT_NORTH_AMERICAN_LETTER "No North American Letter format is supported/used" | |
203 | |
204 VALTAB VAL_na_legal | |
205 VAL 0 NLG_NO_NORTH_AMERICAN_LEGAL "No North American Legal format is supported/used" | |
206 VAL 1 NLG_NORTH_AMERICAN_LEGAL "No North American Legal format is supported/used" | |
207 | |
208 VALTAB VAL_sing_prog_seq_coding_basic | |
209 VAL 0 SPG_NO_SINGLE_PROG_BASIC "No single-progression sequential coding basic is supported/used" | |
210 VAL 1 SPG_SINGLE_PROG_BASIC "Single-progression sequential coding basic is supported/used" | |
211 | |
212 VALTAB VAL_sing_prog_seq_coding_L0 | |
213 VAL 0 SPG_NO_SINGLE_PROG_L0 "No single-progression sequential coding optional L0 is supported/used" | |
214 VAL 1 SPG_SINGLE_PROG_L0 "Single-progression sequential coding optional L0 is supported/used" | |
215 | |
216 VALTAB VAL_frame_size | |
217 VAL 0 FS_256_OCTETS "Frame size of 256 octets is used if ECM is active" | |
218 VAL 1 FS_64_OCTETS "Frame size of 64 octets is used if ECM is active" | |
219 | |
220 VALTAB VAL_resolution_type | |
221 VAL 0 RT_METRIC_BASED "Metric based resolution" | |
222 VAL 1 RT_INCH_BASED "Inch based resolution" | |
223 | |
224 VALTAB VAL_huffman_tables | |
225 VAL 0 HT_NO_HUFFMAN_TABLES "No default Huffman tables used" | |
226 VAL 1 HT_HUFFMAN_TABLES "Default Huffman tables used" | |
227 | |
228 | |
229 | |
230 | |
231 VAR fcf "Facsimile control field" | |
232 8 | |
233 | |
234 | |
235 VAR cld_sub_nr "called subscriber number" | |
236 8 | |
237 | |
238 | |
239 VAR clg_sub_nr "calling subscriber number" | |
240 8 | |
241 | |
242 | |
243 VAR tra_sub_nr "transmitting subscriber number" | |
244 8 | |
245 | |
246 | |
247 VAR pm_sub_addr "Polling mode sub-address" | |
248 8 | |
249 | |
250 | |
251 VAR sub_addr "Sub-address" | |
252 8 | |
253 | |
254 | |
255 VAR non_std_fac "Non-standard facility content" | |
256 MAX_NSF_LEN | |
257 | |
258 | |
259 VAR pm_pword "Password for polling" | |
260 8 | |
261 | |
262 | |
263 VAR sm_pword "Password for sendingf" | |
264 8 | |
265 | |
266 | |
267 VAR v8 "V.8" | |
268 1 | |
269 | |
270 VAL @m_t30 - VAL_v8@ | |
271 | |
272 VAR n_byte "no. of octets preferred" | |
273 1 | |
274 | |
275 VAL @m_t30 - VAL_n_byte@ | |
276 | |
277 VAR ready_tx_fax "Ready to transmit a facsimile document (polling)" | |
278 1 | |
279 | |
280 VAL @m_t30 - VAL_ready_tx_fax@ | |
281 | |
282 VAR rec_fax_op "Receiver fax operation" | |
283 1 | |
284 | |
285 VAL @m_t30 - VAL_rec_fax_op@ | |
286 | |
287 VAR data_sig_rate "data signalling rate" | |
288 4 | |
289 | |
290 VAL @m_t30 - VAL_data_sig_rate@ | |
291 | |
292 VAR R8_lines_pels "R8 x 7.7 lines/mm and/or 200 x 200 pels/25.4 mm" | |
293 1 | |
294 | |
295 VAL @m_t30 - VAL_R8_lines_pels@ | |
296 | |
297 VAR two_dim_coding "two dimensional coding" | |
298 1 | |
299 | |
300 VAL @m_t30 - VAL_two_dim_coding@ | |
301 | |
302 VAR rec_width "recording width" | |
303 2 | |
304 | |
305 VAL @m_t30 - VAL_rec_width@ | |
306 | |
307 VAR max_rec_len "maximum recording length" | |
308 2 | |
309 | |
310 VAL @m_t30 - VAL_max_rec_len@ | |
311 | |
312 VAR min_scan_time "minimum scan line time" | |
313 3 | |
314 | |
315 VAL @m_t30 - VAL_min_scan_time@ | |
316 | |
317 VAR uncomp_mode "uncompressed mode" | |
318 1 | |
319 | |
320 VAL @m_t30 - VAL_uncomp_mode@ | |
321 | |
322 VAR err_corr_mode "error correction mode" | |
323 1 | |
324 | |
325 VAL @m_t30 - VAL_err_corr_mode@ | |
326 | |
327 VAR t6_coding "T6 coding" | |
328 1 | |
329 | |
330 VAL @m_t30 - VAL_t6_coding@ | |
331 | |
332 VAR R8_lines "R8 lines" | |
333 1 | |
334 | |
335 VAL @m_t30 - VAL_R8_lines@ | |
336 | |
337 VAR r_300_pels "Res 300 x 300 pels/25.4 mm" | |
338 1 | |
339 | |
340 VAL @m_t30 - VAL_r_300_pels@ | |
341 | |
342 VAR R16_lines_pels "R16 x 15.4 lines/mm and/or 400 x 400 pels/24.4 mm" | |
343 1 | |
344 | |
345 VAL @m_t30 - VAL_R16_lines_pels@ | |
346 | |
347 VAR i_res_pref "Inch-based resolution preferred" | |
348 1 | |
349 | |
350 VAL @m_t30 - VAL_i_res_pref@ | |
351 | |
352 VAR m_res_pref "Metric-based resolution preferred" | |
353 1 | |
354 | |
355 VAL @m_t30 - VAL_m_res_pref@ | |
356 | |
357 VAR min_scan_time_hr "Minimum scan line time for higher resolutions" | |
358 1 | |
359 | |
360 VAL @m_t30 - VAL_min_scan_time_hr@ | |
361 | |
362 VAR sel_polling "Selective polling" | |
363 1 | |
364 | |
365 VAL @m_t30 - VAL_sel_polling@ | |
366 | |
367 VAR subaddr "Sub-addressing" | |
368 1 | |
369 | |
370 VAL @m_t30 - VAL_subaddr@ | |
371 | |
372 VAR password "Password flag" | |
373 1 | |
374 | |
375 VAL @m_t30 - VAL_password@ | |
376 | |
377 VAR ready_tx_doc "Ready to transmit a data file" | |
378 1 | |
379 | |
380 VAL @m_t30 - VAL_ready_tx_doc@ | |
381 | |
382 VAR bft "Binary file transfer" | |
383 1 | |
384 | |
385 VAL @m_t30 - VAL_bft@ | |
386 | |
387 VAR dtm "Document transfer mode" | |
388 1 | |
389 | |
390 VAL @m_t30 - VAL_dtm@ | |
391 | |
392 VAR edi "Electronic data interchange" | |
393 1 | |
394 | |
395 VAL @m_t30 - VAL_edi@ | |
396 | |
397 VAR btm "Basic transfer mode" | |
398 1 | |
399 | |
400 VAL @m_t30 - VAL_btm@ | |
401 | |
402 VAR ready_tx_mixed "Ready to transmit a character or mixed mode document" | |
403 1 | |
404 | |
405 VAL @m_t30 - VAL_ready_tx_mixed@ | |
406 | |
407 VAR char_mode "Character mode" | |
408 1 | |
409 | |
410 VAL @m_t30 - VAL_char_mode@ | |
411 | |
412 VAR mixed_mode "Mixed mode" | |
413 1 | |
414 | |
415 VAL @m_t30 - VAL_mixed_mode@ | |
416 | |
417 VAR proc_mode_26 "Processable mode" | |
418 1 | |
419 | |
420 VAL @m_t30 - VAL_proc_mode_26@ | |
421 | |
422 VAR dig_network_cap "Digital network capability" | |
423 1 | |
424 | |
425 VAL @m_t30 - VAL_dig_network_cap@ | |
426 | |
427 VAR duplex "Duplex and half duplex capabilities" | |
428 1 | |
429 | |
430 VAL @m_t30 - VAL_duplex@ | |
431 | |
432 VAR jpeg "JPEG coding" | |
433 1 | |
434 | |
435 VAL @m_t30 - VAL_jpeg@ | |
436 | |
437 VAR full_colour "Full color mode" | |
438 1 | |
439 | |
440 VAL @m_t30 - VAL_full_colour@ | |
441 | |
442 VAR r_12_bits_pel_comp "Digitise 12 Bits/pel component" | |
443 1 | |
444 | |
445 VAL @m_t30 - VAL_r_12_bits_pel_comp@ | |
446 | |
447 VAR no_subsamp "No sub-sampling" | |
448 1 | |
449 | |
450 VAL @m_t30 - VAL_no_subsamp@ | |
451 | |
452 VAR cust_illum "Custom illuminant" | |
453 1 | |
454 | |
455 VAL @m_t30 - VAL_cust_illum@ | |
456 | |
457 VAR cust_gamut "Custom gamut range" | |
458 1 | |
459 | |
460 VAL @m_t30 - VAL_cust_gamut@ | |
461 | |
462 VAR na_letter "North American Letter" | |
463 1 | |
464 | |
465 VAL @m_t30 - VAL_na_letter@ | |
466 | |
467 VAR na_legal "North American Legal" | |
468 1 | |
469 | |
470 VAL @m_t30 - VAL_na_legal@ | |
471 | |
472 VAR sing_prog_seq_coding_basic "Single-progression sequential Coding basic" | |
473 1 | |
474 | |
475 VAL @m_t30 - VAL_sing_prog_seq_coding_basic@ | |
476 | |
477 VAR sing_prog_seq_coding_L0 "Single-progression sequential Coding Optional L0" | |
478 1 | |
479 | |
480 VAL @m_t30 - VAL_sing_prog_seq_coding_L0@ | |
481 | |
482 VAR frame_size "Frame size" | |
483 1 | |
484 | |
485 VAL @m_t30 - VAL_frame_size@ | |
486 | |
487 VAR resolution_type "Resolution type selection" | |
488 1 | |
489 | |
490 VAL @m_t30 - VAL_resolution_type@ | |
491 | |
492 VAR huffman_tables "Preferred Huffman tables" | |
493 1 | |
494 | |
495 VAL @m_t30 - VAL_huffman_tables@ | |
496 | |
497 | |
498 | |
499 | |
500 COMP cap0_rcv "Basic facsimile capabilities receiver" | |
501 { | |
502 .00000 ; reserved bits | |
503 v8 ; V.8 | |
504 n_byte ; no. of octets preferred | |
505 .0 ; reserved bits | |
506 ready_tx_fax ; ready to transmit a facsimile document (polling) | |
507 rec_fax_op ; receiver fax operation | |
508 data_sig_rate ; data signalling rate | |
509 R8_lines_pels ; R8 x 7.7 lines/mm and/or 200 x 200 pels/25.4 mm | |
510 two_dim_coding ; two-dimensional coding | |
511 rec_width ; recording-width | |
512 max_rec_len ; maximum recording length | |
513 min_scan_time ; minimum scan line time | |
514 } | |
515 | |
516 | |
517 | |
518 COMP cap1_rcv "Extended facsimile capabilities 1 receiver" | |
519 { | |
520 .0 ; reserved bit | |
521 uncomp_mode ; uncompressed mode | |
522 err_corr_mode ; error correction mode | |
523 .000 ; reserved bits | |
524 t6_coding ; T.6 coding | |
525 } | |
526 | |
527 | |
528 | |
529 COMP cap2_rcv "Extended facsimile capabilities 2 receiver" | |
530 { | |
531 .0000000 ; reserved bits | |
532 } | |
533 | |
534 | |
535 | |
536 COMP cap3_rcv "Extended facsimile capabilities 3 receiver" | |
537 { | |
538 R8_lines ; R8 x 15.4 lines/mm | |
539 r_300_pels ; Res 300 x 300 pels/25.4 mm | |
540 R16_lines_pels ; R16 x 15.4 lines/mm and/or 400 x 400 pels/25.4 mm | |
541 i_res_pref ; inch-based resolution preferred | |
542 m_res_pref ; metric-based resolution preferred | |
543 min_scan_time_hr ; minimum scan line time for higher resolutions | |
544 sel_polling ; selective polling | |
545 } | |
546 | |
547 | |
548 | |
549 COMP cap4_rcv "Extended facsimile capabilities 4 receiver" | |
550 { | |
551 subaddr ; subaddressing | |
552 password ; password flag | |
553 ready_tx_doc ; ready to transmit a data file (polling) | |
554 .0 ; reserved bit | |
555 bft ; Binary File Transfer (BFT) | |
556 dtm ; Document Transfer Mode (DTM) | |
557 edi ; Electronic Data Interchange (EDI) | |
558 } | |
559 | |
560 | |
561 | |
562 COMP cap5_rcv "Extended facsimile capabilities 5 receiver" | |
563 { | |
564 btm ; Basic Transfer Mode (BTM) | |
565 .0 ; reserved bit | |
566 ready_tx_mixed ; ready to transmit a character or mixed mode document (polling) | |
567 char_mode ; character mode | |
568 .0 ; reserved bit | |
569 mixed_mode ; mixed mode (Annex E/T.4) | |
570 .0 ; reserved bit | |
571 } | |
572 | |
573 | |
574 | |
575 COMP cap6_rcv "Extended facsimile capabilities 6 receiver" | |
576 { | |
577 proc_mode_26 ; processable mode 26 | |
578 dig_network_cap ; digital network capability | |
579 duplex ; duplex and half duplex capabilities | |
580 jpeg ; JPEG coding | |
581 full_colour ; full colour mode | |
582 .0 ; reserved bit | |
583 r_12_bits_pel_comp ; Digitise 12 bits/pel component | |
584 } | |
585 | |
586 | |
587 | |
588 COMP cap7_rcv "Extended facsimile capabilities 7 receiver" | |
589 { | |
590 no_subsamp ; no subsampling | |
591 cust_illum ; custom illuminant | |
592 cust_gamut ; custom gamut range | |
593 na_letter ; North American Letter (215.9 x 279.4 mm) | |
594 na_legal ; North American Legal (215.9 x 355.6 mm) | |
595 sing_prog_seq_coding_basic ; single-progression sequential coding basic | |
596 sing_prog_seq_coding_L0 ; single-progression sequential coding optional L0 | |
597 } | |
598 | |
599 | |
600 | |
601 COMP cap0_snd "Basic facsimile capabilities sender" | |
602 { | |
603 .000000000 ; reserved bits | |
604 rec_fax_op ; receiver fax operation | |
605 data_sig_rate ; data signalling rate | |
606 R8_lines_pels ; R8 x 7.7 lines/mm and/or 200 x 200 pels/25.4 mm | |
607 two_dim_coding ; two-dimensional coding | |
608 rec_width ; recording-width | |
609 max_rec_len ; maximum recording length | |
610 min_scan_time ; minimum scan line time | |
611 } | |
612 | |
613 | |
614 | |
615 COMP cap1_snd "Extended facsimile capabilities 1 sender" | |
616 { | |
617 .0 ; reserved bit | |
618 uncomp_mode ; uncompressed mode | |
619 err_corr_mode ; error correction mode | |
620 frame_size ; frame size | |
621 .00 ; reserved bits | |
622 t6_coding ; T.6 coding | |
623 } | |
624 | |
625 | |
626 | |
627 COMP cap2_snd "Extended facsimile capabilities 2 sender" | |
628 { | |
629 .0000000 ; reserved bits | |
630 } | |
631 | |
632 | |
633 | |
634 COMP cap3_snd "Extended facsimile capabilities 3 sender" | |
635 { | |
636 R8_lines ; R8 x 15.4 lines/mm | |
637 r_300_pels ; Res 300 x 300 pels/25.4 mm | |
638 R16_lines_pels ; R16 x 15.4 lines/mm and/or 400 x 400 pels/25.4 mm | |
639 resolution_type ; resolution type selection | |
640 .000 ; reserved bits | |
641 } | |
642 | |
643 | |
644 | |
645 COMP cap4_snd "Extended facsimile capabilities 4 sender" | |
646 { | |
647 subaddr ; subaddressing | |
648 password ; password flag | |
649 .00 ; reserved bits | |
650 bft ; Binary File Transfer (BFT) | |
651 dtm ; Document Transfer Mode (DTM) | |
652 edi ; Electronic Data Interchange (EDI) | |
653 } | |
654 | |
655 | |
656 | |
657 COMP cap5_snd "Extended facsimile capabilities 5 sender" | |
658 { | |
659 btm ; Basic Transfer Mode (BTM) | |
660 .00 ; reserved bit | |
661 char_mode ; character mode | |
662 .0 ; reserved bit | |
663 mixed_mode ; mixed mode (Annex E/T.4) | |
664 .0 ; reserved bit | |
665 } | |
666 | |
667 | |
668 | |
669 COMP cap6_snd "Extended facsimile capabilities 6 sender" | |
670 { | |
671 proc_mode_26 ; processable mode 26 | |
672 dig_network_cap ; digital network capability | |
673 duplex ; duplex and half duplex capabilities | |
674 jpeg ; JPEG coding | |
675 full_colour ; full colour mode | |
676 huffman_tables ; preferred Huffman tables | |
677 r_12_bits_pel_comp ; Digitise 12 bits/pel component | |
678 } | |
679 | |
680 | |
681 | |
682 COMP cap7_snd "Extended facsimile capabilities 7 sender" | |
683 { | |
684 no_subsamp ; no subsampling | |
685 cust_illum ; custom illuminant | |
686 cust_gamut ; custom gamut range | |
687 na_letter ; North American Letter (215.9 x 279.4 mm) | |
688 na_legal ; North American Legal (215.9 x 355.6 mm) | |
689 sing_prog_seq_coding_basic ; single-progression sequential coding basic | |
690 sing_prog_seq_coding_L0 ; single-progression sequential coding optional L0 | |
691 } | |
692 | |
693 | |
694 | |
695 | |
696 | |
697 | |
698 MSG BCS_DIS both 0b00000001 ; BCS Digital identification signal | |
699 { | |
700 fcf ; Facsimile control field | |
701 cap0_rcv ; basic facsimile capabilities receiver | |
702 ! cap1_rcv ; extended facsimile capabilities 1 receiver | |
703 ! cap2_rcv ; extended facsimile capabilities 2 receiver | |
704 ! cap3_rcv ; extended facsimile capabilities 3 receiver | |
705 ! cap4_rcv ; extended facsimile capabilities 4 receiver | |
706 ! cap5_rcv ; extended facsimile capabilities 5 receiver | |
707 ! cap6_rcv ; extended facsimile capabilities 6 receiver | |
708 # cap7_rcv ; extended facsimile capabilities 7 receiver | |
709 } | |
710 | |
711 | |
712 | |
713 MSG BCS_CSI both 0b00000010 ; BCS Called subscriber identification | |
714 { | |
715 fcf ; Facsimile control field | |
716 T30_IDENT cld_sub_nr [0..20] ; called subscriber number | |
717 } | |
718 | |
719 | |
720 | |
721 MSG BCS_NSF both 0b00000100 ; BCS Non standard facilities | |
722 { | |
723 fcf ; Facsimile control field | |
724 non_std_fac [.MAX_NSF_LEN] ; Non standard facilities | |
725 } | |
726 | |
727 | |
728 | |
729 MSG BCS_DTC both 0b10000001 ; BCS Digital transmit command | |
730 { | |
731 fcf ; Facsimile control field | |
732 cap0_rcv ; basic facsimile capabilities receiver | |
733 ! cap1_rcv ; extended facsimile capabilities 1 receiver | |
734 ! cap2_rcv ; extended facsimile capabilities 2 receiver | |
735 ! cap3_rcv ; extended facsimile capabilities 3 receiver | |
736 ! cap4_rcv ; extended facsimile capabilities 4 receiver | |
737 ! cap5_rcv ; extended facsimile capabilities 5 receiver | |
738 ! cap6_rcv ; extended facsimile capabilities 6 receiver | |
739 # cap7_rcv ; extended facsimile capabilities 7 receiver | |
740 } | |
741 | |
742 | |
743 | |
744 MSG BCS_CIG both 0b10000010 ; BCS Called subscriber identification | |
745 { | |
746 fcf ; Facsimile control field | |
747 T30_IDENT clg_sub_nr [0..20] ; calling subscriber number | |
748 } | |
749 | |
750 | |
751 | |
752 MSG BCS_NSC both 0b10000100 ; BCS Non standard facilities command | |
753 { | |
754 fcf ; Facsimile control field | |
755 non_std_fac [.MAX_NSF_LEN] ; Non standard facilities | |
756 } | |
757 | |
758 | |
759 | |
760 MSG BCS_PWD_POLL both 0b10000011 ; BCS password send | |
761 { | |
762 fcf ; Facsimile control field | |
763 T30_IDENT pm_pword [0..20] ; Password for polling | |
764 } | |
765 | |
766 | |
767 | |
768 MSG BCS_SEP both 0b10000101 ; BCS Selective polling | |
769 { | |
770 fcf ; Facsimile control field | |
771 T30_IDENT pm_sub_addr [0..20] ; Sub address | |
772 } | |
773 | |
774 | |
775 | |
776 MSG BCS_DCS both 0b01000001 ; BCS Digital command signal | |
777 { | |
778 fcf ; Facsimile control field | |
779 cap0_snd ; basic facsimile capabilities sender | |
780 ! cap1_snd ; extended facsimile capabilities 1 sender | |
781 ! cap2_snd ; extended facsimile capabilities 2 sender | |
782 ! cap3_snd ; extended facsimile capabilities 3 sender | |
783 ! cap4_snd ; extended facsimile capabilities 4 sender | |
784 ! cap5_snd ; extended facsimile capabilities 5 sender | |
785 ! cap6_snd ; extended facsimile capabilities 6 sender | |
786 # cap7_snd ; extended facsimile capabilities 7 sender | |
787 } | |
788 | |
789 | |
790 | |
791 MSG BCS_TSI both 0b01000010 ; BCS Transmitting Subscriber Identification | |
792 { | |
793 fcf ; Facsimile control field | |
794 T30_IDENT tra_sub_nr [0..20] ; transmitter subscriber number | |
795 } | |
796 | |
797 | |
798 | |
799 MSG BCS_NSS both 0b01000100 ; BCS Non standard facilities set up | |
800 { | |
801 fcf ; Facsimile control field | |
802 non_std_fac [.MAX_NSF_LEN] ; Non standard facilities | |
803 } | |
804 | |
805 | |
806 | |
807 MSG BCS_SUB both 0b01000011 ; BCS Sub address | |
808 { | |
809 fcf ; Facsimile control field | |
810 T30_IDENT sub_addr [0..20] ; Sub address | |
811 } | |
812 | |
813 | |
814 | |
815 MSG BCS_PWD_SND both 0b01000101 ; BCS password receive | |
816 { | |
817 GSM3_V fcf ; Facsimile control field | |
818 T30_IDENT sm_pword [0..20] ; Password for sending | |
819 } | |
820 | |
821 | |
822 | |
823 MSG BCS_CFR both 0b00100001 ; BCS Confirmation to receive | |
824 { | |
825 fcf ; Facsimile control field | |
826 } | |
827 | |
828 | |
829 | |
830 MSG BCS_FTT both 0b00100010 ; BCS Failure to train | |
831 { | |
832 fcf ; Facsimile control field | |
833 } | |
834 | |
835 | |
836 | |
837 MSG BCS_EOM both 0b01110001 ; BCS End of message | |
838 { | |
839 fcf ; Facsimile control field | |
840 } | |
841 | |
842 | |
843 | |
844 MSG BCS_MPS both 0b01110010 ; BCS Multiple page signal | |
845 { | |
846 fcf ; Facsimile control field | |
847 } | |
848 | |
849 | |
850 | |
851 MSG BCS_EOP both 0b01110100 ; BCS End of procedure | |
852 { | |
853 fcf ; Facsimile control field | |
854 } | |
855 | |
856 | |
857 | |
858 MSG BCS_PRI_EOM both 0b01111001 ; BCS Procedure interrupt EOM | |
859 { | |
860 GSM3_V fcf ; Facsimile control field | |
861 } | |
862 | |
863 | |
864 | |
865 MSG BCS_PRI_MPS both 0b01111010 ; BCS Procedure interrupt MPS | |
866 { | |
867 fcf ; Facsimile control field | |
868 } | |
869 | |
870 | |
871 | |
872 MSG BCS_PRI_EOP both 0b01111100 ; BCS Procedure interrupt EOP | |
873 { | |
874 fcf ; Facsimile control field | |
875 } | |
876 | |
877 | |
878 | |
879 MSG BCS_MCF both 0b00110001 ; BCS Message confirmation | |
880 { | |
881 fcf ; Facsimile control field | |
882 } | |
883 | |
884 | |
885 | |
886 MSG BCS_RTP both 0b00110011 ; BCS Retrain positive | |
887 { | |
888 fcf ; Facsimile control field | |
889 } | |
890 | |
891 | |
892 | |
893 MSG BCS_RTN both 0b00110010 ; BCS Retrain negative | |
894 { | |
895 fcf ; Facsimile control field | |
896 } | |
897 | |
898 | |
899 | |
900 MSG BCS_PIP both 0b00110101 ; BCS Procedure interrupt positive | |
901 { | |
902 fcf ; Facsimile control field | |
903 } | |
904 | |
905 | |
906 | |
907 MSG BCS_PIN both 0b00110100 ; BCS Procedure interrupt negative | |
908 { | |
909 fcf ; Facsimile control field | |
910 } | |
911 | |
912 | |
913 | |
914 MSG BCS_DCN both 0b01011111 ; BCS Disconnect | |
915 { | |
916 fcf ; Facsimile control field | |
917 } | |