diff src/cs/drivers/drv_app/pwr/pwr_disch.c @ 0:b6a5e36de839

src/cs: initial import from Magnetite
author Mychaela Falconia <falcon@freecalypso.org>
date Sun, 15 Jul 2018 04:39:26 +0000
parents
children
line wrap: on
line diff
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/src/cs/drivers/drv_app/pwr/pwr_disch.c	Sun Jul 15 04:39:26 2018 +0000
@@ -0,0 +1,149 @@
+/*******************************************************************************
+ *
+ * pwr_disch.c
+ *
+ * Purpose: This file contains functions for battery discharge management.
+ *
+ * (C) Texas Instruments 2001
+ *
+ ******************************************************************************/
+
+#include "rv/rv_defined_swe.h"	   // for RVM_PWR_SWE
+
+#ifdef RVM_PWR_SWE
+
+#include "abb/abb.h"
+#include "rvm/rvm_use_id_list.h"
+#include "pwr/pwr_disch.h"
+#include "power/power.h"
+#include "spi/spi_task.h"
+#include "pwr/pwr_cust.h"
+#include "pwr/pwr_messages.h"
+#include "spi/spi_env.h"
+#include "pwr/pwr_env.h"
+
+/* Define a pointer to the PWR Environment control block.  */
+extern T_PWR_ENV_CTRL_BLK *pwr_env_ctrl_blk;
+
+
+
+
+/*******************************************************************************
+** Function         pwr_discharge_timer_process
+**
+** Description      
+**
+*******************************************************************************/
+void pwr_discharge_timer_process(void)
+{
+   rvf_send_trace("TIMER3", 6, NULL_PARAM, RV_TRACE_LEVEL_DEBUG_LOW, PWR_USE_ID);
+   if (SPI_GBL_INFO_PTR->is_gsm_on == TRUE)
+   {
+      pwr_handle_discharge(); /* battery discharge management */
+   } 
+
+}
+
+
+
+/*******************************************************************************
+** Function         pwr_handle_discharge
+**
+** Description      Compares the battery voltage with some thresholds and, if a 
+**                  threshold is passed, sends event(s) to the upper layer.
+**                  Re-start the timer with a value depending on the discharge 
+**                  level.
+**
+*******************************************************************************/
+void pwr_handle_discharge(void)
+{
+   UINT16 timer_value;
+   UINT16 status;
+   UINT16 bat_madc_voltage, bat_voltage;
+   static T_PWR_PERCENT remain_capacity = 100;  /* since this variable is declared as static */
+                                                /* it will keep its value from one function call to the other */
+   T_PWR_PERCENT current_capacity;
+  
+   if (SPI_GBL_INFO_PTR->is_adc_on == FALSE) 
+   {
+      /* Start VBAT channel conversion by writing in the result register */
+      ABB_Write_Register_on_page(PAGE0, VBATREG, 0x0000);
+      rvf_delay(RVF_MS_TO_TICKS(5));
+      bat_madc_voltage = ABB_Read_Register_on_page(PAGE0, VBATREG);
+      rvf_send_trace("battery voltage (MADC code) ", 28, bat_madc_voltage, RV_TRACE_LEVEL_DEBUG_LOW, PWR_USE_ID);
+   }
+   else /* The L1 asks for ADC conversions */
+   {
+#ifndef _WINDOWS
+      bat_madc_voltage = SPI_GBL_INFO_PTR->adc_result[0];
+#else
+      bat_madc_voltage = ABB_Read_Register_on_page(PAGE0, VBATREG);
+#endif
+   }
+
+   /* Find the remaining capacity in the battery corresponding to this new voltage */
+   bat_voltage = pwr_adc_to_mvolt(bat_madc_voltage);
+   rvf_send_trace("battery voltage (mV) ", 21, bat_voltage, RV_TRACE_LEVEL_DEBUG_LOW, PWR_USE_ID);
+   current_capacity = pwr_get_capacity_vs_voltage(bat_voltage);
+   rvf_send_trace("current capacity (%) ", 21, current_capacity, RV_TRACE_LEVEL_DEBUG_LOW, PWR_USE_ID);
+
+   status = ABB_Read_Status();
+
+   /* Determine if a threshold has been passed */
+   if (current_capacity != remain_capacity) 
+   {
+      /* a new threshold has been passed */
+      remain_capacity = current_capacity;
+
+      /* informs the upper layer */
+      pwr_send_bat_discharge_event(remain_capacity);
+
+      if (status & CHGPRES)   /* charger plugged */
+      {
+         if (remain_capacity == CHARGE_START_AGAIN_CAPACITY)
+         {
+            PWR_Charger_Plug();
+         }
+      }
+
+      else  /* charger not plugged */
+      {
+         if(remain_capacity <= pwr_env_ctrl_blk->power_alert.remain_capa_threshold)
+         {
+            /* informs the upper layer that the battery is low */
+            pwr_send_low_bat_event(remain_capacity);
+            timer_value = SPI_TIMER3_INTERVAL_BIS; /* 10 s */
+         }
+         else  
+         {
+#ifndef _WINDOWS
+            timer_value = SPI_TIMER3_INTERVAL; /* 1 minute */
+#else
+            timer_value = SPI_TIMER3_INTERVAL_BIS; /* 10 s */
+#endif
+         }
+
+         /* Start timer with a value depending on the remaining capacity in the battery */
+         rvf_start_timer (SPI_TIMER3,
+                          RVF_MS_TO_TICKS (timer_value),
+                          FALSE);
+      }
+   }
+
+   else /* the capacity has not changed */
+   {
+#ifndef _WINDOWS
+      timer_value = SPI_TIMER3_INTERVAL; /* 1 minute */
+#else
+      timer_value = SPI_TIMER3_INTERVAL_BIS; /* 10 s */
+#endif
+
+      /* Start timer with a value depending on the remaining capacity in the battery */
+      rvf_start_timer (SPI_TIMER3,
+                       RVF_MS_TO_TICKS (timer_value),
+                       FALSE);
+
+   }
+}
+
+#endif /* #ifdef RVM_PWR_SWE */