comparison doc/Sniffing-hw-setup @ 51:8a3003860cf8

doc/Sniffing-hw-setup: wire assignments for mv-sniffer setup
author Mychaela Falconia <falcon@freecalypso.org>
date Sun, 24 Sep 2023 01:15:44 +0000
parents 1068f9fd41d5
children 95ed46b5f8f1
comparison
equal deleted inserted replaced
50:f8c27c2bde0e 51:8a3003860cf8
52 still need to get it assembled, which will require at least one trip to 52 still need to get it assembled, which will require at least one trip to
53 Technotronix, or maybe even two trips. Once we have this board assembled, we 53 Technotronix, or maybe even two trips. Once we have this board assembled, we
54 should have a working SIM sniffing path that is fully compatible with all 3 54 should have a working SIM sniffing path that is fully compatible with all 3
55 voltage classes, per the original intent of FC SIMsniff project. 55 voltage classes, per the original intent of FC SIMsniff project.
56 56
57 Wire assignments for this HW setup
58 ----------------------------------
59
60 A 6-wire ribbon cable, cut from a standard multicolor ribbon cable spool and
61 outfitted with custom crimped connectors, will be used to make the connection
62 between sim-fpc-pasv and mv-sniffer boards. Wire color assignments in this
63 ad hoc connection cable are:
64
65 Wire SIM interface pin
66 ---------------------------------
67 brown VCC
68 red RST
69 orange CLK
70 yellow GND
71 green GND
72 blue I/O
73
57 HW setup version 2 74 HW setup version 2
58 ================== 75 ==================
59 76
60 (a little more distant, but will be needed before wider spread) 77 (a little more distant, but will be needed before wider spread)