view cdg-hybrid/sap/mnlc.pdf @ 51:04aaa5622fa7

disable deep sleep when Iota LEDB is on TI's Iota chip docs say that CLK13M must be running in order for LEDB to work, and practical experience on Mot C139 which uses Iota LEDB for its keypad backlight concurs: if Calypso enters deep sleep while the keypad backlight is turned on, the light flickers visibly as the chipset goes into and out of deep sleep. TI's original L1 sleep manager code had logic to disable deep sleep when LT_Status() returns nonzero, but that function only works for B-Sample and C-Sample LT, always returns 0 on BOARD 41 - no check of Iota LEDB status anywhere. Change this code for our current hardware: disable deep sleep when Iota LEDB has been turned on through LLS.
author Mychaela Falconia <falcon@freecalypso.org>
date Mon, 19 Oct 2020 05:11:29 +0000
parents 35f7a1dc9f7d
children
line wrap: on
line source

;********************************************************************************
;*** File           : mnlc.pdf
;*** Creation       : Wed Mar 11 09:58:25 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : mnlc
;*** Document No.   : 8443.104.02.003
;*** Document Date  : 2002-10-25
;*** Document Status: SUBMITTED
;*** Document Author: TML
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:48:12 2007"
PRAGMA 	LAST_MODIFIED 	"2002-10-25"
PRAGMA 	ID_AND_VERSION 	"8443.104.02.003"



CONST 	L_MAX_CALLED_BCD_NO_LENGTH 	10 	; Max Bcd number length (digits)
CONST 	CURSOR_SMS_TEXT_140 	140 	; Position SMS Message



VALTAB 	VAL_data_valid
VAL 	0 	DATA_VALID 	""
VAL 	1 	DATA_INVALID 	""




VAR 	reference 	"Reference" 	S


VAR 	bcd 	"Bcd Number" 	B


VAR 	data_valid 	"Cursor Data Valid" 	B

VAL 	@p_mnlc - VAL_data_valid@ 	

VAR 	number_length 	"Number of decimal digits in the Bcd number" 	B


VAR 	sms_text 	"SMS text" 	B





COMP 	called_party_bcd_num 	 "called Party Bcd number"
{
 	number_length 	 ; Number Length
 	bcd 	[L_MAX_CALLED_BCD_NO_LENGTH] 	 ; Bcd Number
}






; MNLC_SMS_MEAS_REQ 	0x80000044
; MNLC_SMS_MEAS_CNF 	0x80004044



PRIM 	MNLC_SMS_MEAS_REQ 	0x80000044
{
 	reference 	 ; Reference SMS request
 	called_party_bcd_num 	 ; Called Bcd Number
}






PRIM 	MNLC_SMS_MEAS_CNF 	0x80004044
{
 	reference 	 ; Reference SMS request
 	data_valid 	 ; Cursor Data Valid
 	sms_text 	[CURSOR_SMS_TEXT_140] 	 ; Cursor SMS
}