enable L1_NEW_AEC in l1_confg.h (bold change)
The AEC function implemented in DSP ROM 3606 on the Calypso silicon
we work with is the one that corresponds to L1_NEW_AEC; the same holds
for DSP 34 and even for DSP 33 with more recent patch versions.
However, TI shipped their TCS211 reference fw with L1_NEW_AEC set to 0,
thus driving AEC the old way if anyone tried to enable it, either via
AT%Nxxxx or via the audio mode facility. As a result, the fw would
try to control features which no longer exist in the DSP (long vs short
echo and the old echo suppression level bits), while providing no way
to tune the 8 new parameter words added to the DSP's NDB page.
The only sensible solution is to bite the bullet and enable L1_NEW_AEC
in L1 config, with fallout propagating into RiViera Audio Service
T_AUDIO_AEC_CFG structure and into /aud/*.cfg binary file format.
The latter fallout will be addressed in further code changes.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Thu, 29 Jul 2021 18:32:40 +0000 |
parents | 4e78acac3d88 |
children |
line wrap: on
line source
/******************************************************************************* * * pwr_api.c * * Purpose: This file contains functions that can be accessed by any SWE * to use power management services. * * Author Candice Bazanegue (c-brille@ti.com) * * * (C) Texas Instruments 2001 * ******************************************************************************/ #include "rv/rv_defined_swe.h" // for RVM_PWR_SWE #ifdef RVM_PWR_SWE #include "rvm/rvm_use_id_list.h" #include "spi/spi_api.h" #include "spi/spi_env.h" #include "pwr/pwr_env.h" #include "pwr/pwr_cust.h" #include "pwr/pwr_messages.h" #include "pwr/pwr_messages_i.h" /* Define a pointer to the PWR Environment control block. */ extern T_PWR_ENV_CTRL_BLK *pwr_env_ctrl_blk; /******************************************************************************* ** ** Function power_info_register ** ** Description Function called by the MMI to enable (or disable) the receipt ** of several events related to the charging process or the ** discharge levels. ** ** *******************************************************************************/ T_POWER_RET power_info_register(BOOLEAN info_enable, T_RV_RETURN return_path) { if (((pwr_env_ctrl_blk->power_info.return_path.callback_func)!= NULL) || (pwr_env_ctrl_blk->power_info.return_path.addr_id != RVF_INVALID_ADDR_ID)) { rvf_send_trace("power_info_register : info already registered, performs another registration", 76, NULL_PARAM, RV_TRACE_LEVEL_DEBUG_HIGH, PWR_USE_ID); } pwr_env_ctrl_blk->power_info.info_enable = info_enable; pwr_env_ctrl_blk->power_info.return_path.addr_id = return_path.addr_id; pwr_env_ctrl_blk->power_info.return_path.callback_func = return_path.callback_func; return (POWER_OK); } /******************************************************************************* ** ** Function power_alert_register ** ** Description Function called by the MMI to configure the threshold of ** remaining energy in the battery, under which the MMI will ** receive low battery alerts. ** ** *******************************************************************************/ T_POWER_RET power_alert_register(T_PWR_PERCENT remain_capa_threshold, T_RV_RETURN return_path) { if (((pwr_env_ctrl_blk->power_alert.return_path.callback_func)!= NULL) || (pwr_env_ctrl_blk->power_alert.return_path.addr_id != RVF_INVALID_ADDR_ID)) { rvf_send_trace("power_alert_register : info already registered, performs another registration", 77, NULL_PARAM, RV_TRACE_LEVEL_DEBUG_HIGH, PWR_USE_ID); } pwr_env_ctrl_blk->power_alert.remain_capa_threshold = remain_capa_threshold; pwr_env_ctrl_blk->power_alert.return_path.addr_id = return_path.addr_id; pwr_env_ctrl_blk->power_alert.return_path.callback_func = return_path.callback_func; return (POWER_OK); } /******************************************************************************* ** ** Function power_emergency_register ** ** Description Function called by the MMI to define the call-back function ** which will be called in case of emergency switch OFF. ** ** *******************************************************************************/ T_POWER_RET power_emergency_register(T_RV_RETURN return_path) { if (((pwr_env_ctrl_blk->power_emergency.callback_func)!= NULL) || (pwr_env_ctrl_blk->power_emergency.addr_id != RVF_INVALID_ADDR_ID)) { rvf_send_trace("power_emergency_register : info already registered, performs another registration", 80, NULL_PARAM, RV_TRACE_LEVEL_DEBUG_HIGH, PWR_USE_ID); } pwr_env_ctrl_blk->power_emergency.addr_id = return_path.addr_id; pwr_env_ctrl_blk->power_emergency.callback_func = return_path.callback_func; return (POWER_OK); } /******************************************************************************* ** ** Function pwr_callback_func ** ** Description ** ** ** *******************************************************************************/ void pwr_callback_func(void *ptr) { T_PWR_CHARGING_STATE charge_started; /* Charge started? */ charge_started = pwr_env_ctrl_blk->charging_state; if (charge_started == CHARGE_STOPPED) { /* Ask for battery temperature measurement */ pwr_get_battery_temperature(); } else if ((charge_started == CI_CHARGE_STARTED) || (charge_started == CV_CHARGE_STARTED)) { /* The battery temperature has been measured during the charge */ pwr_get_bat_info(); } } /******************************************************************************* ** ** Function pwr_get_bat_info ** ** Description ** ** *******************************************************************************/ void pwr_get_bat_info(void) { UINT16 bat_voltage, bat_madc_voltage; UINT16 charger_current, bat_madc_current; UINT16 status; BOOLEAN charger_plugged; T_PWR_CHARGING_STATE charge_started; T_PWR_PERCENT remain_capacity; INT16 bat_temperature; /* Voltage and current */ /* Read the conversion results in the analog device registers */ bat_madc_voltage = ABB_Read_Register_on_page(PAGE0, VBATREG); bat_madc_current = ABB_Read_Register_on_page(PAGE0, ICHGREG); bat_voltage = pwr_adc_to_mvolt(bat_madc_voltage); charger_current = pwr_adc_to_mA(bat_madc_current); /* Remaining capacity in the battery */ remain_capacity = pwr_get_capacity_vs_voltage(bat_voltage); /* Charger plugged? */ status = ABB_Read_Status(); if (status & CHGPRES) { charger_plugged = TRUE; } else { charger_plugged = FALSE; } /* Charge started? */ charge_started = pwr_env_ctrl_blk->charging_state; /* The battery temperature is already measured during the charge */ /* Use the last result */ bat_temperature = pwr_env_ctrl_blk->bat_celsius_temp; /* Send the results to the upper layer */ pwr_send_battery_info(bat_voltage, bat_temperature, charger_current, charger_plugged, charge_started, remain_capacity); } /******************************************************************************* ** ** Function power_battery_information ** ** Description Function called by the MMI to get information concerning ** the battery. ** ** *******************************************************************************/ T_POWER_RET power_battery_information(void) { T_RV_RET spi_return; spi_return = pwr_spi_battery_info(pwr_callback_func); if (spi_return != RV_OK) { return (POWER_ERROR); } return (POWER_OK); } #endif /* #ifdef RVM_PWR_SWE */