FreeCalypso > hg > fc-tourmaline
view src/cs/drivers/drv_app/pwr/pwr_api.c @ 223:740a8e8fc9d7
startup sync logic rework for the new PWON button boot scheme
Previously we added logic to the MMI task to hold off PEI init until
R2D is running, and then extended that condition to wait for FCHG
init too. However, the dependencies of MMI upon R2D and FCHG don't
start until mmiInit(), and that call is driven by Switch_ON() code,
hence the wait for R2D and FCHG init can be made in that code path
instead of the MMI task. Furthermore, with our new way of signaling
PWON button boot to MMI, we need a new wait to ensure that the MMI
task is up - previously this assurance was provided by the wait for
Kp pointers to be set.
Solution: revert our previous PEI init hold-off additions to MMI,
add a new flag indicating MMI task init done, and put the combined
wait for all needed conditions into our new PWON button boot code
in power.c.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Tue, 27 Apr 2021 06:24:52 +0000 |
parents | 4e78acac3d88 |
children |
line wrap: on
line source
/******************************************************************************* * * pwr_api.c * * Purpose: This file contains functions that can be accessed by any SWE * to use power management services. * * Author Candice Bazanegue (c-brille@ti.com) * * * (C) Texas Instruments 2001 * ******************************************************************************/ #include "rv/rv_defined_swe.h" // for RVM_PWR_SWE #ifdef RVM_PWR_SWE #include "rvm/rvm_use_id_list.h" #include "spi/spi_api.h" #include "spi/spi_env.h" #include "pwr/pwr_env.h" #include "pwr/pwr_cust.h" #include "pwr/pwr_messages.h" #include "pwr/pwr_messages_i.h" /* Define a pointer to the PWR Environment control block. */ extern T_PWR_ENV_CTRL_BLK *pwr_env_ctrl_blk; /******************************************************************************* ** ** Function power_info_register ** ** Description Function called by the MMI to enable (or disable) the receipt ** of several events related to the charging process or the ** discharge levels. ** ** *******************************************************************************/ T_POWER_RET power_info_register(BOOLEAN info_enable, T_RV_RETURN return_path) { if (((pwr_env_ctrl_blk->power_info.return_path.callback_func)!= NULL) || (pwr_env_ctrl_blk->power_info.return_path.addr_id != RVF_INVALID_ADDR_ID)) { rvf_send_trace("power_info_register : info already registered, performs another registration", 76, NULL_PARAM, RV_TRACE_LEVEL_DEBUG_HIGH, PWR_USE_ID); } pwr_env_ctrl_blk->power_info.info_enable = info_enable; pwr_env_ctrl_blk->power_info.return_path.addr_id = return_path.addr_id; pwr_env_ctrl_blk->power_info.return_path.callback_func = return_path.callback_func; return (POWER_OK); } /******************************************************************************* ** ** Function power_alert_register ** ** Description Function called by the MMI to configure the threshold of ** remaining energy in the battery, under which the MMI will ** receive low battery alerts. ** ** *******************************************************************************/ T_POWER_RET power_alert_register(T_PWR_PERCENT remain_capa_threshold, T_RV_RETURN return_path) { if (((pwr_env_ctrl_blk->power_alert.return_path.callback_func)!= NULL) || (pwr_env_ctrl_blk->power_alert.return_path.addr_id != RVF_INVALID_ADDR_ID)) { rvf_send_trace("power_alert_register : info already registered, performs another registration", 77, NULL_PARAM, RV_TRACE_LEVEL_DEBUG_HIGH, PWR_USE_ID); } pwr_env_ctrl_blk->power_alert.remain_capa_threshold = remain_capa_threshold; pwr_env_ctrl_blk->power_alert.return_path.addr_id = return_path.addr_id; pwr_env_ctrl_blk->power_alert.return_path.callback_func = return_path.callback_func; return (POWER_OK); } /******************************************************************************* ** ** Function power_emergency_register ** ** Description Function called by the MMI to define the call-back function ** which will be called in case of emergency switch OFF. ** ** *******************************************************************************/ T_POWER_RET power_emergency_register(T_RV_RETURN return_path) { if (((pwr_env_ctrl_blk->power_emergency.callback_func)!= NULL) || (pwr_env_ctrl_blk->power_emergency.addr_id != RVF_INVALID_ADDR_ID)) { rvf_send_trace("power_emergency_register : info already registered, performs another registration", 80, NULL_PARAM, RV_TRACE_LEVEL_DEBUG_HIGH, PWR_USE_ID); } pwr_env_ctrl_blk->power_emergency.addr_id = return_path.addr_id; pwr_env_ctrl_blk->power_emergency.callback_func = return_path.callback_func; return (POWER_OK); } /******************************************************************************* ** ** Function pwr_callback_func ** ** Description ** ** ** *******************************************************************************/ void pwr_callback_func(void *ptr) { T_PWR_CHARGING_STATE charge_started; /* Charge started? */ charge_started = pwr_env_ctrl_blk->charging_state; if (charge_started == CHARGE_STOPPED) { /* Ask for battery temperature measurement */ pwr_get_battery_temperature(); } else if ((charge_started == CI_CHARGE_STARTED) || (charge_started == CV_CHARGE_STARTED)) { /* The battery temperature has been measured during the charge */ pwr_get_bat_info(); } } /******************************************************************************* ** ** Function pwr_get_bat_info ** ** Description ** ** *******************************************************************************/ void pwr_get_bat_info(void) { UINT16 bat_voltage, bat_madc_voltage; UINT16 charger_current, bat_madc_current; UINT16 status; BOOLEAN charger_plugged; T_PWR_CHARGING_STATE charge_started; T_PWR_PERCENT remain_capacity; INT16 bat_temperature; /* Voltage and current */ /* Read the conversion results in the analog device registers */ bat_madc_voltage = ABB_Read_Register_on_page(PAGE0, VBATREG); bat_madc_current = ABB_Read_Register_on_page(PAGE0, ICHGREG); bat_voltage = pwr_adc_to_mvolt(bat_madc_voltage); charger_current = pwr_adc_to_mA(bat_madc_current); /* Remaining capacity in the battery */ remain_capacity = pwr_get_capacity_vs_voltage(bat_voltage); /* Charger plugged? */ status = ABB_Read_Status(); if (status & CHGPRES) { charger_plugged = TRUE; } else { charger_plugged = FALSE; } /* Charge started? */ charge_started = pwr_env_ctrl_blk->charging_state; /* The battery temperature is already measured during the charge */ /* Use the last result */ bat_temperature = pwr_env_ctrl_blk->bat_celsius_temp; /* Send the results to the upper layer */ pwr_send_battery_info(bat_voltage, bat_temperature, charger_current, charger_plugged, charge_started, remain_capacity); } /******************************************************************************* ** ** Function power_battery_information ** ** Description Function called by the MMI to get information concerning ** the battery. ** ** *******************************************************************************/ T_POWER_RET power_battery_information(void) { T_RV_RET spi_return; spi_return = pwr_spi_battery_info(pwr_callback_func); if (spi_return != RV_OK) { return (POWER_ERROR); } return (POWER_OK); } #endif /* #ifdef RVM_PWR_SWE */