audio mode load: gracefully handle mode files of wrong AEC version Unfortunately our change of enabling L1_NEW_AEC (which is necessary in order to bring our Calypso ARM fw into match with the underlying DSP reality) brings along a change in the audio mode file binary format and file size - all those new tunable AEC parameters do need to be stored somewhere, after all. But we already have existing mode files in the old format, and setting AEC config to garbage when loading old audio modes (which is what would happen without the present change) is not an appealing proposition. The solution implemented in the present change is as follows: the audio mode loading code checks the file size, and if it differs from the active version of T_AUDIO_MODE, the T_AUDIO_AEC_CFG structure is cleared - set to the default (disabled AEC) for the compiled type of AEC. We got lucky in that this varying T_AUDIO_AEC_CFG structure sits at the end of T_AUDIO_MODE!
author Mychaela Falconia <falcon@freecalypso.org>
date Fri, 30 Jul 2021 02:55:48 +0000
parents 35f7a1dc9f7d
children
line wrap: on
line source

;********************************************************************************
;*** File           : gmmaa.pdf
;*** Creation       : Wed Mar 11 09:58:03 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : gmmaa
;*** Document No.   : 8441.107.99.001
;*** Document Date  : 1999-06-22
;*** Document Status: BEING_PROCESSED
;*** Document Author: ANS
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:41:58 2007"
PRAGMA 	LAST_MODIFIED 	"1999-06-22"
PRAGMA 	ID_AND_VERSION 	"8441.107.99.001"






VALTAB 	VAL_aa_timer
VAL 	DEF 	 	"value is incremented in multiples of 1 min"
VAL 	0 	GMMAA_TIMER_2_SEC 	"value is incremented in multiples of 2 sec"
VAL 	1 	GMMAA_TIMER_1_MIN 	"value is incremented in multiples of 1 min"
VAL 	2 	GMMAA_TIMER_1_DH 	"value is incremented in multiples of 1 decihour"
VAL 	7 	GMMAA_TIMER_DEACT 	"timer is deactivated"




VAR 	aa_timer 	"GPRS READY timer" 	B

VAL 	@p_gmmaa - VAL_aa_timer@ 	







; GMMAA_ESTABLISH_REQ 	0x2500
; GMMAA_RELEASE_IND 	0x6500
; GMMAA_ESTABLISH_REJ 	0x6501
; GMMAA_TIMER_REQ 	0x2501



PRIM 	GMMAA_ESTABLISH_REQ 	0x2500
{
}






PRIM 	GMMAA_RELEASE_IND 	0x6500
{
}






PRIM 	GMMAA_ESTABLISH_REJ 	0x6501
{
}






PRIM 	GMMAA_TIMER_REQ 	0x2501
{
 	aa_timer 	 ; GPRS AA-READY  timer
}