backlight control on Luna: switch PWL instead of LEDB This change is preliminary toward upcoming rework of backlight control logic in our UI firmware. LEDB does not exist on Tango-based platforms (it is not brought out on Tango modules), thus turning it on and off produces absolutely no effect beyond making L1 disable deep sleep when LEDB is turned on. However, both iWOW DSK and our upcoming FC Caramel2 boards have a PWL LED, so let's switch that LED on and off to indicate the state of the UI firmware's backlight control. Note that we are NOT switching the actual Luna LCD backlight here, even though it is trivially controlled with a GPIO. The reason for this seemingly strange choice is that we don't want to turn this development board LCD backlight off until we bring the higher-level backlight control logic up to par, including new logic to "swallow" the first keypress that turns on the darkened LCD.
author Mychaela Falconia <falcon@freecalypso.org>
date Sat, 24 Oct 2020 07:39:54 +0000
parents 35f7a1dc9f7d
children
line wrap: on
line source

;********************************************************************************
;*** File           : cst.pdf
;*** Creation       : Wed Mar 11 09:57:45 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : cst
;*** Document No.   : 8415.060.99.003
;*** Document Date  : 1999-09-21
;*** Document Status: BEING_PROCESSED
;*** Document Author: Heiner
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:39:04 2007"
PRAGMA 	LAST_MODIFIED 	"1999-09-21"
PRAGMA 	ID_AND_VERSION 	"8415.060.99.003"









VAR 	adc_values 	"AD conversion values" 	S


VAR 	stop_address 	"contains stop address" 	L


VAR 	error_code 	"Error code" 	B


VAR 	index 	"Index" 	B








; CST_ADC_IND 	0x5600
; CST_VM_STOP_PLAY_IND 	0x5601
; CST_VM_STOP_RECORD_IND 	0x5602
; CST_SR_IND 	0x5603



PRIM 	CST_ADC_IND 	0x5600
{
 	adc_values 	[9] 	 ; AD conversion values
}






PRIM 	CST_VM_STOP_PLAY_IND 	0x5601
{
 	stop_address 	 ; stop address
}






PRIM 	CST_VM_STOP_RECORD_IND 	0x5602
{
 	stop_address 	 ; stop address
}






PRIM 	CST_SR_IND 	0x5603
{
 	error_code 	 ; Error code