backlight rework: Condat light driver accepts levels The present change is another intermediate step on the path toward new FreeCalypso backlight handling. At this intermediate step the Condat light driver accepts 0-255 backlight levels driven by MFW, and puts them out on PWL on Luna development boards. At the same time on C139 it is now possible to turn on the display backlight with or without the keypad bl - the lsb of the 0-255 backlight level controls the keypad bl. MFW presently drives only 0 and 255 backlight levels, thus there is no visible behavioral change yet - but the plan for subsequent stages of this backlight rework is to add a dimmed backlight state (no keypad bl on C139) during active calls.
author Mychaela Falconia <falcon@freecalypso.org>
date Sat, 24 Oct 2020 20:44:04 +0000
parents fa8dc04885d8
children
line wrap: on
line source

/* 
+----------------------------------------------------------------------------- 
|  Project :  GPRS (8441)
|  Modul   :  GRLC
+----------------------------------------------------------------------------- 
|  Copyright 2002 Texas Instruments Berlin, AG 
|                 All rights reserved. 
| 
|                 This file is confidential and a trade secret of Texas 
|                 Instruments Berlin, AG 
|                 The receipt of or possession of this file does not convey 
|                 any rights to reproduce or disclose its contents or to 
|                 manufacture, use, or sell anything it may describe, in 
|                 whole, or in part, without the specific written consent of 
|                 Texas Instruments Berlin, AG. 
+----------------------------------------------------------------------------- 
|  Purpose :  Dynamic Configuration for GPRS Radio Resource Management (GRLC).
+----------------------------------------------------------------------------- 
*/ 

#ifndef CNF_GRLC_H
#define CNF_GRLC_H


/*==== CONST ================================================================*/
/*
 * CONFIGURATION PARAMETER
 *
 * Description :  The constants define the commands for dynamic
 *                configuration proposals.
 */
#define GRLC_STR_TPC_PWR_PAR "GRLC_TPC_PWR_PAR"
#define GRLC_STR_TPC_FIX_PCL "GRLC_TPC_FIX_PCL"
#define GRLC_STR_TPC_TRACE   "GRLC_TPC_TRACE"
#define GRLC_STR_IM_TRACE    "GRLC_IM_TRACE"
#define GRLC_STR_CCD_USAGE   "GRLC_CCD_USAGE"

#define GRLC_NUM_TPC_PWR_PAR 0
#define GRLC_NUM_TPC_FIX_PCL 1
#define GRLC_NUM_TPC_TRACE   2
#define GRLC_NUM_IM_TRACE    3
#define GRLC_NUM_CCD_USAGE   4
#endif /* !CNF_GRLC_H */