view cdg-hybrid/msg/rr_short_pd.mdf @ 291:a72feaed133a

PWT buzzer driver: conditionalize on TARGET_HAS_BUZZER Here we add a new target config preprocessor symbol TARGET_HAS_BUZZER, currently defined for c11x and c139; later we also expect to have it on for FC Venus, and in FC Magnetite we are going to turn it on for target dsample, just for the sake of completeness and philosophical correctness.
author Mychaela Falconia <falcon@freecalypso.org>
date Sat, 26 Mar 2022 19:31:18 +0000
parents 35f7a1dc9f7d
children
line wrap: on
line source

;********************************************************************************
;*** File           : rr_short_pd.mdf
;*** Creation       : Thu Jun 19 15:32:12 CST 2008
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Air Interface Message Specification
;*** Document Name  : rr_short_pd
;*** Document No.   : 8010.602.03.001
;*** Document Date  : 2003-11-06
;*** Document Status: BEING_PROCESSED
;*** Document Author: LG
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Wed Nov 28 10:21:00 2007"
PRAGMA 	LAST_MODIFIED 	"2003-11-06"
PRAGMA 	ID_AND_VERSION 	"8010.602.03.001"
PRAGMA 	CCDNAME 	RR_SHORT 	; CCD name tag
PRAGMA 	ALLWAYS_ENUM_IN_VAL_FILE 	NO 	; Adds enumerations in the .val file.



CONST 	L3MAX_ACK 	251 	; GSM 4.06, section 5.8.5
CONST 	L3MAX 	251 	; 
CONST 	MAX_NNC 	96 	; Maximum number of cells in Neighbour cell list for Enhanced Measurements
CONST 	MAX_BSICI 	8 	; Maximum invalid BSIC information IE's (21*8-14) / (17+1) = 8
CONST 	MAX_2GEXT 	132 	; Maximum length of MI 2G Extension (21*8-36) = 132



VALTAB 	VAL_bsic_seen
VAL 	0 	NO_INV_BSIC_SEEN 	"No cell with invalid BSIC and allowed NCC part of BSIC is seen."
VAL 	1 	INV_BSIC_SEEN 	"One cell or more with invalid BSIC and allowed NCC part of BSIC is seen."

VALTAB 	VAL_cv_bep
VAL 	0 	CV_BEP_0 	"2.00 > std(BEP)/mean(BEP) > 1.75"
VAL 	1 	CV_BEP_1 	"1.75 > std(BEP)/mean(BEP) > 1.50"
VAL 	2 	CV_BEP_2 	"1.50 > std(BEP)/mean(BEP) > 1.25"
VAL 	3 	CV_BEP_3 	"1.25 > std(BEP)/mean(BEP) > 1.00"
VAL 	4 	CV_BEP_4 	"1.00 > std(BEP)/mean(BEP) > 0.75"
VAL 	5 	CV_BEP_5 	"0.75 > std(BEP)/mean(BEP) > 0.50"
VAL 	6 	CV_BEP_6 	"0.50 > std(BEP)/mean(BEP) > 0.25"
VAL 	7 	CV_BEP_7 	"0.25 > std(BEP)/mean(BEP) > 0.00"

VALTAB 	VAL_dtx_used
VAL 	0 	DTX_USED_NO 	"DTX was not used"
VAL 	1 	DTX_USED_YES 	"DTX was used"

VALTAB 	VAL_inv_bsic_rep
VAL 	0 	NO_REPORT 	"Indicates that GSM cells with invalid BSIC and allowed NCC part should not be reported"
VAL 	1 	YES_REPORT 	"Indicates that GSM cells with invalid BSIC and allowed NCC part should be reported"

VALTAB 	VAL_pow_ctrl
VAL 	0 	POW_CTRL_NO 	"PWRC is not set"
VAL 	1 	POW_CTRL_YES 	"PWRC is set"

VALTAB 	VAL_rep_rate
VAL 	0 	NORMAL_RATE 	"SACCH rate reporting."
VAL 	1 	REDUCED_RATE 	"Reduced reporting rate allowed."

VALTAB 	VAL_report_type
VAL 	0 	RT_EMR 	"MS shall use the Enhanced Measurement Report message, if at least one BSIC is allocated to each BA frequency, otherwise the Measurement Report message."
VAL 	1 	RT_MR 	"The MS shall use the Measurement Report message for reporting."

VALTAB 	VAL_scale
VAL 	0 	SCALE_ZERO_DB 	"0 dB offset is used for the reported RXLEV values"
VAL 	1 	SCALE_TEN_DB 	"+10 dB offset is used for the reported RXLEV values"

VALTAB 	VAL_scale_ord
VAL 	0 	SC_ORD_ZERO_DB 	"0 dB offset, which shall be used for the reported RXLEV values"
VAL 	1 	SC_ORD_TEN_DB 	"+10 dB offset, which shall be used for the reported RXLEV values"
VAL 	2 	SC_ORD_AUTOMATIC 	"automatic offset, which shall be used for the reported RXLEV values"

VALTAB 	VAL_sl2h
VAL 	DEF 	 	"reserved"
VAL 	0 	SL2H_0 	"Short Layer 2 header: UI command frame"




VAR 	ba_start_bsic 	"BA Index Start BSIC" 	
 	5


VAR 	ba_ind 	"BA Sequence Number indication" 	
 	1


VAR 	ba_ind_3g 	"3G BA Sequence Number indication" 	
 	1


VAR 	bsic 	"BSIC" 	
 	6


VAR 	bsic_seen 	"BSIC Seen" 	
 	1

VAL 	@m_rr_short_pd - VAL_bsic_seen@ 	

VAR 	cv_bep 	"Coefficient of Variation of BEP" 	
 	3

VAL 	@m_rr_short_pd - VAL_cv_bep@ 	

VAR 	dtx_used 	"DTX USED" 	
 	1

VAL 	@m_rr_short_pd - VAL_dtx_used@ 	

VAR 	extens 	"Extension" 	
 	1


VAR 	e_len 	"Extension Length" 	
 	8


VAR 	inv_bsic_rep 	"Invalid BSIC reporting" 	
 	1

VAL 	@m_rr_short_pd - VAL_inv_bsic_rep@ 	

VAR 	mean_bep 	"Mean BEP" 	
 	5


VAR 	mp_cm 	"Measurement parameters change mark" 	
 	1


VAR 	msg_type 	"Message Type" 	
 	6


VAR 	mi_idx 	"MI Index" 	
 	4


VAR 	mi_c 	"MI Counter" 	
 	4


VAR 	mr 	"Multiband Reporting" 	
 	2


VAR 	nr_rcvd_bl 	"Number Of Received Blocks" 	
 	5


VAR 	pow_ctrl 	"Power Control Indicator" 	
 	1

VAL 	@m_rr_short_pd - VAL_pow_ctrl@ 	

VAR 	rep_rate 	"Reporting Rate" 	
 	1

VAL 	@m_rr_short_pd - VAL_rep_rate@ 	

VAR 	report_type 	"Report Type" 	
 	1

VAL 	@m_rr_short_pd - VAL_report_type@ 	

VAR 	rxlev 	"RX Level" 	
 	6


VAR 	rep_q 	"Reporting Quantity" 	
 	6


VAR 	rxqual_full 	"RX Quality Full Serving Cell" 	
 	3


VAR 	scale 	"Scale" 	
 	1

VAL 	@m_rr_short_pd - VAL_scale@ 	

VAR 	scale_ord 	"Scale ord" 	
 	2

VAL 	@m_rr_short_pd - VAL_scale_ord@ 	

VAR 	serv_band_rep 	"Serving band reporting" 	
 	2


VAR 	sl2h 	"Short Layer 2 Header" 	
 	2

VAL 	@m_rr_short_pd - VAL_sl2h@ 	




COMP 	emp 	"EM MEASUREMENT Parameters Description"
{
 	CSN1_S1  	mr 	 ; Multiband Reporting
 	CSN1_S1  	serv_band_rep 	 ; Serving band reporting
 	 	scale_ord 	 ; Scale ord
 	CSN1_S1 EXTERN @m_rr_com - report_900@ 	 	report_900 	 ; Reporting 900
 	CSN1_S1 EXTERN @m_rr_com - report_1800@ 	 	report_1800 	 ; Reporting 1800
 	CSN1_S1 EXTERN @m_rr_com - report_400@ 	 	report_400 	 ; Reporting 400
 	CSN1_S1 EXTERN @m_rr_com - report_1900@ 	 	report_1900 	 ; Reporting 1900
 	CSN1_S1 EXTERN @m_rr_com - report_850@ 	 	report_850 	 ; Reporting 850
}



COMP 	i_bsic_i 	"Invalid BSIC Information"
{
 	 	ba_start_bsic 	 ; BA List Index
 	 	bsic 	 ; BSIC
 	 	rxlev 	 ; GSM Reporting Quantity
}



COMP 	mi_ext 	"MI 2G Extension"
{
 	 	e_len 	 ; Extension Length
 	 	extens 	[e_len..MAX_2GEXT] 	 ; Extension
}



COMP 	scdata 	"Serving Cell Data"
{
 	 	dtx_used 	 ; DTX Used
 	 	rxlev 	 ; RX Level
 	 	rxqual_full 	 ; RX Quality Full
 	 	mean_bep 	 ; Mean BEP
 	 	cv_bep 	 ; Coefficient of Variation of BEP
 	 	nr_rcvd_bl 	 ; Number Of Received Blocks
}



COMP 	rep_q_arr 	"Structured Element"
{
 	CSN1_S1  	rep_q 	 ; reported quantity, present only if reported
}



COMP 	em_rep 	"EM Bitmap Type Reporting"
{
 	 	rep_q_arr 	[0..MAX_NNC] 	 ; Reporting Quantities
}






MSG 	u_emr 	uplink 	0b000100 ; Enhanced Measurement Report
{
 	GSM3_V  	msg_type 	 ; Message Type
 	GSM3_V  	sl2h 	 ; Short Layer 2 Header
 	GSM3_V  	ba_ind 	 ; BA Sequence Number indication
 	GSM3_V  	ba_ind_3g 	 ; 3G BA Sequence Number indication
 	GSM3_V  	bsic_seen 	 ; BSIC Seen
 	GSM3_V  	scale 	 ; Scale
 	CSN1_S1  	scdata 	 ; Serving Cell Data
 	CSN1_S1  	i_bsic_i 	[0..MAX_BSICI] 	 ; Invalid BSIC Information
 	CSN1_S1  	em_rep 	 ; EM Bitmap Type Reporting
 	S_PADDING .00101011 (21) ; Spare Padding
}



MSG 	d_meas_inf 	downlink 	0b000101 ; Measurement Information
{
 	GSM3_V  	msg_type 	 ; Message Type
 	GSM3_V  	sl2h 	 ; Short Layer 2 Header
 	GSM3_V  	ba_ind 	 ; BA Sequence Number indication
 	GSM3_V  	ba_ind_3g 	 ; 3G BA Sequence Number indication
 	GSM3_V  	mp_cm 	 ; Measurement parameters change mark
 	GSM3_V  	mi_idx 	 ; MI Index
 	GSM3_V  	mi_c 	 ; MI Counter
 	GSM3_V  	pow_ctrl 	 ; Power Control Indicator
 	GSM3_V  	report_type 	 ; Report Type
 	GSM3_V  	rep_rate 	 ; Reporting Rate
 	GSM3_V  	inv_bsic_rep 	 ; Invalid BSIC Reporting
 	CSN1_S1 EXTERN @m_rr_com - rtdd@ 	 	rtdd 	 ; GPRS Real Time Difference Description
 	CSN1_S1 EXTERN @m_rr_com - gprs_bsic@ 	 	gprs_bsic 	 ; GPRS BSIC Description
 	CSN1_S1 EXTERN @m_rr_com - gprs_rep_prio@ 	 	gprs_rep_prio 	 ; Report Priority
 	CSN1_S1  	emp 	 ; EM Measurement Parameters Description
 	CSN1_S1  	mi_ext 	 ; MI 2G Extension
 	S_PADDING .00101011 (21) ; Spare Padding
}