view src/g23m-aci/aci/aci_bat_em.c @ 214:adfdbcd360fd

backlight evolution: API between Condat driver and MFW With this change, the API between the Condat backlight driver and its user in MFW now carries more abstract backlight state codes (fully off, fully on, in call, charging boot mode) instead of 0-255 levels. This change is needed in order to more properly support different hardware targets with different capabilities and approaches in terms of backlight handling.
author Mychaela Falconia <falcon@freecalypso.org>
date Fri, 23 Apr 2021 23:52:02 +0000
parents fa8dc04885d8
children
line wrap: on
line source

/* 
+----------------------------------------------------------------------------- 
|  Project :  GSM-F&D (8411)
|  Modul   :  ACI_BAT
+-----------------------------------------------------------------------------
|  Copyright 2002 Texas Instruments Berlin, AG
|                 All rights reserved. 
|
|                 This file is confidential and a trade secret of Texas 
|                 Instruments Berlin, AG 
|                 The receipt of or possession of this file does not convey 
|                 any rights to reproduce or disclose its contents or to 
|                 manufacture, use, or sell anything it may describe, in 
|                 whole, or in part, without the specific written consent of 
|                 Texas Instruments Berlin, AG. 
+----------------------------------------------------------------------------- 
|  Purpose :  This BAT wrapper modul is ...
| 
+----------------------------------------------------------------------------- 
*/ 
 
#include "aci_all.h"     /* includes prim.h, which includes p_bat.h */ 
#include "aci_cmh.h"     /* prototypes of sAT_,qAT_,tAT_    */ 
#include "aci_bat_cmh.h" /* prototypes of sBAT_,qBAT_,tBAT_ */


/*
+--------------------------------------------------------------------+
| PROJECT : GSM-F&D (8411)            MODULE  : ACI_BAT              |
| STATE   : code                      ROUTINE : sBAT_PercentEM       |
+--------------------------------------------------------------------+

  PURPOSE : 
*/
GLOBAL T_ACI_BAT_RSLT sBAT_PercentEM       (T_ACI_DTI_PRC_PSI *src_infos_psi,
                                            T_BAT_cmd_send    *cmd)
{
  T_ACI_BAT_RSLT ret = ACI_BAT_FAIL;
  T_BAT_percent_em_mode mode;
  T_BAT_percent_em_sin_type type = BAT_P_EM_TYPE_NOT_PRESENT;
  
  TRACE_FUNCTION ("sBAT_PercentEM()");

  mode = cmd->params.ptr_set_percent_em->mode;
  type = cmd->params.ptr_set_percent_em->sin_type;
  
  if ( (mode NEQ BAT_P_EM_MODE_SIN ) AND (mode NEQ BAT_P_EM_MODE_SIN ) )
  {
    return ACI_BAT_FAIL;
  }

  if ( (mode EQ BAT_P_EM_MODE_SIN ) AND ((type EQ BAT_P_EM_TYPE_NOT_PRESENT) OR ((type < BAT_P_EM_TYPE_SC) AND (type > BAT_P_EM_TYPE_GRLC ))) )
  { 
    return ACI_BAT_FAIL;
  }

  if ( (mode EQ BAT_P_EM_MODE_PCO ) AND (type EQ BAT_P_EM_TYPE_NOT_PRESENT) )
  { 
    return ACI_BAT_FAIL;
  }

  if (type EQ BAT_P_EM_TYPE_NOT_PRESENT)
  {
    type = BAT_P_EM_TYPE_SC;
  }
 
  ret = (T_ACI_BAT_RSLT)sAT_PercentEM((T_ACI_CMD_SRC)src_infos_psi->srcId, 
  	          (T_EM_AT_MODE)mode,(T_EM_AT_TYPE)type);
  return(ret);
}