FreeCalypso > hg > fc-tourmaline
view src/cs/drivers/drv_app/pwr/pwr_api.h @ 268:f2e52cab0a73
abb_inth.c: check all interrupt causes, not just one
The original code used if - else if - else if etc constructs, thus
the first detected interrupt was the only one handled. However,
Iota ITSTATREG is a clear-on-read register, thus if we only handle
the first detected interrupt and skip checking the others, then the
other interrupts will be lost, if more than one interrupt happened
to occur in one ABB interrupt handling cycle - a form of rare race
condition. Change the code to check all interrupts that were read
in this cycle.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Sun, 13 Jun 2021 18:17:53 +0000 |
parents | 4e78acac3d88 |
children |
line wrap: on
line source
/******************************************************************************* * * pwr_api.h * * Purpose: This file contains definitions that can be used by any SWE * for power management services. * * Author Candice Bazanegue (c-brille@ti.com) * * (C) Texas Instruments 2001 * ******************************************************************************/ #ifndef __PWR_API_H__ #define __PWR_API_H__ #include "rv/rv_general.h" typedef T_RV_RET T_POWER_RET; typedef enum { POWER_OK = 0, /* OK */ POWER_ERROR = -1 /* ERROR */ }; /* Define the different charging process states */ typedef enum { CHARGE_STOPPED, TESTING_BATTERY, CI_CHARGE_STARTED, /* constant current charge */ CV_CHARGE_STARTED /* constant voltage charge */ }T_PWR_CHARGING_STATE; /* Define the different states for TIMER0 use */ typedef enum { BATTERY_TYPE_TEST, BATTERY_SHORT_TEST, BATTERY_OPEN_TEST, BATTERY_50UA_TEMP_TEST, BATTERY_10UA_TEMP_TEST, BATTERY_CALIBRATION }T_PWR_TIMER0_STATE; typedef struct { BOOLEAN info_enable; T_RV_RETURN return_path; }T_POWER_INFO; typedef UINT8 T_PWR_PERCENT; typedef struct { T_PWR_PERCENT remain_capa_threshold; T_RV_RETURN return_path; }T_POWER_ALERT; typedef enum { BAT_TEMP_OUTSIDE_LIMITS, BAT_OPEN_TEST_FAILED, BAT_SHORT_TEST_FAILED, BAT_TYPE_UNKNOWN } T_BAT_PROBLEM; /* Prototypes */ T_POWER_RET power_info_register(BOOLEAN info_enable, T_RV_RETURN return_path); T_POWER_RET power_alert_register(T_PWR_PERCENT remain_capa_threshold, T_RV_RETURN return_path); T_POWER_RET power_emergency_register(T_RV_RETURN return_path); T_POWER_RET power_battery_information(void); void pwr_get_bat_info(void); #endif /* __PWR_API_H__ */