!GPRS config: fix long-standing AT+COPS chance hanging bug There has been a long-standing bug in FreeCalypso going back years: sometimes in the AT command bring-up sequence of an ACI-only MS, the AT+COPS command would produce only a power scan followed by cessation of protocol stack activity (only L1 ADC traces), instead of the expected network search sequence. This behaviour was seen in different FC firmware versions going back to Citrine, and seemed to follow some law of chance, not reliably repeatable. This bug has been tracked down and found to be specific to !GPRS configuration, stemming from our TCS2/TCS3 hybrid and reconstruction of !GPRS support that was bitrotten in TCS3.2/LoCosto version. ACI module psa_mms.c, needed only for !GPRS, was missing in the TCS3 version and had to be pulled from TCS2 - but as it turns out, there is a new field in the MMR_REG_REQ primitive that needs to be set correctly, and that psa_mms.c module is the place where this initialization needed to be added.
author Mychaela Falconia <falcon@freecalypso.org>
date Thu, 08 Jun 2023 08:23:37 +0000
parents 35f7a1dc9f7d
children
line wrap: on
line source

;********************************************************************************
;*** File           : 8010_136_simdrv_sap.pdf
;*** Creation       : Wed Mar 11 09:57:50 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : 8010_136_simdrv_sap
;*** Document No.   : 8010.136.03.009
;*** Document Date  : 2004-06-10
;*** Document Status: BEING_PROCESSED
;*** Document Author: FDU
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:27:56 2007"
PRAGMA 	LAST_MODIFIED 	"2004-06-10"
PRAGMA 	ID_AND_VERSION 	"8010.136.03.009"
PRAGMA 	PREFIX 	SIMDRV 	; Prefix for this document
PRAGMA 	ALLWAYS_ENUM_IN_VAL_FILE 	YES 	; Adds enumerations in the .val file.
PRAGMA 	ENABLE_GROUP 	YES 	; Enable h-file grouping
PRAGMA 	COMPATIBILITY_DEFINES 	NO 	; Compatible to the old #defines



CONST 	SIZE_ATR_INFO 	0x21 	; The maximum length of the data returned from the ATR procedure
 	GROUP uicc
CONST 	MIN_RESULT 	0x01 	; Minimum size of the response of any given command
 	GROUP uicc
CONST 	MAX_RESULT 	0x100 	; Maximum size of the response of any given command
 	GROUP uicc
CONST 	MIN_DATA_SIZE 	0x01 	; Minimum length of a data element
 	GROUP uicc
CONST 	MAX_DATA_SIZE 	0xFF 	; Maximum length of a data element
 	GROUP uicc
CONST 	MAX_READERS 	0x02 	; Maximum number of card readers supported.
 	GROUP uicc



VALTAB 	VAL_reset_return_val
 	GROUP uicc
VAL 	0 	SIM_INSERTED 	"A SIM is inserted and ATR/PPS was successful"
VAL 	1 	SIM_NOT_INSERTED 	"No SIM inserted (hardware detected)"
VAL 	2 	INVALID_CARD 	"Card is not responding or gives unintelligible answers, communications time out."
VAL 	3 	ME_FAILURE 	"Power management related problems, e.g. voltage selection"
VAL 	4 	IMPROPER_CALL_BACK 	"simdrv_register function called with pointer improperly set, e.g. NULL."
VAL 	5 	ME_READER_NOT_AVAILABLE 	"The reader requested is not available"

VALTAB 	VAL_len
 	GROUP uicc
VAL 	0x00 - 0x100 	"Range of Length of Data"
VAL 	0xFFFF 	LENGTH_UNKNOWN 	"Indicating that the length expected is unknown."

VALTAB 	VAL_sw1_2
 	GROUP uicc
VAL 	0x0001 	ERR_NOCARD 	"No SIM inserted (hardware detected)"
VAL 	0x0002 	ERR_NOT_RESET 	"A reset has not been performed on the driver with the requested Id."
VAL 	0x0003 	ERR_ME_FAIL 	"Unrecoverable ME failure (for instance interrupt fails to occur)"
VAL 	0x0004 	ERR_RETRY_FAIL 	"ME/SIM communication failed after certain retries, SIM reset required"
VAL 	0x0005 	ERR_PARAM_WRONG 	"A driver function is called with invalid parameters"

VALTAB 	VAL_cla
 	GROUP uicc
VAL 	0xA0 	GSM_CLASS_BYTE 	"GSM Class byte according to [GSM 11.11 / 3GPP 51.011]"
VAL 	0x80 	UMTS_CLASS_BYTE 	"UMTS Class byte according to [ETSI 102 221 10.1.2]"
VAL 	0x00 	UICC_CLASS_BYTE 	"UICC Class byte according to [ISO 7816-4]"

VALTAB 	VAL_ins
 	GROUP uicc
VAL 	0xA4 	INS_SELECT 	"Select Instruction"
VAL 	0xF2 	INS_STATUS 	"Status Instruction"
VAL 	0xB0 	INS_READ_BINARY 	"Read Binary Instruction"
VAL 	0xD6 	INS_UPDATE_BINARY 	"Update Binary Instruction"
VAL 	0xB2 	INS_READ_RECORD 	"Read Record Instruction"
VAL 	0xDC 	INS_UPDATE_RECORD 	"Update Record Instruction"
VAL 	0xA2 	INS_SEEK 	"Seek Instruction"
VAL 	0x32 	INS_INCREASE 	"Increase Instruction"
VAL 	0x20 	INS_VERIFY_CHV 	"Verify Chv Instruction"
VAL 	0x24 	INS_CHANGE_CHV 	"Change Chv Instruction"
VAL 	0x26 	INS_DISABLE_CHV 	"Disable Chv Instruction"
VAL 	0x28 	INS_ENABLE_CHV 	"Ensable Chv Instruction"
VAL 	0x2C 	INS_UNBLOCK_CHV 	"Unblock Chv Instruction"
VAL 	0x04 	INS_INVALIDATE 	"Invalidate Instruction"
VAL 	0x44 	INS_REHABILITATE 	"Rehabilitate Instruction"
VAL 	0x88 	INS_AUTHENTICATE 	"Run GSM Algorithm (2/2.5G) / Authenticate (3G) Instruction"
VAL 	0x10 	INS_TERMINAL_PROFILE 	"Terminal Profile Instruction"
VAL 	0xC2 	INS_ENVELOPE 	"Envelope Instruction"
VAL 	0x12 	INS_FETCH 	"Fetch Instruction"
VAL 	0x14 	INS_TERMINAL_RESPONSE 	"Terminal Response Instruction"
VAL 	0xC0 	INS_GET_RESPONSE 	"Get Response Instruction"

VALTAB 	VAL_voltage_select
 	GROUP uicc
VAL 	0 	REQ_VOLTAGE_SEL 	"The SIM reader driver shall perform voltage selection"
VAL 	1 	OMIT_VOLTAGE_SEL 	"The SIM reader driver shall restart with the current voltage"

VALTAB 	VAL_config_requested
 	GROUP uicc
VAL 	0x00 	OMIT_CONFIG_CHARACTERISTICS 	"PS Shall not retrieve Configuration Characteristics"
VAL 	0x01 	REQUEST_CONFIG_CHARACTERISTICS 	"PS Shall retrieve Configuration Characteristics"

VALTAB 	VAL_reader_id
 	GROUP uicc
VAL 	01 - MAX_READERS 	"Range of Id's of readers"




VAR 	insert_ptr 	"insert pointer" 	L
 	GROUP uicc


VAR 	remove_ptr 	"remove pointer" 	L
 	GROUP uicc


VAR 	atr_string 	"SIM Card Answer to reset string" 	B
 	GROUP uicc


VAR 	reset_return_val 	"Reset return value" 	B
 	GROUP uicc

VAL 	@p_8010_136_simdrv_sap - VAL_reset_return_val@ 	

VAR 	result 	"Result byte" 	B
 	GROUP uicc


VAR 	len 	"Maximum length of expected data" 	S
 	GROUP uicc

VAL 	@p_8010_136_simdrv_sap - VAL_len@ 	

VAR 	data 	"Data element" 	B
 	GROUP uicc


VAR 	sw1_2 	"Status Words" 	S
 	GROUP uicc

VAL 	@p_8010_136_simdrv_sap - VAL_sw1_2@ 	

VAR 	cla 	"Class Byte" 	B
 	GROUP uicc

VAL 	@p_8010_136_simdrv_sap - VAL_cla@ 	

VAR 	ins 	"instruction code" 	B
 	GROUP uicc

VAL 	@p_8010_136_simdrv_sap - VAL_ins@ 	

VAR 	voltage_select 	"Perform Voltage Selection" 	B
 	GROUP uicc

VAL 	@p_8010_136_simdrv_sap - VAL_voltage_select@ 	

VAR 	p1 	"Parameter 1 of the SIM APDU" 	B
 	GROUP uicc


VAR 	p2 	"Parameter 2 of the SIM APDU" 	B
 	GROUP uicc


VAR 	config_requested 	"Configuration Characteristics requested" 	B
 	GROUP uicc

VAL 	@p_8010_136_simdrv_sap - VAL_config_requested@ 	

VAR 	reader_id 	"Reader Id" 	B
 	GROUP uicc

VAL 	@p_8010_136_simdrv_sap - VAL_reader_id@ 	

VAR 	uicc_characteristics 	"UICC Characteristics" 	B
 	GROUP uicc





COMP 	atr_string_info 	 "SIM Card Info"
 	GROUP uicc
{
 	atr_string 	[2..SIZE_ATR_INFO] 	 ; SIM Card Answer to reset string
}



COMP 	result_info 	 "Result Buffer"
 	GROUP uicc
{
 	len 	 ; Length of expected data
 	result 	DYN[MIN_RESULT..MAX_RESULT] 	 ; Result byte
}



COMP 	data_info 	 "Data element info"
 	GROUP uicc
{
 	data 	DYN[MIN_DATA_SIZE..MAX_DATA_SIZE] 	 ; Data element
}



COMP 	cmd_header 	 "Transparent command header"
 	GROUP uicc
{
 	cla 	 ; Class Byte value
 	ins 	 ; Instruction Code
 	p1 	 ; Parameter P1
 	p2 	 ; Parameter P2
}



COMP 	config_characteristics 	 "Configuration Characteristics"
 	GROUP uicc
{
 	uicc_characteristics 	 ; UICC Characteristics
}






; SIMDRV_DUMMY 	0x80FF009A



PRIM 	SIMDRV_DUMMY 	0x80FF009A
 	GROUP uicc
{
 	atr_string_info 	PTR 	 ; SIM Card Info
 	reset_return_val 	 ; Return Value
 	result_info 	PTR 	 ; Result Buffer
 	len 	 ; Length of expected data
 	data_info 	PTR 	 ; Update Data Element
 	sw1_2 	 ; Status Words
 	cla 	 ; Class Byte
 	ins 	 ; Instruction Code
 	cmd_header 	 ; Transparent command header
 	voltage_select 	 ; Perform Voltage Selection
 	p1 	 ; SIM Command Parameters
 	p2 	 ; SIM Command Parameters
 	config_requested 	 ; Configuration Characteristics requested
 	config_characteristics 	PTR 	 ; Configuration Characteristics
 	reader_id 	 ; Reader Id