TCH tap: extend DL sniffing feature to support CSD modes
Our debug feature for TCH DL sniffing reads the content of the DSP's
a_dd_0 buffer (or a_dd_1 for TCH/H subchannel 1) at appropriate times
and forwards captured bits to the host. This feature was originally
implemented for TCH/FS, TCH/EFS and TCH/HS - now extend it to cover
TCH/F data modes too.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Mon, 25 Nov 2024 23:33:27 +0000 |
parents | 35f7a1dc9f7d |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : rrlc.pdf ;*** Creation : Wed Mar 11 09:58:47 CST 2009 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : rrlc ;*** Document No. : 8443.101.02.008 ;*** Document Date : 2002-10-11 ;*** Document Status: BEING_PROCESSED ;*** Document Author: VK ;******************************************************************************** PRAGMA SRC_FILE_TIME "Thu Nov 29 09:52:52 2007" PRAGMA LAST_MODIFIED "2002-10-11" PRAGMA ID_AND_VERSION "8443.101.02.008" CONST MAX_NCELL_EOTD_L1 12 ; Max no. of NC observed for EOTD CONST MAX_NCELL_EOTD 15 ; Max no. of NC reported in the Measurement Assistance Data Element (3GPP 04.31) CONST MAX_NCELL_EOTD_SI 32 ; Max no. of NC reported in the Measurement Assistance Data SI List Element (3GPP 04.31) CONST XCOR_NO 18 ; Cross-correlation values (real & imaginary) VALTAB VAL_cause VAL 0 LCS_OK "no error" VAL 10 LCS_WRONG_BTS "Serving Cell BTS differs from Reference BTS" VAL 20 LCS_HANDOVER "handover occured during Position Measurement procedure" VALTAB VAL_sb_flag VAL 0 EOTD_INVALID "invalid data" VAL 1 EOTD_VALID "valid data" VALTAB VAL_eotd_mode VAL 0 EOTD_IDLE "Idle mode" VAL 1 EOTD_DEDIC "Dedicated or packet mode" VALTAB VAL_exp_otd VAL 0 - 1250 "The used resolution is 1 bits. This OTD value is the OTD value of TS0s (i.e. the difference in starting of TS0), not only the OTD between starts of bursts expected OTD between the scell and the specified cell. Note: 1250 is interpreted as 0" VALTAB VAL_fn VAL 2715648 FNMAX "max Frame Number + 1 (26*51*2048)" VALTAB VAL_mfrm_offset VAL 0 - 51 "multiframes/ 51 is interpreted as 0" VALTAB VAL_otd_type VAL 0 ROUGH_RTD "only rough RTD has been provided by the NW" VAL 1 EXPECTED_OTD "only expectedOTD has been provided by the NW" VAL 2 BOTH_OTD "Both OTD / RTD types have been provided by the NW" VALTAB VAL_rough_rtd VAL 0 - 1250 "rough RTD in bits (see expected OTD)" VALTAB VAL_tav VAL 0 - 63 "valid TA values" VAL 255 TA_NOT_AVAIL "no Timing Advance in Idle Mode" VALTAB VAL_uncertainty VAL 0 UNC_MAX_2BIT "uncertainty in bits. 0 - 2 bits" VAL 1 UNC_MAX_4BIT "uncertainty in bits. 3 - 4 bits" VAL 2 UNC_MAX_8BIT "uncertainty in bits. 5 - 8 bits" VAL 3 UNC_MAX_12BIT "uncertainty in bits. 9 - 12 bits" VAL 4 UNC_MAX_16BIT "uncertainty in bits. 13 - 16 bits" VAL 5 UNC_MAX_22BIT "uncertainty in bits. 17 - 22 bits" VAL 6 UNC_MAX_30BIT "uncertainty in bits. 23 - 30 bits" VAL 7 UNC_GT_30BIT "uncertainty in bits. > 30 bits" VAR arfcn "Channel number" S VAR bsic "Base station ID code" B VAR cause "Cause Identifier" B VAL @p_rrlc - VAL_cause@ VAR cell_id "Cell ID" S VAR eotd_crosscor "Cross-correlation data" T VAR sb_flag "data on SCH could be decoded, 'sb' stems from Sch Burst" B VAL @p_rrlc - VAL_sb_flag@ VAR eotd_mode "Operation mode" B VAL @p_rrlc - VAL_eotd_mode@ VAR exp_otd "expectedOTD" S VAL @p_rrlc - VAL_exp_otd@ VAR fn "full frame number" L VAL @p_rrlc - VAL_fn@ VAR lac "Location area code" S VAR mcc "Mobile country code" B VAR mfrm_offset "multiframe offset" B VAL @p_rrlc - VAL_mfrm_offset@ VAR mnc "Mobile country code" B VAR time_tag "Nominal Position" L VAR otd_type "OTD type" B VAL @p_rrlc - VAL_otd_type@ VAR req_id "Request Identifier" S VAR rough_rtd "rough RTD" S VAL @p_rrlc - VAL_rough_rtd@ VAR d_eotd_nrj "Signal level" L VAR tav "Timing advance" B VAL @p_rrlc - VAL_tav@ VAR uncertainty "Uncertainty of expected OTD" B VAL @p_rrlc - VAL_uncertainty@ COMP assist_data "Assistance Data" { arfcn ; channel number bsic ; Base Station Id Code mfrm_offset ; multiframe offset otd_type ; otd type exp_otd ; expected otd uncertainty ; uncertainty of exp. otd rough_rtd ; rough rtd } COMP eotd_sc_res "EOTD SC Results at start of measurement" { sb_flag ; Valid flag; named 'Data Valid' by Lower Layer task bsic ; base station identity code arfcn ; channel number eotd_crosscor [XCOR_NO] ; Cross correlation; real and imaginary parts for m=p-4 tp p+4 d_eotd_nrj ; Sum of Amplitudes; named 'RSSI' by Cursor task time_tag ; Time tag; named 'Nominal Position' by Lower Layer task; in of case 1st SC measurement time_tag takes on the SCH Frame Number } TYPEDEF COMP eotd_sc_res eotd_sc_res1 "EOTD SC Results at stop of measurement" TYPEDEF COMP eotd_sc_res eotd_nc_res "EOTD NC Results" ; RRLC_MEAS_REQ 0x80000040 ; RRLC_MEAS_IND 0x80004040 ; RRLC_ERROR_IND 0x80014040 PRIM RRLC_MEAS_REQ 0x80000040 { req_id ; Request ID < () arfcn > ; Reference BTS ARFCN < () bsic > ; Reference BTS BSIC < () assist_data [0..MAX_NCELL_EOTD] > ; Assistance Data; The network may provide Assistance Data for up to 15 BTSs, however Layer1 can cope with 12 at one time. ALR will perform the mapping 15->12? } PRIM RRLC_MEAS_IND 0x80004040 { mcc [3] ; Mobile Coutry Code mnc [3] ; Mobile Network Code lac ; Location Area Code cell_id ; CellID eotd_mode ; Mode req_id ; Request Ident; passed from MPH tav ; Timing Advance; passed from MPH fn ; Frame Number; passed from MPH eotd_sc_res ; EOTD SC Results; passed from MPH eotd_sc_res1 ; EOTD SC Results; passed from MPH eotd_nc_res [1..MAX_NCELL_EOTD_L1] ; EOTD NC Results; passed from MPH } PRIM RRLC_ERROR_IND 0x80014040 { cause ; cause ID }