view compal/c139-rssi @ 361:5d1c186cc3cf

fluid-mnf/target-bin/cmd39.m0: hand-crafted by copying cmd.m0 and manually patching the S3 record that contains the 16-bit word at 0x1140, the literal pool DPLL init constant used by hardware_init_calypso()
author Mychaela Falconia <falcon@freecalypso.org>
date Sat, 14 Mar 2020 19:33:52 +0000
parents 493bfe847128
children
line wrap: on
line source

The following RSSI display thresholds have been observed on a North American
C139 phone (sw ver 1.0.07) tested on our CMU200 in the PCS band; each number of
bars given below appears when the BCCH signal level on the CMU200 is set to
greater than or equal to the corresponding number:

5 bars threshold: -86 dBm
4 bars threshold: -94 dBm
3 bars threshold: -98 dBm
2 bars threshold: -102 dBm

1 bar appears until complete loss of service

No Pirelli-like 5 dB hysteresis is seen on this phone.