FreeCalypso > hg > freecalypso-sw
comparison gsm-fw/cdg/sap/8010_136_SIMDRV_SAP.pdf @ 652:a39ec5bb5549
gsm-fw/cdg: imported MDF and PDF files from LoCosto, along with XML sources
author | Michael Spacefalcon <msokolov@ivan.Harhan.ORG> |
---|---|
date | Thu, 25 Sep 2014 08:46:13 +0000 |
parents | |
children |
comparison
equal
deleted
inserted
replaced
651:806828641b21 | 652:a39ec5bb5549 |
---|---|
1 ;******************************************************************************** | |
2 ;*** File : 8010_136_simdrv_sap.pdf | |
3 ;*** Creation : Wed Mar 11 09:57:50 CST 2009 | |
4 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 | |
5 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 | |
6 ;******************************************************************************** | |
7 ;*** Document Type : Service Access Point Specification | |
8 ;*** Document Name : 8010_136_simdrv_sap | |
9 ;*** Document No. : 8010.136.03.009 | |
10 ;*** Document Date : 2004-06-10 | |
11 ;*** Document Status: BEING_PROCESSED | |
12 ;*** Document Author: FDU | |
13 ;******************************************************************************** | |
14 | |
15 | |
16 | |
17 PRAGMA SRC_FILE_TIME "Thu Nov 29 09:27:56 2007" | |
18 PRAGMA LAST_MODIFIED "2004-06-10" | |
19 PRAGMA ID_AND_VERSION "8010.136.03.009" | |
20 PRAGMA PREFIX SIMDRV ; Prefix for this document | |
21 PRAGMA ALLWAYS_ENUM_IN_VAL_FILE YES ; Adds enumerations in the .val file. | |
22 PRAGMA ENABLE_GROUP YES ; Enable h-file grouping | |
23 PRAGMA COMPATIBILITY_DEFINES NO ; Compatible to the old #defines | |
24 | |
25 | |
26 | |
27 CONST SIZE_ATR_INFO 0x21 ; The maximum length of the data returned from the ATR procedure | |
28 GROUP uicc | |
29 CONST MIN_RESULT 0x01 ; Minimum size of the response of any given command | |
30 GROUP uicc | |
31 CONST MAX_RESULT 0x100 ; Maximum size of the response of any given command | |
32 GROUP uicc | |
33 CONST MIN_DATA_SIZE 0x01 ; Minimum length of a data element | |
34 GROUP uicc | |
35 CONST MAX_DATA_SIZE 0xFF ; Maximum length of a data element | |
36 GROUP uicc | |
37 CONST MAX_READERS 0x02 ; Maximum number of card readers supported. | |
38 GROUP uicc | |
39 | |
40 | |
41 | |
42 VALTAB VAL_reset_return_val | |
43 GROUP uicc | |
44 VAL 0 SIM_INSERTED "A SIM is inserted and ATR/PPS was successful" | |
45 VAL 1 SIM_NOT_INSERTED "No SIM inserted (hardware detected)" | |
46 VAL 2 INVALID_CARD "Card is not responding or gives unintelligible answers, communications time out." | |
47 VAL 3 ME_FAILURE "Power management related problems, e.g. voltage selection" | |
48 VAL 4 IMPROPER_CALL_BACK "simdrv_register function called with pointer improperly set, e.g. NULL." | |
49 VAL 5 ME_READER_NOT_AVAILABLE "The reader requested is not available" | |
50 | |
51 VALTAB VAL_len | |
52 GROUP uicc | |
53 VAL 0x00 - 0x100 "Range of Length of Data" | |
54 VAL 0xFFFF LENGTH_UNKNOWN "Indicating that the length expected is unknown." | |
55 | |
56 VALTAB VAL_sw1_2 | |
57 GROUP uicc | |
58 VAL 0x0001 ERR_NOCARD "No SIM inserted (hardware detected)" | |
59 VAL 0x0002 ERR_NOT_RESET "A reset has not been performed on the driver with the requested Id." | |
60 VAL 0x0003 ERR_ME_FAIL "Unrecoverable ME failure (for instance interrupt fails to occur)" | |
61 VAL 0x0004 ERR_RETRY_FAIL "ME/SIM communication failed after certain retries, SIM reset required" | |
62 VAL 0x0005 ERR_PARAM_WRONG "A driver function is called with invalid parameters" | |
63 | |
64 VALTAB VAL_cla | |
65 GROUP uicc | |
66 VAL 0xA0 GSM_CLASS_BYTE "GSM Class byte according to [GSM 11.11 / 3GPP 51.011]" | |
67 VAL 0x80 UMTS_CLASS_BYTE "UMTS Class byte according to [ETSI 102 221 10.1.2]" | |
68 VAL 0x00 UICC_CLASS_BYTE "UICC Class byte according to [ISO 7816-4]" | |
69 | |
70 VALTAB VAL_ins | |
71 GROUP uicc | |
72 VAL 0xA4 INS_SELECT "Select Instruction" | |
73 VAL 0xF2 INS_STATUS "Status Instruction" | |
74 VAL 0xB0 INS_READ_BINARY "Read Binary Instruction" | |
75 VAL 0xD6 INS_UPDATE_BINARY "Update Binary Instruction" | |
76 VAL 0xB2 INS_READ_RECORD "Read Record Instruction" | |
77 VAL 0xDC INS_UPDATE_RECORD "Update Record Instruction" | |
78 VAL 0xA2 INS_SEEK "Seek Instruction" | |
79 VAL 0x32 INS_INCREASE "Increase Instruction" | |
80 VAL 0x20 INS_VERIFY_CHV "Verify Chv Instruction" | |
81 VAL 0x24 INS_CHANGE_CHV "Change Chv Instruction" | |
82 VAL 0x26 INS_DISABLE_CHV "Disable Chv Instruction" | |
83 VAL 0x28 INS_ENABLE_CHV "Ensable Chv Instruction" | |
84 VAL 0x2C INS_UNBLOCK_CHV "Unblock Chv Instruction" | |
85 VAL 0x04 INS_INVALIDATE "Invalidate Instruction" | |
86 VAL 0x44 INS_REHABILITATE "Rehabilitate Instruction" | |
87 VAL 0x88 INS_AUTHENTICATE "Run GSM Algorithm (2/2.5G) / Authenticate (3G) Instruction" | |
88 VAL 0x10 INS_TERMINAL_PROFILE "Terminal Profile Instruction" | |
89 VAL 0xC2 INS_ENVELOPE "Envelope Instruction" | |
90 VAL 0x12 INS_FETCH "Fetch Instruction" | |
91 VAL 0x14 INS_TERMINAL_RESPONSE "Terminal Response Instruction" | |
92 VAL 0xC0 INS_GET_RESPONSE "Get Response Instruction" | |
93 | |
94 VALTAB VAL_voltage_select | |
95 GROUP uicc | |
96 VAL 0 REQ_VOLTAGE_SEL "The SIM reader driver shall perform voltage selection" | |
97 VAL 1 OMIT_VOLTAGE_SEL "The SIM reader driver shall restart with the current voltage" | |
98 | |
99 VALTAB VAL_config_requested | |
100 GROUP uicc | |
101 VAL 0x00 OMIT_CONFIG_CHARACTERISTICS "PS Shall not retrieve Configuration Characteristics" | |
102 VAL 0x01 REQUEST_CONFIG_CHARACTERISTICS "PS Shall retrieve Configuration Characteristics" | |
103 | |
104 VALTAB VAL_reader_id | |
105 GROUP uicc | |
106 VAL 01 - MAX_READERS "Range of Id's of readers" | |
107 | |
108 | |
109 | |
110 | |
111 VAR insert_ptr "insert pointer" L | |
112 GROUP uicc | |
113 | |
114 | |
115 VAR remove_ptr "remove pointer" L | |
116 GROUP uicc | |
117 | |
118 | |
119 VAR atr_string "SIM Card Answer to reset string" B | |
120 GROUP uicc | |
121 | |
122 | |
123 VAR reset_return_val "Reset return value" B | |
124 GROUP uicc | |
125 | |
126 VAL @p_8010_136_simdrv_sap - VAL_reset_return_val@ | |
127 | |
128 VAR result "Result byte" B | |
129 GROUP uicc | |
130 | |
131 | |
132 VAR len "Maximum length of expected data" S | |
133 GROUP uicc | |
134 | |
135 VAL @p_8010_136_simdrv_sap - VAL_len@ | |
136 | |
137 VAR data "Data element" B | |
138 GROUP uicc | |
139 | |
140 | |
141 VAR sw1_2 "Status Words" S | |
142 GROUP uicc | |
143 | |
144 VAL @p_8010_136_simdrv_sap - VAL_sw1_2@ | |
145 | |
146 VAR cla "Class Byte" B | |
147 GROUP uicc | |
148 | |
149 VAL @p_8010_136_simdrv_sap - VAL_cla@ | |
150 | |
151 VAR ins "instruction code" B | |
152 GROUP uicc | |
153 | |
154 VAL @p_8010_136_simdrv_sap - VAL_ins@ | |
155 | |
156 VAR voltage_select "Perform Voltage Selection" B | |
157 GROUP uicc | |
158 | |
159 VAL @p_8010_136_simdrv_sap - VAL_voltage_select@ | |
160 | |
161 VAR p1 "Parameter 1 of the SIM APDU" B | |
162 GROUP uicc | |
163 | |
164 | |
165 VAR p2 "Parameter 2 of the SIM APDU" B | |
166 GROUP uicc | |
167 | |
168 | |
169 VAR config_requested "Configuration Characteristics requested" B | |
170 GROUP uicc | |
171 | |
172 VAL @p_8010_136_simdrv_sap - VAL_config_requested@ | |
173 | |
174 VAR reader_id "Reader Id" B | |
175 GROUP uicc | |
176 | |
177 VAL @p_8010_136_simdrv_sap - VAL_reader_id@ | |
178 | |
179 VAR uicc_characteristics "UICC Characteristics" B | |
180 GROUP uicc | |
181 | |
182 | |
183 | |
184 | |
185 | |
186 COMP atr_string_info "SIM Card Info" | |
187 GROUP uicc | |
188 { | |
189 atr_string [2..SIZE_ATR_INFO] ; SIM Card Answer to reset string | |
190 } | |
191 | |
192 | |
193 | |
194 COMP result_info "Result Buffer" | |
195 GROUP uicc | |
196 { | |
197 len ; Length of expected data | |
198 result DYN[MIN_RESULT..MAX_RESULT] ; Result byte | |
199 } | |
200 | |
201 | |
202 | |
203 COMP data_info "Data element info" | |
204 GROUP uicc | |
205 { | |
206 data DYN[MIN_DATA_SIZE..MAX_DATA_SIZE] ; Data element | |
207 } | |
208 | |
209 | |
210 | |
211 COMP cmd_header "Transparent command header" | |
212 GROUP uicc | |
213 { | |
214 cla ; Class Byte value | |
215 ins ; Instruction Code | |
216 p1 ; Parameter P1 | |
217 p2 ; Parameter P2 | |
218 } | |
219 | |
220 | |
221 | |
222 COMP config_characteristics "Configuration Characteristics" | |
223 GROUP uicc | |
224 { | |
225 uicc_characteristics ; UICC Characteristics | |
226 } | |
227 | |
228 | |
229 | |
230 | |
231 | |
232 | |
233 ; SIMDRV_DUMMY 0x80FF009A | |
234 | |
235 | |
236 | |
237 PRIM SIMDRV_DUMMY 0x80FF009A | |
238 GROUP uicc | |
239 { | |
240 atr_string_info PTR ; SIM Card Info | |
241 reset_return_val ; Return Value | |
242 result_info PTR ; Result Buffer | |
243 len ; Length of expected data | |
244 data_info PTR ; Update Data Element | |
245 sw1_2 ; Status Words | |
246 cla ; Class Byte | |
247 ins ; Instruction Code | |
248 cmd_header ; Transparent command header | |
249 voltage_select ; Perform Voltage Selection | |
250 p1 ; SIM Command Parameters | |
251 p2 ; SIM Command Parameters | |
252 config_requested ; Configuration Characteristics requested | |
253 config_characteristics PTR ; Configuration Characteristics | |
254 reader_id ; Reader Id | |
255 uicc_characteristics ; UICC Characteristics | |
256 } | |
257 | |
258 | |
259 | |
260 | |
261 | |
262 | |
263 | |
264 | |
265 |