diff gsm-fw/bsp/abb+spi/abb_inline.h @ 587:cc0944d35698

gsm-fw/bsp/abb+spi/*.h: formatting fixes (line length and tabs)
author Michael Spacefalcon <msokolov@ivan.Harhan.ORG>
date Sun, 17 Aug 2014 00:08:50 +0000
parents 971e84124a6f
children
line wrap: on
line diff
--- a/gsm-fw/bsp/abb+spi/abb_inline.h	Fri Aug 15 22:29:30 2014 +0000
+++ b/gsm-fw/bsp/abb+spi/abb_inline.h	Sun Aug 17 00:08:50 2014 +0000
@@ -1,30 +1,30 @@
-/**********************************************************************************/
-/*            TEXAS INSTRUMENTS INCORPORATED PROPRIETARY INFORMATION              */
-/*                                                                                */
-/*   Property of Texas Instruments -- For  Unrestricted  Internal  Use  Only      */
-/*   Unauthorized reproduction and/or distribution is strictly prohibited.  This  */
-/*   product  is  protected  under  copyright  law  and  trade  secret law as an  */
-/*   unpublished work.  Created 1987, (C) Copyright 1997 Texas Instruments.  All  */
-/*   rights reserved.                                                             */
-/*                                                                                */
-/*                                                                                */
-/*   Filename          : abb_inline.h                                             */
-/*                                                                                */
-/*   Description       : inline functions to drive the ABB device.                */
-/*                       The Serial Port Interface is used to connect the TI 	  */
-/*						 Analog BaseBand (ABB).				    				  */
-/*						 It is assumed that the ABB is connected as the SPI       */																				  
-/*                       device 0.                                                */																				  
-/*																				  */
-/*   Author            : Pascal PUEL                                              */
-/*                                                                                */
-/*   Version number   : 1.0                                                       */
-/*                                                                                */
-/*   Date and time    : Dec 2002                                                  */
-/*                                                                                */
-/*   Previous delta   : Creation                                                  */
-/*                                                                                */
-/**********************************************************************************/
+/******************************************************************************/
+/*          TEXAS INSTRUMENTS INCORPORATED PROPRIETARY INFORMATION            */
+/*                                                                            */
+/* Property of Texas Instruments -- For  Unrestricted  Internal  Use  Only    */
+/* Unauthorized reproduction and/or distribution is strictly prohibited.  This*/
+/* product  is  protected  under  copyright  law  and  trade  secret law as an*/
+/* unpublished work.  Created 1987, (C) Copyright 1997 Texas Instruments.  All*/
+/* rights reserved.                                                           */
+/*                                                                            */
+/*                                                                            */
+/* Filename          : abb_inline.h                                           */
+/*                                                                            */
+/* Description       : inline functions to drive the ABB device.              */
+/*                     The Serial Port Interface is used to connect the TI    */
+/*		       Analog BaseBand (ABB).				      */
+/*		       It is assumed that the ABB is connected as the SPI     */
+/*                     device 0.                                              */
+/*									      */
+/* Author            : Pascal PUEL                                            */
+/*                                                                            */
+/* Version number   : 1.0                                                     */
+/*                                                                            */
+/* Date and time    : Dec 2002                                                */
+/*                                                                            */
+/* Previous delta   : Creation                                                */
+/*                                                                            */
+/******************************************************************************/
 
 #ifndef __ABB_INLINE_H__
 #define __ABB_INLINE_H__
@@ -94,7 +94,7 @@
 /* ABB_ReadRegister()                                                    */
 /*                                                                       */
 /* This function reads the ABB register "abb_reg" and returns            */
-/* the real register value.                                              */                        
+/* the real register value.                                              */
 /*                                                                       */
 /*-----------------------------------------------------------------------*/
 static inline SYS_UWORD16 ABB_ReadRegister(SYS_UWORD16 abb_reg)