FreeCalypso > hg > freecalypso-tools
diff doc/RF-cal/Test-system-interface @ 192:bab88077deba
doc/RF-cal/Test-system-interface written
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Sun, 23 Apr 2017 21:03:44 +0000 |
parents | |
children |
line wrap: on
line diff
--- /dev/null Thu Jan 01 00:00:00 1970 +0000 +++ b/doc/RF-cal/Test-system-interface Sun Apr 23 21:03:44 2017 +0000 @@ -0,0 +1,46 @@ +The Test System Interface Daemon (TSID) will provide a connection-oriented +(SOCK_STREAM) UNIX domain local socket at /tmp/fc_rftest_socket, and will speak +an ASCII line-based command-response protocol on this socket. All command and +response lines will end with \n only (no \r), and each TSID response including +the initial greeting on connection establishment will begin with a '+' or '-' +character to indicate OK or error, respectively, like in POP3. + +The following commands are currently defined: + +vcxo-cal-setup band arfcn + +This command is sent to the TSID to prepare the RF test system for the VCXO +calibration procedure. The first argument after the command keyword is the +band to be used (850, 900, 1800 or 1900) and the second argument is the ARFCN +in that band on which the DUT will be transmitting. + +freq-meas hint + +This command directs the RF test system to take a frequency offset measurement +(vcxo-cal-setup must have been performed previously) and report it back to the +client in the response line. The hint argument after the freq-meas keyword will +be sent by the VCXO calibration program (fc-rfcal-vcxo) to tell the RF test +system what kind of frequency offset measurement is being made, i.e., which step +in the VCXO calibration sequence is being performed; the hint keywords remain +to be defined. + +signal-gen-setup band + +This command is sent to the TSID to prepare the RF test system for tests in +which the latter acts as a signal generator. The argument after the command +keyword is the band number (850, 900, 1800 or 1900), and it selects the +downlink frequency band in which the signal generator will need to operate. + +signal-gen-sine arfcn offset level + +This command directs the RF test system to turn on its signal generator and put +out a pure sine wave at the frequency corresponding to the specified ARFCN (in +the downlink band previously selected with signal-get-setup) plus the specified +offset in kHz (-67 or +67 with TI's Rx path calibration procedures), and at the +specified Tx power level in dBm. + +signal-gen-off + +Turn off the signal generator. + +The commands for Tx power level calibration remain to be defined.