# The following parameters go into the <p command sent to the boot ROM

pll-config 4/1		# 26 MHz in, PLL&DSP @ 104 MHz, ARM @ 52 MHz
rhea-cntl 0x00		# fastest setting, used by OsmocomBB, presumably correct

# The remaining settings are carried out via loadagent commands
init-script pirelli.init

# Flash type and chip select base addresses
flash pl129n 0x03000000 0x02000000

# On this phone the current best exit strategy is jump0.
# A Iota power-off, even if we implement one, won't be any different:
# having the serial connection implies a USB connection, that in turn
# implies having VBUS, and thus a Iota power-off will immediately
# result in another power-on for charger-insert.

exit-mode jump0