view pathloss/pcs.in @ 94:f9ef582c199c

tfo-ut: check in tfo-fr.bin and tfo-efr.bin Each of these binary files is an extract from MSC-side E1 timeslot recording in a Nokia TCSM2 TFO session involving a cross-connect between two TRAU channels. The extracts have been chosen to begin at the point where the TRAU starts emitting TFO frames, thereby beginning with a series of TFO frames that contain an embedded TFO_TRANS message. In each experiment, one of the two cross-connected TRAU channels emitted two "plain" TFO frames (not containing embedded TFO messages) in between the initial embedded TFO_TRANS and the subsequent embedded TFO_REQ_L; this channel was chosen for the present extracts. Each extract is thus 2560 PCM samples, containing 16 aligned TFO frames: 5 carrying TFO_TRANS, 2 plain, 9 carrying TFO_REQ_L.
author Mychaela Falconia <falcon@freecalypso.org>
date Tue, 18 Mar 2025 22:56:23 +0000
parents b3f04535eb14
children
line wrap: on
line source

# Attempt to model path loss in PCS band with a high-power BTS,
# as we presume T-Mobile must have operated in the Olden Days.

band PCS

bts-param 43 -109 11	# Tx power, Rx sensitivity, antenna gain

bts-height 45 ft

# standard MS

ms-param 30 -102	# Tx power, Rx sensitivity

ms-height 5 ft

# modeled losses

loss 2		# duplexer and cable at BTS
loss 2		# user body
loss 7.5	# margin