FreeCalypso > hg > fc-magnetite
view cdg-hybrid/sap/8010_136_SIMDRV_SAP.pdf @ 265:0aa748b6413a
src/cs/system/Main/init.c: initial import from LoCosto source
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Sat, 05 Aug 2017 02:02:16 +0000 |
parents | e7a67accfad9 |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : 8010_136_simdrv_sap.pdf ;*** Creation : Wed Mar 11 09:57:50 CST 2009 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : 8010_136_simdrv_sap ;*** Document No. : 8010.136.03.009 ;*** Document Date : 2004-06-10 ;*** Document Status: BEING_PROCESSED ;*** Document Author: FDU ;******************************************************************************** PRAGMA SRC_FILE_TIME "Thu Nov 29 09:27:56 2007" PRAGMA LAST_MODIFIED "2004-06-10" PRAGMA ID_AND_VERSION "8010.136.03.009" PRAGMA PREFIX SIMDRV ; Prefix for this document PRAGMA ALLWAYS_ENUM_IN_VAL_FILE YES ; Adds enumerations in the .val file. PRAGMA ENABLE_GROUP YES ; Enable h-file grouping PRAGMA COMPATIBILITY_DEFINES NO ; Compatible to the old #defines CONST SIZE_ATR_INFO 0x21 ; The maximum length of the data returned from the ATR procedure GROUP uicc CONST MIN_RESULT 0x01 ; Minimum size of the response of any given command GROUP uicc CONST MAX_RESULT 0x100 ; Maximum size of the response of any given command GROUP uicc CONST MIN_DATA_SIZE 0x01 ; Minimum length of a data element GROUP uicc CONST MAX_DATA_SIZE 0xFF ; Maximum length of a data element GROUP uicc CONST MAX_READERS 0x02 ; Maximum number of card readers supported. GROUP uicc VALTAB VAL_reset_return_val GROUP uicc VAL 0 SIM_INSERTED "A SIM is inserted and ATR/PPS was successful" VAL 1 SIM_NOT_INSERTED "No SIM inserted (hardware detected)" VAL 2 INVALID_CARD "Card is not responding or gives unintelligible answers, communications time out." VAL 3 ME_FAILURE "Power management related problems, e.g. voltage selection" VAL 4 IMPROPER_CALL_BACK "simdrv_register function called with pointer improperly set, e.g. NULL." VAL 5 ME_READER_NOT_AVAILABLE "The reader requested is not available" VALTAB VAL_len GROUP uicc VAL 0x00 - 0x100 "Range of Length of Data" VAL 0xFFFF LENGTH_UNKNOWN "Indicating that the length expected is unknown." VALTAB VAL_sw1_2 GROUP uicc VAL 0x0001 ERR_NOCARD "No SIM inserted (hardware detected)" VAL 0x0002 ERR_NOT_RESET "A reset has not been performed on the driver with the requested Id." VAL 0x0003 ERR_ME_FAIL "Unrecoverable ME failure (for instance interrupt fails to occur)" VAL 0x0004 ERR_RETRY_FAIL "ME/SIM communication failed after certain retries, SIM reset required" VAL 0x0005 ERR_PARAM_WRONG "A driver function is called with invalid parameters" VALTAB VAL_cla GROUP uicc VAL 0xA0 GSM_CLASS_BYTE "GSM Class byte according to [GSM 11.11 / 3GPP 51.011]" VAL 0x80 UMTS_CLASS_BYTE "UMTS Class byte according to [ETSI 102 221 10.1.2]" VAL 0x00 UICC_CLASS_BYTE "UICC Class byte according to [ISO 7816-4]" VALTAB VAL_ins GROUP uicc VAL 0xA4 INS_SELECT "Select Instruction" VAL 0xF2 INS_STATUS "Status Instruction" VAL 0xB0 INS_READ_BINARY "Read Binary Instruction" VAL 0xD6 INS_UPDATE_BINARY "Update Binary Instruction" VAL 0xB2 INS_READ_RECORD "Read Record Instruction" VAL 0xDC INS_UPDATE_RECORD "Update Record Instruction" VAL 0xA2 INS_SEEK "Seek Instruction" VAL 0x32 INS_INCREASE "Increase Instruction" VAL 0x20 INS_VERIFY_CHV "Verify Chv Instruction" VAL 0x24 INS_CHANGE_CHV "Change Chv Instruction" VAL 0x26 INS_DISABLE_CHV "Disable Chv Instruction" VAL 0x28 INS_ENABLE_CHV "Ensable Chv Instruction" VAL 0x2C INS_UNBLOCK_CHV "Unblock Chv Instruction" VAL 0x04 INS_INVALIDATE "Invalidate Instruction" VAL 0x44 INS_REHABILITATE "Rehabilitate Instruction" VAL 0x88 INS_AUTHENTICATE "Run GSM Algorithm (2/2.5G) / Authenticate (3G) Instruction" VAL 0x10 INS_TERMINAL_PROFILE "Terminal Profile Instruction" VAL 0xC2 INS_ENVELOPE "Envelope Instruction" VAL 0x12 INS_FETCH "Fetch Instruction" VAL 0x14 INS_TERMINAL_RESPONSE "Terminal Response Instruction" VAL 0xC0 INS_GET_RESPONSE "Get Response Instruction" VALTAB VAL_voltage_select GROUP uicc VAL 0 REQ_VOLTAGE_SEL "The SIM reader driver shall perform voltage selection" VAL 1 OMIT_VOLTAGE_SEL "The SIM reader driver shall restart with the current voltage" VALTAB VAL_config_requested GROUP uicc VAL 0x00 OMIT_CONFIG_CHARACTERISTICS "PS Shall not retrieve Configuration Characteristics" VAL 0x01 REQUEST_CONFIG_CHARACTERISTICS "PS Shall retrieve Configuration Characteristics" VALTAB VAL_reader_id GROUP uicc VAL 01 - MAX_READERS "Range of Id's of readers" VAR insert_ptr "insert pointer" L GROUP uicc VAR remove_ptr "remove pointer" L GROUP uicc VAR atr_string "SIM Card Answer to reset string" B GROUP uicc VAR reset_return_val "Reset return value" B GROUP uicc VAL @p_8010_136_simdrv_sap - VAL_reset_return_val@ VAR result "Result byte" B GROUP uicc VAR len "Maximum length of expected data" S GROUP uicc VAL @p_8010_136_simdrv_sap - VAL_len@ VAR data "Data element" B GROUP uicc VAR sw1_2 "Status Words" S GROUP uicc VAL @p_8010_136_simdrv_sap - VAL_sw1_2@ VAR cla "Class Byte" B GROUP uicc VAL @p_8010_136_simdrv_sap - VAL_cla@ VAR ins "instruction code" B GROUP uicc VAL @p_8010_136_simdrv_sap - VAL_ins@ VAR voltage_select "Perform Voltage Selection" B GROUP uicc VAL @p_8010_136_simdrv_sap - VAL_voltage_select@ VAR p1 "Parameter 1 of the SIM APDU" B GROUP uicc VAR p2 "Parameter 2 of the SIM APDU" B GROUP uicc VAR config_requested "Configuration Characteristics requested" B GROUP uicc VAL @p_8010_136_simdrv_sap - VAL_config_requested@ VAR reader_id "Reader Id" B GROUP uicc VAL @p_8010_136_simdrv_sap - VAL_reader_id@ VAR uicc_characteristics "UICC Characteristics" B GROUP uicc COMP atr_string_info "SIM Card Info" GROUP uicc { atr_string [2..SIZE_ATR_INFO] ; SIM Card Answer to reset string } COMP result_info "Result Buffer" GROUP uicc { len ; Length of expected data result DYN[MIN_RESULT..MAX_RESULT] ; Result byte } COMP data_info "Data element info" GROUP uicc { data DYN[MIN_DATA_SIZE..MAX_DATA_SIZE] ; Data element } COMP cmd_header "Transparent command header" GROUP uicc { cla ; Class Byte value ins ; Instruction Code p1 ; Parameter P1 p2 ; Parameter P2 } COMP config_characteristics "Configuration Characteristics" GROUP uicc { uicc_characteristics ; UICC Characteristics } ; SIMDRV_DUMMY 0x80FF009A PRIM SIMDRV_DUMMY 0x80FF009A GROUP uicc { atr_string_info PTR ; SIM Card Info reset_return_val ; Return Value result_info PTR ; Result Buffer len ; Length of expected data data_info PTR ; Update Data Element sw1_2 ; Status Words cla ; Class Byte ins ; Instruction Code cmd_header ; Transparent command header voltage_select ; Perform Voltage Selection p1 ; SIM Command Parameters p2 ; SIM Command Parameters config_requested ; Configuration Characteristics requested config_characteristics PTR ; Configuration Characteristics reader_id ; Reader Id uicc_characteristics ; UICC Characteristics }